The TES beamline (8-BM) at NSLS-II: tender-energy spatially resolved X-ray absorption spectroscopy and X-ray fluorescence imaging.

Paul Northrup1.   

Abstract

The tender-energy X-ray spectroscopy (TES) beamline at the National Synchrotron Light Source II (NSLS-II) is now operational for general users. Its scientific mission includes static and in situ X-ray fluorescence imaging and spatially resolved X-ray absorption spectroscopy for characterization of complex heterogeneous, structured and dynamic natural or engineered materials and systems. TES is optimized for the tender-energy range, offering routine operations from 2.0 to 5.5 keV, with capabilities to reach down to 1.2 or up to 8 keV with configuration change. TES is designed as an extended X-ray absorption fine-structure microprobe (EXAFS microprobe) for applications of micrometre-scale EXAFS spectroscopy to heterogeneous samples. Beam size is user-tunable from ∼2 to 25 µm. Energy may be scanned on-the-fly or in traditional step scanning. Importantly, the position of the microbeam at the sample location does not move significantly during energy scanning or when changing energy across the entire routine energy range. This enables full EXAFS of a particle or domain the same size as the probe beam, and measurement of the same spot at different energies. In addition, there is no measureable drift in energy calibration (repeatability) scan-to-scan and over 24 h. This is critical where simultaneous calibration measurements are generally not feasible, and for speciation mapping where precise and stable control of incident energy is essential. The sample environment is helium atmosphere at room pressure with infrastructure for in situ electrochemistry and catalysis in small sample cells or microreactors. As the first bend-magnet beamline at NSLS-II, noteworthy commissioning aspects are described. Example measurements are presented to illustrate its capabilities.

Keywords:  EXAFS; NSLS-II; XANES; XRF microprobes; in situ XAS; microbeam XAS; tender energy

Year:  2019        PMID: 31721752     DOI: 10.1107/S1600577519012761

Source DB:  PubMed          Journal:  J Synchrotron Radiat        ISSN: 0909-0495            Impact factor:   2.616


  3 in total

1.  Spatially separating redox centers on 2D carbon nitride with cobalt single atom for photocatalytic H2O2 production.

Authors:  Chiheng Chu; Qianhong Zhu; Zhenhua Pan; Srishti Gupta; Dahong Huang; Yonghua Du; Seunghyun Weon; Yueshen Wu; Christopher Muhich; Eli Stavitski; Kazunari Domen; Jae-Hong Kim
Journal:  Proc Natl Acad Sci U S A       Date:  2020-03-11       Impact factor: 11.205

2.  Exploring spectroscopic X-ray nano-imaging with Zernike phase contrast enhancement.

Authors:  Yeseul Kim; Jun Lim
Journal:  Sci Rep       Date:  2022-02-21       Impact factor: 4.379

3.  A new Kirkpatrick-Baez-based scanning microscope for the Submicron Resolution X-ray Spectroscopy (SRX) beamline at NSLS-II.

Authors:  E Nazaretski; D S Coburn; W Xu; J Ma; H Xu; R Smith; X Huang; Y Yang; L Huang; M Idir; A Kiss; Y S Chu
Journal:  J Synchrotron Radiat       Date:  2022-07-29       Impact factor: 2.557

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.