Literature DB >> 31695161

LVPEI Glaucoma Epidemiology and Molecular Genetic Study: teleophthalmology screening for angle-closure disease in an underserved region.

Nikhil S Choudhari1, Premanand Chandran2, Harsha L Rao2, Ganesh B Jonnadula2,3, Uday K Addepalli2,3, Sirisha Senthil2, Chandra Sekhar Garudadri2.   

Abstract

OBJECTIVES: To assess the ability of teleophthalmoscopic grading of peripheral anterior chamber depth (PACD) using the van Herick (vH) technique in detecting gonioscopically occludable angle; and to determine whether combining results from vH grading and ocular biometry can improve the accuracy to diagnose gonioscopically occludable angle
METHODS: This cross-sectional study was an offshoot of a rural population-based study, Glaucoma Epidemiology and Molecular Genetic Study (GLEAMS). A masked urban ophthalmologist graded digital slit lamp photographs of PACD by vH technique. Sussman four-mirror lens was used to perform dark room indentation gonioscopy. Cutoff values of the tests were, vH technique: grade ≤ 2, central anterior chamber depth (ACD), as well as axial length: ≤ 25th percentile and lens thickness ≥ 75th percentile value of the study population.
RESULTS: We studied 1965 eyes of 1029 adult participants. The vH grade was ≤2 in 188 (9.5%) eyes. The angle was occludable by gonioscopy in 101 (5.1%) eyes. The performance of the vH test to rule out gonioscopically occludable angle was good [negative predictive value (NPV): 97.3%], despite low sensitivity (52.5%), while its efficacy to rule in the condition was low [positive predictive value (PPV): 28.2%] despite high specificity (92.8%). However, test combination strategy increased the PPV nearly twofold (53.8%). The calculated PPV at 10% prevalence of gonioscopically occludable angle was even higher (70.5%).
CONCLUSIONS: Van Herick technique can be incorporated into a teleophthalmology program by means of slit lamp photographs of PACD. Combined vH grading and ocular biometry improved the predictability of a gonioscopically occludable angle.

Entities:  

Mesh:

Year:  2019        PMID: 31695161      PMCID: PMC7376055          DOI: 10.1038/s41433-019-0666-x

Source DB:  PubMed          Journal:  Eye (Lond)        ISSN: 0950-222X            Impact factor:   3.775


  3 in total

1.  Validation of visual acuity applications for teleophthalmology during COVID-19.

Authors:  PremNandhini Satgunam; Monika Thakur; Virender Sachdeva; Sneha Reddy; Padmaja Kumari Rani
Journal:  Indian J Ophthalmol       Date:  2021-02       Impact factor: 1.848

2.  Impact of Implementing Teleophthalmology Referral Guidelines Using the eyeSmart EMR App in 63,703 Patients from India.

Authors:  Anthony Vipin Das; Rohit C Khanna; Niranjan Kumar; Padmaja Kumari Rani
Journal:  Int J Telemed Appl       Date:  2022-01-27

3.  Challenges in managing glaucoma-related morbidity due to lockdown in a developing country.

Authors:  Saswati Sen; Matuli Das; Manmath Kumar Das; Snehalata Dash
Journal:  J Family Med Prim Care       Date:  2022-03-18
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.