Literature DB >> 3173064

Rapid 31P spectroscopy on a 4-T whole-body system.

C J Hardy1, P A Bottomley, P B Roemer, R W Redington.   

Abstract

Initial 31P spectroscopy results from a 4-T whole-body system are reported. Localized spectra from the human head, liver, and calf were obtained using DRESS, slice-interleaved DRESS, and volume 3DFT spectroscopic imaging techniques. Substantial reductions in data acquisition times to 10 s-4 min were achieved relative to previous similar experiments at 1.5 T. Some gain in spectral resolution (as measured in ppm) was also realized in the head.

Entities:  

Mesh:

Year:  1988        PMID: 3173064     DOI: 10.1002/mrm.1910080113

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  9 in total

Review 1.  [Clinical MR at 3 Tesla: current status].

Authors:  K T Baudendistel; J T Heverhagen; M V Knopp
Journal:  Radiologe       Date:  2004-01       Impact factor: 0.635

2.  In vivo 31P MRS of human brain at high/ultrahigh fields: a quantitative comparison of NMR detection sensitivity and spectral resolution between 4 T and 7 T.

Authors:  Hongyan Qiao; Xiaoliang Zhang; Xiao-Hong Zhu; Fei Du; Wei Chen
Journal:  Magn Reson Imaging       Date:  2006-10-04       Impact factor: 2.546

3.  A prototype RF dosimeter for independent measurement of the average specific absorption rate (SAR) during MRI.

Authors:  John P Stralka; Paul A Bottomley
Journal:  J Magn Reson Imaging       Date:  2007-11       Impact factor: 4.813

4.  The intrinsic signal-to-noise ratio in human cardiac imaging at 1.5, 3, and 4 T.

Authors:  H Wen; T J Denison; R W Singerman; R S Balaban
Journal:  J Magn Reson       Date:  1997-03       Impact factor: 2.229

Review 5.  Magnetic resonance spectroscopy in metabolic and molecular imaging and diagnosis of cancer.

Authors:  Kristine Glunde; Dmitri Artemov; Marie-France Penet; Michael A Jacobs; Zaver M Bhujwalla
Journal:  Chem Rev       Date:  2010-05-12       Impact factor: 60.622

6.  Considerations in applying compressed sensing to in vivo phosphorus MR spectroscopic imaging of human brain at 3T.

Authors:  Gokce Hale Hatay; Muhammed Yildirim; Esin Ozturk-Isik
Journal:  Med Biol Eng Comput       Date:  2016-11-08       Impact factor: 2.602

7.  The design and test of a new volume coil for high field imaging.

Authors:  H Wen; A S Chesnick; R S Balaban
Journal:  Magn Reson Med       Date:  1994-10       Impact factor: 4.668

Review 8.  Advanced In Vivo Heteronuclear MRS Approaches for Studying Brain Bioenergetics Driven by Mitochondria.

Authors:  Xiao-Hong Zhu; Fei Du; Nanyin Zhang; Yi Zhang; Hao Lei; Xiaoliang Zhang; Hongyan Qiao; Kamil Ugurbil; Wei Chen
Journal:  Methods Mol Biol       Date:  2009

9.  Field dependence study of in vivo brain (31) P MRS up to 16.4 T.

Authors:  Ming Lu; Wei Chen; Xiao-Hong Zhu
Journal:  NMR Biomed       Date:  2014-07-28       Impact factor: 4.044

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.