Literature DB >> 31714462

Is the Functional Threshold Power a Valid Metric to Estimate the Maximal Lactate Steady State in Cyclists?

José Ramón Lillo-Beviá1, Javier Courel-Ibáñez, Victor Cerezuela-Espejo, Ricardo Morán-Navarro, Alejandro Martínez-Cava, Jesús G Pallarés.   

Abstract

ABSTRACT: Lillo-Beviá, JR, Courel-Ibáñez, J, Cerezuela-Espejo, V, Morán-Navarro, R, Martínez-Cava, A, and Pallarés, JG. Is the functional threshold power a valid metric to estimate the maximal lactate steady state in cyclists? J Strength Cond Res 36(1): 167-173, 2022-The aims of this study were to determine (a) the repeatability of a 20-minute time-trial (TT20), (b) the location of the TT20 in relation to the main physiological events of the aerobic-anaerobic transition, and (c) the predictive power of a list of correction factors and linear/multiple regression analysis applied to the TT20 result to estimate the individual maximal lactate steady state (MLSS). Under laboratory conditions, 11 trained male cyclists and triathletes (V̇o2max 59.7 ± 3.0 ml·kg-1·min-1) completed a maximal graded exercise test to record the power output associated with the first and second ventilatory thresholds and V̇o2max measured by indirect calorimetry, several 30 minutes constant tests to determine the MLSS, and 2 TT20 tests with a short warm-up. Very high repeatability of TT20 tests was confirmed (standard error of measurement of ±3 W and smallest detectable change of ±9 W). Validity results revealed that MLSS differed substantially from TT20 (bias = 26 ± 7 W). The maximal lactate steady state was then estimated from the traditional 95% factor (bias = 12 ± 7 W) and a novel individual correction factor (ICF% = MLSS/TT20), resulting in 91% (bias = 1 ± 6 W). Complementary linear (MLSS = 0.7488 × TT20 + 43.24; bias = 0 ± 5 W) and multiple regression analysis (bias = 0 ± 4 W) substantially improved the individual MLSS workload estimation. These findings suggest reconsidering the TT20 procedures and calculations to increase the effectiveness of the MLSS prediction.
Copyright © 2019 National Strength and Conditioning Association.

Entities:  

Mesh:

Substances:

Year:  2022        PMID: 31714462     DOI: 10.1519/JSC.0000000000003403

Source DB:  PubMed          Journal:  J Strength Cond Res        ISSN: 1064-8011            Impact factor:   3.775


  3 in total

Review 1.  A critical review of critical power.

Authors:  Raffy Dotan
Journal:  Eur J Appl Physiol       Date:  2022-03-18       Impact factor: 3.346

2.  Three weeks of a home-based "sleep low-train low" intervention improves functional threshold power in trained cyclists: A feasibility study.

Authors:  Samuel Bennett; Eve Tiollier; Franck Brocherie; Daniel J Owens; James P Morton; Julien Louis
Journal:  PLoS One       Date:  2021-12-02       Impact factor: 3.240

3.  Time to Exhaustion at the Respiratory Compensation Point in Recreational Cyclists.

Authors:  Susana Moral-González; Javier González-Sánchez; Pedro L Valenzuela; Sonia García-Merino; Carlos Barbado; Alejandro Lucia; Carl Foster; David Barranco-Gil
Journal:  Int J Environ Res Public Health       Date:  2020-08-31       Impact factor: 3.390

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.