Literature DB >> 31693247

Continuous-flow mechanical circulatory support is not associated with early graft failure: An analysis of the International Society for Heart and Lung Transplantation registry.

Kevin J Clerkin1, Donna M Mancini2, Josef Stehlik3, Wida S Cherikh4, Lars H Lund5.   

Abstract

BACKGROUND: Continuous-flow mechanical circulatory support (CF-MCS) is associated with impaired vascular function and increased risk of vasoplegia. One contributing factor to early graft failure (EGF) is severe vasoplegia. We tested the hypothesis that CF-MCS is associated with increased risk of EGF.
METHODS: Adult primary heart transplant recipients in the ISHLT Registry from 2005 to 2013 were stratified into three groups based on pre-transplant MCS: No MCS (n = 11 748), pulsatile (P)-MCS (n = 718), and CF-MCS (n = 3818). EGF was defined as death/retransplantation due to graft failure within 30 days after HT. Comparisons were made using descriptive statistics and associations. EGF was assessed with multivariable Cox proportional hazard regression.
RESULTS: The incidence of EGF within 30 days was similar between groups (No MCS 2.2%, P-MCS 3.3%, CF-MCS 2.1%, P = .10). Following multivariable adjustment, the risk of EGF was not statistically different for those with CF-MCS compared with P-MCS (HR 0.75, 95% CI 0.46-1.21, P = .24). The risk of EGF was numerically, but not statistically significantly higher for CF-MCS compared with No MCS (HR 1.24, 95% CI 0.92-1.67, P = .16).
CONCLUSION: CF-MCS use was not associated with a statistically significant increased risk of EGF resulting in death or retransplantation in the first 30 days after transplant.
© 2019 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  early graft failure; heart transplantation; mechanical circulatory support

Mesh:

Year:  2019        PMID: 31693247      PMCID: PMC6933077          DOI: 10.1111/ctr.13752

Source DB:  PubMed          Journal:  Clin Transplant        ISSN: 0902-0063            Impact factor:   2.863


  25 in total

1.  Improved outcomes from extracorporeal membrane oxygenation versus ventricular assist device temporary support of primary graft dysfunction in heart transplant.

Authors:  Koji Takeda; Boyangzi Li; Arthur R Garan; Veli K Topkara; Jiho Han; Paolo C Colombo; Maryjane A Farr; Yoshifumi Naka; Hiroo Takayama
Journal:  J Heart Lung Transplant       Date:  2016-12-23       Impact factor: 10.247

2.  Incidence and outcome of Levitronix CentriMag support as rescue therapy for early cardiac allograft failure: a United Kingdom national study.

Authors:  Helen L Thomas; Vamsidhar B Dronavalli; Jayan Parameshwar; Robert S Bonser; Nicholas R Banner
Journal:  Eur J Cardiothorac Surg       Date:  2011-04-14       Impact factor: 4.191

Review 3.  The Registry of the International Society for Heart and Lung Transplantation: Thirty-third Adult Heart Transplantation Report-2016; Focus Theme: Primary Diagnostic Indications for Transplant.

Authors:  Lars H Lund; Leah B Edwards; Anne I Dipchand; Samuel Goldfarb; Anna Y Kucheryavaya; Bronwyn J Levvey; Bruno Meiser; Joseph W Rossano; Roger D Yusen; Josef Stehlik
Journal:  J Heart Lung Transplant       Date:  2016-08-21       Impact factor: 10.247

4.  Peripheral vascular reactivity in patients with pulsatile vs axial flow left ventricular assist device support.

Authors:  Offer Amir; Branislav Radovancevic; Reynolds M Delgado; Biswajit Kar; Rajko Radovancevic; Maria Henderson; William E Cohn; Frank W Smart
Journal:  J Heart Lung Transplant       Date:  2006-02-03       Impact factor: 10.247

5.  Morphologic changes of the aortic wall due to reduced systemic pulse pressure in prolonged non pulsatile left heart bypass.

Authors:  T Nishimura; E Tatsumi; S Takaichi; Y Taenaka; Y Wakisaka; T Nakatani; T Masuzawa; Y Takewa; M Nakamura; S Endo; Y S Sohn; H Takano
Journal:  ASAIO J       Date:  1997 Sep-Oct       Impact factor: 2.872

6.  Macrovascular and microvascular function after implantation of left ventricular assist devices in end-stage heart failure: Role of microparticles.

Authors:  Roberto Sansone; Beate Stanske; Stefanie Keymel; Dominik Schuler; Patrick Horn; Diyar Saeed; Udo Boeken; Ralf Westenfeld; Artur Lichtenberg; Malte Kelm; Christian Heiss
Journal:  J Heart Lung Transplant       Date:  2015-03-24       Impact factor: 10.247

7.  RADIAL: a novel primary graft failure risk score in heart transplantation.

Authors:  Javier Segovia; M Dolores G Cosío; Juan M Barceló; Manuel Gómez Bueno; Pablo García Pavía; Raúl Burgos; Santiago Serrano-Fiz; Carlos García-Montero; Evaristo Castedo; Juan Ugarte; Luis Alonso-Pulpón
Journal:  J Heart Lung Transplant       Date:  2011-04-05       Impact factor: 10.247

8.  Amiodarone use in patients listed for heart transplant is associated with increased 1-year post-transplant mortality.

Authors:  Lauren B Cooper; Robert J Mentz; Leah B Edwards; Amber R Wilk; Joseph G Rogers; Chetan B Patel; Carmelo A Milano; Adrian F Hernandez; Josef Stehlik; Lars H Lund
Journal:  J Heart Lung Transplant       Date:  2016-07-17       Impact factor: 10.247

9.  Sympathetic neural and hemodynamic responses to upright tilt in patients with pulsatile and nonpulsatile left ventricular assist devices.

Authors:  David W Markham; Qi Fu; M Dean Palmer; Mark H Drazner; Dan M Meyer; Brian T Bethea; Jeffrey L Hastings; Naoki Fujimoto; Shigeki Shibata; Benjamin D Levine
Journal:  Circ Heart Fail       Date:  2012-12-18       Impact factor: 8.790

Review 10.  Comparison of Propensity Score Methods and Covariate Adjustment: Evaluation in 4 Cardiovascular Studies.

Authors:  Markus C Elze; John Gregson; Usman Baber; Elizabeth Williamson; Samantha Sartori; Roxana Mehran; Melissa Nichols; Gregg W Stone; Stuart J Pocock
Journal:  J Am Coll Cardiol       Date:  2017-01-24       Impact factor: 24.094

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.