Diagnostic testing for Graves' or non-Graves' hyperthyroidism: A comparison of two thyrotropin receptor antibody immunoassays with thyroid scintigraphy and ultrasonography.

Lorenzo Scappaticcio1,2, Pierpaolo Trimboli2, Franco Keller3, Mauro Imperiali3, Arnoldo Piccardo4, Luca Giovanella2,3,5.   

Abstract

OBJECTIVE: Graves' disease (GD) is the most common cause of hyperthyroidism. In many cases, when the aetiological diagnosis of GD is not evident based on the clinical evaluation and thyroid function testing, it may become challenging to distinguish Graves' hyperthyroidism from other forms of thyrotoxicosis. The current study was primarly carried out to compare the diagnostic effectiveness of two TSH receptor antibody immunoassays (IMAs), ultrasonography and thyroid scintigraphy in hyperthyroidism scenario.
METHODS: We retrospectively analysed consecutive patients with newly diagnosed and untreated thyrotoxicosis who underwent thyroid functional tests, both TRAb and TSI measurements, thyroid scintigraphy and ultrasonography. TRAb assessment was carried out by Kryptor® compact PLUS, while TSI by Immulite® . Echo pattern 3 corresponded to 'thyroid inferno', and the final diagnosis of GD vs non-Graves' hyperthyroidism was made according to the thyroid scan (qualitative scintigraphy). Receiver operating characteristic (ROC) curves were drawn using the final diagnosis as reference. Clinical sensitivity and specificity, accuracy, positive predictive value (PPV) and negative predictive value (NPV) were calculated for all the tests.
RESULTS: A total of 124 untreated hyperthyroid patients were included in our study (GD, n = 86 vs non-Graves' hyperthyroidism, n = 38). ROC curves showed that the optimal cut-off values associated with the highest diagnostic sensitivity and specificity was 0.7 IU/L for TRAb Kryptor® (93 [85.4-97.4] and 86.8 [71.9-95.5]) and 0.1 IU/L for TSI Immulite® (94.2 [86.9-98.1] and 84.2 [68.7-93.9]), respectively. For the echo pattern 3, we found a good sensitivity (92.1%) and a high PPV (95.2%) but a quite low specificity value (69.8%) and a relative low NPV (57.5%). For thyroid scintigraphy, the TcTU cut-off value of 1.3% corresponded to the best limit for sensitivity and specificity in our patients (95.3 [88.5-98.7] and 96.4 [81.6-99.4]). The Passing-Bablok regression equation and the Bland-Altman test showed a great degree of correlation and agreement existed between TRAb Kryptor® and Immulite® TSI results.
CONCLUSIONS: Thyroid scintigraphy remains the most accurate method to differentiate causes of thyrotoxicosis. However, TRAb assays can be alternatively adopted in this setting, limiting the use of thyroid scintigraphy (TcTU evaluation) to TRAb-negative patients. Thyoid US is less accurate than both TRAb/TSI and thyroid scintigraphy, but the 'thyroid inferno' pattern provides a high PPV for GD.
© 2019 John Wiley & Sons Ltd.

Entities:  

Keywords:  hyperthyroidism; thyroid scintigraphy; thyroid ultrasonography; thyroid-stimulating immunoglobulins (TSI); thyrotropin receptor antibodies (TRAb)

Mesh:

Substances:

Year:  2019        PMID: 31742747     DOI: 10.1111/cen.14130

Source DB:  PubMed          Journal:  Clin Endocrinol (Oxf)        ISSN: 0300-0664            Impact factor:   3.478


  11 in total

1.  Thyroid dysfunction in Greece: Results from the national health examination survey EMENO.

Authors:  Paraskevi V Voulgari; Aliki I Venetsanopoulou; Natasa Kalpourtzi; Magda Gavana; Apostolos Vantarakis; Christos Hadjichristodoulou; Grigoris Chlouverakis; Grigoris Trypsianis; Yannis Alamanos; Giota Touloumi
Journal:  PLoS One       Date:  2022-03-04       Impact factor: 3.240

2.  TSH Receptor Antibodies (TRAb) Assay: An Underutilized Test in India.

Authors:  Jubbin Jagan Jacob
Journal:  Indian J Endocrinol Metab       Date:  2022-04-27

3.  Thyrotropin receptor antibody immunoassays may not be reliable in confirming diagnosis of Painless Thyroiditis.

Authors:  D Sanyal; S Chatterjee
Journal:  Acta Endocrinol (Buchar)       Date:  2020 Oct-Dec       Impact factor: 0.877

4.  A rare simultaneous manifestation of polyglandular autoimmune syndrome type II.

Authors:  Michael Dick; Michael Croxson
Journal:  Endocrinol Diabetes Metab Case Rep       Date:  2020-07-29

5.  Deep learning for intelligent diagnosis in thyroid scintigraphy.

Authors:  Tingting Qiao; Simin Liu; Zhijun Cui; Xiaqing Yu; Haidong Cai; Huijuan Zhang; Ming Sun; Zhongwei Lv; Dan Li
Journal:  J Int Med Res       Date:  2021-01       Impact factor: 1.671

6.  The prognostic value of thyroid-stimulating immunoglobulin in the management of Graves' disease.

Authors:  Yulin Zhou; Mengxi Zhou; Yicheng Qi; Weiqing Wang; Xinxin Chen; Shu Wang
Journal:  Ther Adv Endocrinol Metab       Date:  2021-09-28       Impact factor: 3.565

7.  The Prediction Model Using Thyroid-stimulating Immunoglobulin Bioassay For Relapse of Graves' Disease.

Authors:  Han-Sang Baek; Jaejun Lee; Chai-Ho Jeong; Jeongmin Lee; Jeonghoon Ha; Kwanhoon Jo; Min-Hee Kim; Jae Hyoung Cho; Moo Il Kang; Dong-Jun Lim
Journal:  J Endocr Soc       Date:  2022-02-16

8.  Duplex Hemodynamic Parameters of Both Superior and Inferior Thyroid Arteries in Evaluation of Thyroid Hyperfunction Disorders.

Authors:  Maha Assem Hussein; Alaa Abdel Hamid; Rasha M Abdel Samie; Elshaymaa Hussein; Shereen Sadik Elsawy
Journal:  Int J Gen Med       Date:  2022-09-09

9.  Clinical evaluation of an automated TSI bridge immunoassay in the diagnosis of Graves' disease and its relationship to the degree of hyperthyroidism.

Authors:  Tianqi Liu; Xiuying Zhang; Li Long; Lingli Zhou; Jing Chen; Meng Li; Ying Gao; Xianghai Zhou; Xueyao Han; Linong Ji
Journal:  BMC Endocr Disord       Date:  2022-08-31       Impact factor: 3.263

10.  Evaluation of Children and Adolescents with Thyroid Nodules: A Single Center Experience

Authors:  Selin Elmaoğulları; Şervan Özalkak; Semra Çetinkaya; İbrahim Karaman; Çiğdem Üner; Nilüfer Arda; Şenay Savaş-Erdeve; Zehra Aycan
Journal:  J Clin Res Pediatr Endocrinol       Date:  2020-12-30
View more