Literature DB >> 31708696

Effective Reduction of Radiation Exposure during Cardiac Catheterization.

Alejandro Gutiérrez-Barrios, Hugo Camacho-Galán, Francisco Medina-Camacho, Dolores Cañadas-Pruaño, Antonio Jimenez-Moreno, German Calle-Perez, Rafael Vázquez-García.   

Abstract

Exposure to ionizing radiation during cardiac catheterization can have harmful consequences for patients and for the medical staff involved in the procedures. Minimizing radiation doses during the procedures is essential. We investigated whether fine-tuning the radiation protocol reduces radiation doses in the cardiac catheterization laboratory. In January 2016, we implemented a new protocol with reduced radiation doses in the Hospital de Jerez catheterization laboratory. We analyzed 170 consecutive coronary interventional procedures (85 of which were performed after the new protocol was implemented) and the personal dosimeters of the interventional cardiologists who performed the procedures. Overall, the low-radiation protocol reduced air kerma (dose of radiation) by 44.9% (95% CI, 18.4%-70.8%; P=0.001). The dose-area product decreased by 61% (95% CI, 30.2%-90.1%; P <0.001) during percutaneous coronary interventions. We also found that the annual deep (79%, P=0.026) and shallow (62.2%, P=0.035) radiation doses to which primary operators were exposed decreased significantly under the low-radiation protocol. These dose reductions were achieved without increasing the volume of contrast media, fluoroscopy time, or rates of procedural complications, and without reducing the productivity of the laboratory. Optimizing the radiation safety protocol effectively reduced radiation exposure in patients and operators during cardiac catheterization procedures.
© 2019 by the Texas Heart® Institute, Houston.

Entities:  

Keywords:  Cardiac catheterization/adverse effects; occupational exposure/prevention & control; patient safety; radiation exposure/prevention & control; radiation monitoring; radiation protection/methods; radiography, interventional/adverse effects; risk factors; workforce

Mesh:

Year:  2019        PMID: 31708696      PMCID: PMC6827476          DOI: 10.14503/THIJ-17-6548

Source DB:  PubMed          Journal:  Tex Heart Inst J        ISSN: 0730-2347


  12 in total

Review 1.  Skin injuries from fluoroscopically guided procedures: part 2, review of 73 cases and recommendations for minimizing dose delivered to patient.

Authors:  T R Koenig; F A Mettler; L K Wagner
Journal:  AJR Am J Roentgenol       Date:  2001-07       Impact factor: 3.959

Review 2.  Optimizing Radiation Safety in the Cardiac Catheterization Laboratory: A Practical Approach.

Authors:  Georgios Christopoulos; Lorenza Makke; Georgios Christakopoulos; Anna Kotsia; Bavana V Rangan; Michele Roesle; Donald Haagen; Dharam J Kumbhani; Charles E Chambers; Samir Kapadia; Ehtisham Mahmud; Subhash Banerjee; Emmanouil S Brilakis
Journal:  Catheter Cardiovasc Interv       Date:  2015-11-03       Impact factor: 2.692

3.  ACCF/AHA/HRS/SCAI clinical competence statement on physician knowledge to optimize patient safety and image quality in fluoroscopically guided invasive cardiovascular procedures. A report of the American College of Cardiology Foundation/American Heart Association/American College of Physicians Task Force on Clinical Competence and Training.

Authors:  John W Hirshfeld; Stephen Balter; Jeffrey A Brinker; Morton J Kern; Lloyd W Klein; Bruce D Lindsay; Carl L Tommaso; Cynthia M Tracy; Louis K Wagner; Mark A Creager; Michael Elnicki; John W Hirshfeld; Beverly H Lorell; George P Rodgers; Cynthia M Tracy; Howard H Weitz
Journal:  J Am Coll Cardiol       Date:  2004-12-07       Impact factor: 24.094

Review 4.  Radiation in the cardiac catheter laboratory.

Authors:  John Partridge
Journal:  Heart       Date:  2005-12       Impact factor: 5.994

5.  Report of the Inter-Society Commission for Heart Disease Resources. Optimal resources for examination of the chest and cardiovascular system. A hospital planning and resource guideline. Radiologic facilities for conventional x-ray examination of the heart and lungs. Catheterization-angiographic Laboratories. Radiologic resources for cardiovascular surgical operating rooms and intensive care units.

Authors:  M P Judkins; H L Abrams; J D Bristow; E Carlsson; J M Criley; L P Elliott; K B Ellis; G C Friesinger; R H Greenspan; M Viamonte
Journal:  Circulation       Date:  1976-02       Impact factor: 29.690

Review 6.  Risk of cataract among interventional cardiologists and catheterization lab staff: A systematic review and meta-analysis.

Authors:  Ahmed Elmaraezy; Mostafa Ebraheem Morra; Abdelrhman Tarek Mohammed; Ahmed Al-Habaa; Ahmed Elgebaly; Ahmed Abdelmotaleb Ghazy; Adham M Khalil; Nguyen Tien Huy; Kenji Hirayama
Journal:  Catheter Cardiovasc Interv       Date:  2017-05-13       Impact factor: 2.692

7.  Radiation dose reduction in the cardiac catheterization laboratory utilizing a novel protocol.

Authors:  Anthony W A Wassef; Brett Hiebert; Amir Ravandi; John Ducas; Kunal Minhas; Minh Vo; Malek Kass; Gurpreet Parmar; Farrukh Hussain
Journal:  JACC Cardiovasc Interv       Date:  2014-04-16       Impact factor: 11.195

Review 8.  Radiation cataractogenesis: a review of recent studies.

Authors:  E A Ainsbury; S D Bouffler; W Dörr; J Graw; C R Muirhead; A A Edwards; J Cooper
Journal:  Radiat Res       Date:  2009-07       Impact factor: 2.841

9.  Determinants of operator and patient radiation exposure during cardiac catheterization: Insights from the RadiCure (RADIation reduction during cardiac catheterization using real-timE monitoring) trial.

Authors:  Georgios Christopoulos; Aristotelis C Papayannis; Mohammed Alomar; Georgios E Christakopoulos; Anna Kotsia; Tesfaldet T Michael; Bavana V Rangan; Michele Roesle; Deborah Shorrock; Lorenza Makke; Spyros Maragkoudakis; Atif Mohammad; Karan Sarode; Charles E Chambers; Subhash Banerjee; Emmanouil S Brilakis
Journal:  Catheter Cardiovasc Interv       Date:  2015-12-28       Impact factor: 2.692

10.  The radiation issue in cardiology: the time for action is now.

Authors:  Eugenio Picano; Eliseo Vano
Journal:  Cardiovasc Ultrasound       Date:  2011-11-21       Impact factor: 2.062

View more
  2 in total

1.  Reduction of radiation exposure using low pulse rate fluoroscopy during neuroendovascular surgery.

Authors:  Takeshi Shimizu; Shingo Toyota; Kanji Nakagawa; Tomoaki Murakami; Tetsuya Kumagai; Kanji Mori; Takuyu Taki
Journal:  Interv Neuroradiol       Date:  2020-08-09       Impact factor: 1.610

Review 2.  Radiation protection for the interventional cardiologist: Practical approach and innovations.

Authors:  Alejandro Gutierrez-Barrios; Dolores Cañadas-Pruaño; Inmaculada Noval-Morillas; Livia Gheorghe; Ricardo Zayas-Rueda; German Calle-Perez
Journal:  World J Cardiol       Date:  2022-01-26
  2 in total