Literature DB >> 31719736

Comparative evaluation of torque prescription of commercially available 018Roth and 022MBT PEA brands in maxillary anterior teeth.

Dinesh Chander Chaudhary1, Vineet Sharma2.   

Abstract

BACKGROUND: Torque is an important component of preadjusted edgewise prescriptions to achieve ideal/optimum tooth position and more so in aesthetics sensitive maxillary anterior teeth. Thus, the need to audit available commercial brands of 018Roth and 022MBT was felt and in vitro analysis of eight brands namely 3M Unitek, Dentaurum, d-tech, IMD Medical, Libral Leone, Modern Orthodontics, Ormco and Ortho Organizer, was carried out.
METHODS: The method involved perfect superimposition of two standardized images: one delineating facial axis of the tooth with stainless steel straight wire and other with full dimension arch wire engagement in bracket. The two images were superimposed and opacity of one of the images altered using Adobe Photoshop software to reveal the position of two wires. The angle obtained between two wires gave a direct read-out of torque expression. The comparison was statistically done with one-way ANOVA and Tukey's HSD test.
RESULTS: In 018Roth group, IMD Medical did not show any significant difference from the standard while comparison independent of standard showed that IMD, Modern Orthodontics and Ormco were not significantly different from each other. In 022MBT group, IMD Medical, d-tech, 3M Unitek and Modern Orthodontics did not have statistically significant difference from and independent of standard.
CONCLUSION: Significant variations from the standard values of both 018 Roth and 022 MBT exist in the market products and thus selection of product must be based on proper guidance in addition to clinical acumen/experience. Also the methodology provides easy to use, inexpensive set-up in the clinical settings.
© 2018 Published by Elsevier B.V. on behalf of Director General, Armed Forces Medical Services.

Entities:  

Keywords:  Maxillary anterior teeth; Standard experimental set-up; Standard prescription; Torque

Year:  2018        PMID: 31719736      PMCID: PMC6838513          DOI: 10.1016/j.mjafi.2018.03.007

Source DB:  PubMed          Journal:  Med J Armed Forces India        ISSN: 0377-1237


  14 in total

1.  Effect of variation in tooth morphology and bracket position on first and third order correction with preadjusted appliances.

Authors:  R R Miethke; B Melsen
Journal:  Am J Orthod Dentofacial Orthop       Date:  1999-09       Impact factor: 2.650

2.  Assessment of second-order clearances between orthodontic archwires and bracket slots via the critical contact angle for binding.

Authors:  R P Kusy; J Q Whitley
Journal:  Angle Orthod       Date:  1999-02       Impact factor: 2.079

3.  Loss of anterior torque control due to variations in bracket slot and archwire dimensions.

Authors:  R E Siatkowski
Journal:  J Clin Orthod       Date:  1999-09

4.  An evaluation of slot size in orthodontic brackets--are standards as expected?

Authors:  A C Cash; S A Good; R V Curtis; F McDonald
Journal:  Angle Orthod       Date:  2004-08       Impact factor: 2.079

5.  The straight-wire appliance. Explained and compared.

Authors:  L F Andrews
Journal:  J Clin Orthod       Date:  1976-03

6.  Anterior tooth morphology and its effect on torque.

Authors:  M van Loenen; J Degrieck; G De Pauw; L Dermaut
Journal:  Eur J Orthod       Date:  2005-06       Impact factor: 3.075

7.  Normal torque of the buccal surface of mandibular teeth and its relationship with bracket positioning: a study in normal occlusion.

Authors:  Marcelo Antonio Mestriner; Carla Enoki; José Nelson Mucha
Journal:  Braz Dent J       Date:  2006

8.  Influence of the convexity of the upper central incisor on the torque expression of preadjusted brackets.

Authors:  Julio Wilson Vigorito; Ricardo Moresca; Gladys Cristina Dominguez; André Tortamano
Journal:  J Clin Orthod       Date:  2006-01

9.  Orthodontics in 3 millennia. Chapter 16: Late 20th-century fixed appliances.

Authors:  Norman Wahl
Journal:  Am J Orthod Dentofacial Orthop       Date:  2008-12       Impact factor: 2.650

10.  The straight-wire appliance 17 years later.

Authors:  R H Roth
Journal:  J Clin Orthod       Date:  1987-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.