Literature DB >> 31720866

An integrated measurement of six response performance indicators for lead ion-selective electrodes and application.

Lingzhi Sun1, Chengjun Sun2, Xianxiang Sun3.   

Abstract

A heavy metal ion-selective electrode (ISE) with highly multiple response performances, rather than a high single response performance, is needed urgently for in situ, real-time environmental monitoring. In this study, we present an integrated measurement of six response performance variables such as the response slope, selectivity, dynamical range, detection limit, response time, and lifetime. They are selected and used as the indicators of the quality assessment for Pb2+-ISEs. The measurement, named as electrode comprehensive quality index (IECQ), is a single number for a given ISE. The comprehensive qualities of 114 Pb2+-ISEs reported in the literature were evaluated through the index method. Twenty-one Pb2+-ISEs-based polymer membrane with top 3 IECQ values for seven different properties have been recommended by evaluating and screening of the electrodes. Five Pb2+-ISEs-based polymer membrane with the best single response performance were also provided. The recommended Pb2+-ISEs, along with the corresponding Pb2+-ISEs with the miniaturized configurations, will provide helpful guideline for the application of Pb2+-ISE with highly multiple response performances in real-time environmental monitoring.

Entities:  

Keywords:  Comprehensive quality index; Environmental monitoring; Lead ion-selective electrode; Overall quality evaluation; Screening

Mesh:

Substances:

Year:  2019        PMID: 31720866     DOI: 10.1007/s10661-019-7908-z

Source DB:  PubMed          Journal:  Environ Monit Assess        ISSN: 0167-6369            Impact factor:   2.513


  18 in total

1.  Lifetime of ion-selective electrodes based on charged ionophores

Authors: 
Journal:  Anal Chem       Date:  2000-04-15       Impact factor: 6.986

2.  Electrochemical sensors for environmental monitoring: design, development and applications.

Authors:  Grady Hanrahan; Deepa G Patil; Joseph Wang
Journal:  J Environ Monit       Date:  2004-06-28

3.  Lead(II)-selective ionophores for ion-selective electrodes: a review.

Authors:  Marcin Guziński; Grzegorz Lisak; Justyna Kupis; Artur Jasiński; Maria Bocheńska
Journal:  Anal Chim Acta       Date:  2013-05-02       Impact factor: 6.558

4.  Health risk assessment of heavy metals via dietary intake of foodstuffs from the wastewater irrigated site of a dry tropical area of India.

Authors:  Anita Singh; Rajesh Kumar Sharma; Madhoolika Agrawal; Fiona M Marshall
Journal:  Food Chem Toxicol       Date:  2009-11-24       Impact factor: 6.023

5.  Preparation and analytical application of the novel Hg(II)-selective membrane electrodes based on oxime compounds.

Authors:  Tugba Sardohan-Koseoglu; Esengul Kir; Bulent Dede
Journal:  J Colloid Interface Sci       Date:  2014-12-26       Impact factor: 8.128

6.  Electrochemical Analysis of Some Toxic Metals by Ion-Selective Electrodes.

Authors:  Vinod K Gupta; M R Ganjali; P Norouzi; H Khani; Arunima Nayak; Shilpi Agarwal
Journal:  Crit Rev Anal Chem       Date:  2011 Oct-Dec       Impact factor: 6.535

7.  Polymeric plasticizer extends the lifetime of PVC-membrane ion-selective electrodes.

Authors:  Elsayed M Zahran; Andrea New; Vasilis Gavalas; Leonidas G Bachas
Journal:  Analyst       Date:  2013-12-18       Impact factor: 4.616

8.  A mercury(II) selective sensor based on N,N'-bis(salicylaldehyde)-phenylenediamine as neutral carrier for potentiometric analysis in water samples.

Authors:  Hazem M Abu-Shawish
Journal:  J Hazard Mater       Date:  2009-01-16       Impact factor: 10.588

9.  A solid-contact ion selective electrode for copper(II) using a succinimide derivative as ionophore.

Authors:  Mihaela Dana Tutulea-Anastasiu; Deivy Wilson; Manel del Valle; Cristina Mihaela Schreiner; Igor Cretescu
Journal:  Sensors (Basel)       Date:  2013-04-02       Impact factor: 3.576

Review 10.  Recent trends in monitoring of European water framework directive priority substances using micro-sensors: a 2007-2009 review.

Authors:  Philippe Namour; Mathieu Lepot; Nicole Jaffrezic-Renault
Journal:  Sensors (Basel)       Date:  2010-08-26       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.