Polymeric plasticizer extends the lifetime of PVC-membrane ion-selective electrodes.

Elsayed M Zahran1, Andrea New, Vasilis Gavalas, Leonidas G Bachas.   

Abstract

The nature of the plasticizer plays a pivotal role in the analytical performance of polymer membrane ion sensors. Conventional plasticizers suffer leaching or migration from the membrane and exudation, both of which could limit the lifetime of sensors based on plasticized membranes. Herein, we describe the use of polyester sebacate (PES), a model polymeric plasticizer, in the preparation of poly (vinyl chloride) (PVC) membrane ion-selective electrodes (ISEs) using valinomycin as ionophore. PVC membrane electrodes plasticized with polyester sebacate demonstrated potentiometric response characteristics that compared favorably to ones plasticized with the conventional and similarly structured plasticizer bis(2-ethylhexyl) sebacate (DOS). Increasing the content of polyester sebacate in the membrane enhanced the response and improved the selectivity of valinomycin-based ISEs toward potassium over sodium. Various methods, including electrochemical impedance spectroscopy, UV-vis spectroscopy, dark field optical microscopy, and potentiometry were employed to study the effect of plasticizer on the leaching of the membrane components and the lifetime of both DOS- and PES-plasticized membranes. PES-plasticized electrodes maintained Nernstian response and high selectivity for more than four months, an improvement over DOS-plasticized membrane electrodes. This was attributed to enhanced retention of the membrane components because of the high polymeric nature of the polyester sebacate. These characteristics suggest that polyester sebacate is a good candidate to replace the conventional plasticizers in preparing PVC membrane electrodes with longer lifetime.

Entities:  

Year:  2013        PMID: 24352534     DOI: 10.1039/c3an01963b

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  2 in total

1.  An integrated measurement of six response performance indicators for lead ion-selective electrodes and application.

Authors:  Lingzhi Sun; Chengjun Sun; Xianxiang Sun
Journal:  Environ Monit Assess       Date:  2019-11-13       Impact factor: 2.513

2.  The Influence of Plasticizers on the Response Characteristics of the Surfactant Sensor for Cationic Surfactant Determination in Disinfectants and Antiseptics.

Authors:  Nikola Sakač; Dubravka Madunić-Čačić; Maja Karnaš; Bojan Đurin; Ivan Kovač; Marija Jozanović
Journal:  Sensors (Basel)       Date:  2021-05-19       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.