Literature DB >> 31736309

Dual-Mode Electrochemical Assay of Prostate-Specific Antigen Based on Antifouling Peptides Functionalized with Electrochemical Probes and Internal References.

Caifeng Ding1, Xinyan Wang1, Xiliang Luo1.   

Abstract

Sensitive and selective detection of target analytes in complex biological samples is currently a major challenge. Herein we constructed a dual-mode antifouling electrochemical sensing platform for the detection of prostate-specific antigen (PSA) based on two kinds of antifouling peptides functionalized with a graphene oxide-Fe3O4-thionine (GO-Fe3O4-Thi) probe and internal reference ferrocene (Fc), respectively. The longer peptide (Pep1) modified with the GO-Fe3O4-Thi probe was designed to contain a peptide sequence (HSSKLQK) capable of being recognized and cut by PSA. The GO-Fe3O4-Thi probe functions not only as a peroxidase mimick (GO-Fe3O4) but also works as an electrochemical probe due to the presence of thionine (Thi). The concentration of PSA can be measured through both the increase of differential pulse voltammetry (DPV) signal change of Thi and the decrease of chronoamperometry (CA) signal of the reduction of H2O2 electrocatalyzed by GO-Fe3O4. The shorter peptide (Pep2) was tagged with Fc, whose DPV signal remained constant and was independent of the presence of PSA, and it was used as an internal reference to ensure the reliability and accuracy of the measurement. The dual-mode PSA sensor exhibits a wide linear range from 5 pg/mL to 10 ng/mL, with low detection limits of 0.76 and 0.42 pg/mL through DPV and CA modes, respectively. More importantly, owing to the antifouling capability of the designed peptides, the biosensor performances remained operable even in human serum, indicating feasibility of the electrochemical biosensor for practical PSA quantification in complex samples.

Entities:  

Year:  2019        PMID: 31736309     DOI: 10.1021/acs.analchem.9b04206

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  3 in total

Review 1.  Electrochemical nanobiosensors equipped with peptides: a review.

Authors:  Masoud Negahdary; Lúcio Angnes
Journal:  Mikrochim Acta       Date:  2022-02-08       Impact factor: 5.833

2.  Electrochemical Biosensor with Enhanced Antifouling Capability for COVID-19 Nucleic Acid Detection in Complex Biological Media.

Authors:  Zhen Song; Yihui Ma; Min Chen; Adriano Ambrosi; Caifeng Ding; Xiliang Luo
Journal:  Anal Chem       Date:  2021-04-02       Impact factor: 6.986

Review 3.  The Role of Peptides in the Design of Electrochemical Biosensors for Clinical Diagnostics.

Authors:  Patrick Severin Sfragano; Giulia Moro; Federico Polo; Ilaria Palchetti
Journal:  Biosensors (Basel)       Date:  2021-07-23
  3 in total