| Literature DB >> 31703706 |
D F Cai1, Q H Fan2, H H Zhong2, S Peng2, H Song2.
Abstract
BACKGROUND: The tourniquet is a common medical instrument used in total knee arthroplasty (TKA). However, there has always been a debate about the use of a tourniquet and there is no published meta-analysis to study the effects of a tourniquet on blood loss in primary TKA for patients with osteoarthritis.Entities:
Keywords: Blood loss; Complications; Total knee arthroplasty; Tourniquet
Mesh:
Year: 2019 PMID: 31703706 PMCID: PMC6839231 DOI: 10.1186/s13018-019-1422-4
Source DB: PubMed Journal: J Orthop Surg Res ISSN: 1749-799X Impact factor: 2.359
Fig. 1Flowchart showing the selection process of randomized controlled trials
Characteristics of the included articles
| Study | Year | Sample size | Sex (M/F) | Mean age (years) | BMI (kg/m2) | Cemented | Prosthesis type | Patellar resurfacing | Thromboprophylaxis | Hemostasis | ||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| T | NT | T | NT | T | NT | T | NT | |||||||
| P. Aglietti | 1999 | 10 | 10 | 3/7 | 4/6 | 70.0 | 68.0 | 27.9 | 27.3 | Y | M.B.K, Zimmer | NS | NS | NS |
| H.M. Wakankar | 1999 | 37 | 40 | 11/26 | 14/26 | 72.5 | 71.8 | NS | NS | Y | Insall-Burstein | Y | Warfarin | NS |
| Eric Vanden | 2002 | 40 | 40 | 9/31 | 16/24 | 72.5 | 68.5 | NS | NS | Y | Wallaby I, Protek | NS | NS | NS |
| G. Matziolis | 2005 | 10 | 10 | 2/8 | 3/7 | 72.4 | 76.6 | 28.3 | 29.5 | Y | PFC Sigma, Depuy | N | NS | NS |
| K. Kageyama | 2007 | 11 | 11 | 2/9 | 2/9 | 73.0 | 76.0 | 26.6 | 24.7 | NS | NS | NS | NS | NS |
| Ta-Wei Tai | 2012 | 36 | 36 | 9/27 | 8/28 | 72.1 | 71.5 | 28.6 | 27.9 | Y | Genesis II or U2 | NS | NS | NS |
| Hakan Ledin | 2012 | 25 | 23 | 10/15 | 9/14 | 70.0 | 71.0 | 29.0 | 28.0 | Y | NexgenCR, Zimmer | NS | Low-molecular-weight | NS |
| David Liu | 2014 | 10 | 10 | 7/3 | 9/1 | 67.0 | 70.0 | 25.6 | 27.1 | Y | NS | Y | NS | NS |
| Ashir Ejaz | 2014 | 33 | 31 | 18/15 | 17/14 | 68.0 | 68.0 | 25.0 | 25.0 | Y | NexgenCR, Zimmer | Y | Rivaroxaban | Tranexamic |
| Ashir Ejaz | 2015 | 31 | 31 | 16/15 | 17/14 | 68.3 | 68.2 | 25.1 | 25.2 | Y | NS | Y | NS | NS |
| A. Douglas | 2016 | 28 | 28 | 16/12 | 16/12 | 62.0 | 62.0 | 29.0 | 29.0 | Y | NS | N | Y | NS |
T tourniquet, NT no tourniquet
Fig. 2Risk of bias summary. Green indicates that the criterion is satisfied. Yellow indicates that it is unclear whether the criterion is satisfied or not. Red indicates that the study did not meet the criterion
Fig. 3Forest plot for intraoperative blood loss
Fig. 4Forest plot for postoperative blood loss
Fig. 5Forest plot for total blood loss
Fig. 6Forest plot for calculated blood loss
Fig. 7Forest plot for transfusion rate
Fig. 8Forest plot for DVT rate
Fig. 9Forest plot for operation time