Literature DB >> 31724097

5-0 Polypropylene versus 5-0 fast absorbing plain gut for cutaneous wound closure: a randomized evaluator blind trial.

Daniel Brian Eisen1, Anne Rang Zhuang2,3, Aliza Hasan4, Victoria Rose Sharon5, Heejung Bang6, Milene Kennedy Crispin7,8.   

Abstract

Mixed opinions exist regarding cosmetic outcomes of 5-0 fast absorbing plain (FG) gut relative to nonabsorbable suture material, such as 5-0 polypropylene (PP). High quality randomized trials comparing these two suture materials are lacking. To determine whether the use of PP during layered repair of linear cutaneous surgery wounds improves scar cosmesis compared to wound closure with FG. A randomized, split wound, comparative effectiveness trial was undertaken. Patients were evaluated 3 months after the intervention by two blinded physicians using the validated patient observer scar assessment scale (POSAS). Patient assessments were also captured using the same instrument as well as scar width and complications. The mean sum of the six components of the POSAS was 10.26 vs 12.74 for PP and FG, respectively, significantly (p < 0.001) in favor of PP. Mean observer overall opinion similarly showed better outcomes for PP than for FG [1.88 vs 2.52, respectively (p < 0.006)]. The mean sum of the patient assessed components of the POSAS for PP and FG was 12.3 vs 14.34, respectively (p = 0.11). Patient overall opinion significantly favored PP (2.41 vs 3.14, p = 0.043). PP resulted in small but statistically significant better cosmetic outcomes than FG. Pain experienced during suture removal was minimal for most patients.

Entities:  

Keywords:  Cosmetic outcome; Fast absorbing gut; Polypropylene; Suture material

Year:  2019        PMID: 31724097      PMCID: PMC7192227          DOI: 10.1007/s00403-019-02009-5

Source DB:  PubMed          Journal:  Arch Dermatol Res        ISSN: 0340-3696            Impact factor:   3.017


  19 in total

1.  Buried vertical mattress suture.

Authors:  J A Zitelli; R L Moy
Journal:  J Dermatol Surg Oncol       Date:  1989-01

2.  Effect of Adhesive Strips and Dermal Sutures vs Dermal Sutures Only on Wound Closure: A Randomized Clinical Trial.

Authors:  Trenton Custis; April W Armstrong; Thomas H King; Victoria R Sharon; Daniel B Eisen
Journal:  JAMA Dermatol       Date:  2015-08       Impact factor: 10.282

3.  Statistics in medicine--reporting of subgroup analyses in clinical trials.

Authors:  Rui Wang; Stephen W Lagakos; James H Ware; David J Hunter; Jeffrey M Drazen
Journal:  N Engl J Med       Date:  2007-11-22       Impact factor: 91.245

4.  A comparison of absorbable and nonabsorbable suture materials for skin repair.

Authors:  B Guyuron; C Vaughan
Journal:  Plast Reconstr Surg       Date:  1992-02       Impact factor: 4.730

5.  Research electronic data capture (REDCap)--a metadata-driven methodology and workflow process for providing translational research informatics support.

Authors:  Paul A Harris; Robert Taylor; Robert Thielke; Jonathon Payne; Nathaniel Gonzalez; Jose G Conde
Journal:  J Biomed Inform       Date:  2008-09-30       Impact factor: 6.317

6.  Systematic review of absorbable vs non-absorbable sutures used for the closure of surgical incisions.

Authors:  Muhammad S Sajid; Malcolm R McFall; Pauline A Whitehouse; Parv S Sains
Journal:  World J Gastrointest Surg       Date:  2014-12-27

7.  Optimizing closure materials for upper lid blepharoplasty: a randomized, controlled trial.

Authors:  David J Kouba; Emily Tierney; Bassel H Mahmoud; Denise Woo
Journal:  Dermatol Surg       Date:  2010-12-28       Impact factor: 3.398

8.  Comparison of Running Cutaneous Suture Spacing During Linear Wound Closures and the Effect on Wound Cosmesis of the Face and Neck: A Randomized Clinical Trial.

Authors:  Lindsay R Sklar; Aunna Pourang; April W Armstrong; Simran K Dhaliwal; Raja K Sivamani; Daniel B Eisen
Journal:  JAMA Dermatol       Date:  2019-03-01       Impact factor: 10.282

9.  Reliable and feasible evaluation of linear scars by the Patient and Observer Scar Assessment Scale.

Authors:  Annekatrien L van de Kar; Leonard U M Corion; Mark J C Smeulders; Lieneke J Draaijers; Chantal M A M van der Horst; Paul P M van Zuijlen
Journal:  Plast Reconstr Surg       Date:  2005-08       Impact factor: 4.730

10.  CONSORT 2010 statement: extension checklist for reporting within person randomised trials.

Authors:  Nikolaos Pandis; Bryan Chung; Roberta W Scherer; Diana Elbourne; Douglas G Altman
Journal:  BMJ       Date:  2017-06-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.