Literature DB >> 31691053

Effect of ozone and diode laser (635 nm) in reducing orthodontic pain in the maxillary arch-a randomized clinical controlled trial.

Jacek Matys1,2, Elżbieta Jaszczak3, Rafał Flieger4, Katarzyna Kostrzewska-Kaminiarz3, Kinga Grzech-Leśniak5, Marzena Dominiak5.   

Abstract

The effect of ozone, diode laser irradiation, and presence of teeth crowding/spacing on pain perception in orthodontic patient was tested. Overall, 76 patients [55 women and 21 men; age 35.1(6.4) years] who met the inclusion criteria participated in the study. Immediately after fixed orthodontic appliance placement, the patients were exposed to a pain relief treatment (one single session) using either 635-nm diode laser (SmartM, Lasotronix, Warsaw, Poland) or ozone therapy (OzoneDTA, Apoza, New Taipei City, Taiwan) by placing the handpieces in the area of each teeth apex and interdental papillae, from the maxillary right first molar to the maxillary left first molar. Subjects were divided into three groups: control group (G1, n = 26), ozone (G2, n = 26, exposed to ozone therapy, generator probe type 3, working time per point 5 s, 23 points, application time 1 min and 55 s), and laser group (G3, n = 25, exposed to continuous mode diode laser, 400 mW, handpiece diameter 8 mm, spot area 0.5024 cm2, power density per second 1.59 W/cm2, dose 2 J per point, time: 5 s per point, 23 points, total energy per session 46 J, application time 1 min and 55 s). The level of teeth crowding was assessed using the Lundstrom indicator. The patients received a questionnaire for pain assessment (the Numeric Rating Scale, NRS-11, grade level 0-10) and recorded at 7 time points (1 h, 6 h, and 1, 2, 3, 4, and 5 days ) after the fixed orthodontic appliance placement. The mean pain values for the diode laser, ozone, and control group were 3.6 (1.31) (95% CI, 2.95-4.25), 5.25 (3.37) (95% CI, 3.52-6.98), and 5.75 (2.40) (95% CI, 4.69-6.81), respectively. We observed lower pain values in the diode laser group compared to the control group (p = 0.0237). The use of ozone in this study did not result in significant pain reduction in comparison to control (p = 0.8040) and laser groups (p = 0.1029). There were no differences in pain perception between patients with crowded teeth and non-crowded teeth in each group (G1, p = 0.66, G2, p = 0.86, G3, p = 0.24). The use of 635-nm diode laser led to decreased pain perception; however, ozone and presence of teeth crowding/spacing did not affect the pain perception in orthodontic patients during the first 5 days after the fixed orthodontic appliance placement.

Entities:  

Keywords:  Biostimulation; Crowding; Fixed appliance; Photobiomodulation; Teeth

Mesh:

Substances:

Year:  2019        PMID: 31691053     DOI: 10.1007/s10103-019-02896-0

Source DB:  PubMed          Journal:  Lasers Med Sci        ISSN: 0268-8921            Impact factor:   3.161


  37 in total

1.  Pain reduction after initial archwire placement in orthodontic patients: a randomized clinical trial.

Authors:  Fahimeh Farzanegan; Seyed Mojtaba Zebarjad; Sanaz Alizadeh; Farzaneh Ahrari
Journal:  Am J Orthod Dentofacial Orthop       Date:  2012-02       Impact factor: 2.650

2.  Er:YAG Laser for Metal and Ceramic Bracket Debonding: An In Vitro Study on Intrapulpal Temperature, SEM, and EDS Analysis.

Authors:  Kinga Grzech-Leśniak; Jacek Matys; Dorota Żmuda-Stawowiak; Krzysztof Mroczka; Marzena Dominiak; Aldo Brugnera Junior; Reinhard Gruber; Georgios E Romanos; Anton Sculean
Journal:  Photomed Laser Surg       Date:  2018-06-15       Impact factor: 2.796

3.  The effect of 810-nm low-level laser therapy on pain caused by orthodontic elastomeric separators.

Authors:  Ladan Eslamian; Ali Borzabadi-Farahani; Aidin Hassanzadeh-Azhiri; Mohammad R Badiee; Reza Fekrazad
Journal:  Lasers Med Sci       Date:  2013-01-20       Impact factor: 3.161

Review 4.  Low-level laser therapy for orthodontic pain: a systematic review.

Authors:  F J Li; J Y Zhang; X T Zeng; Y Guo
Journal:  Lasers Med Sci       Date:  2014-09-26       Impact factor: 3.161

5.  Evaluating low-level laser therapy effect on reducing orthodontic pain using two laser energy values: a split-mouth randomized placebo-controlled trial.

Authors:  Mohammad Moaffak A AlSayed Hasan; Kinda Sultan; Omar Hamadah
Journal:  Eur J Orthod       Date:  2018-01-23       Impact factor: 3.075

6.  Evaluation of the use of low-level laser therapy in pain control in orthodontic patients: A randomized split-mouth clinical trial.

Authors:  Rodrigo Duarte Farias; Luciane Quadrado Closs; Sergio Augusto Quevedo Miguens
Journal:  Angle Orthod       Date:  2015-07-01       Impact factor: 2.079

7.  The effect of benzocaine and ketoprofen gels on pain during fixed orthodontic appliance treatment: a randomised, double-blind, crossover trial.

Authors:  Ladan Eslamian; Ali Borzabadi-Farahani; Hadi Gholami
Journal:  Aust Orthod J       Date:  2016-05

8.  Time course of the discomfort in young patients undergoing orthodontic treatment.

Authors:  S Wilson; P Ngan; B Kess
Journal:  Pediatr Dent       Date:  1989-06       Impact factor: 1.874

9.  Effects of single-dose, low-level laser therapy on pain associated with the initial stage of fixed orthodontic treatment: A randomized clinical trial.

Authors:  Irfan Qamruddin; Mohammad Khursheed Alam; Habiba Abdullah; Muhammad Abdullah Kamran; Nausheen Jawaid; Verda Mahroof
Journal:  Korean J Orthod       Date:  2018-02-06       Impact factor: 1.372

10.  Effect of frequent laser irradiation on orthodontic pain. A single-blind randomized clinical trial.

Authors:  Won Tae Kim; Mohamed Bayome; Jun-Beom Park; Jae Hyun Park; Seung-Hak Baek; Yoon-Ah Kook
Journal:  Angle Orthod       Date:  2012-12-14       Impact factor: 2.079

View more
  8 in total

1.  Effects of high-frequency near infrared laser irradiation on experimental tooth movement-induced pain in rats.

Authors:  Ayaka Nakatani; Ryo Kunimatsu; Yuji Tsuka; Shuzo Sakata; Kayo Horie; Hidemi Gunji; Shota Ito; Isamu Kado; Nurul Aisyah Rizky Putranti; Ryuji Terayama; Kotaro Tanimoto
Journal:  Lasers Med Sci       Date:  2022-06-13       Impact factor: 2.555

2.  Effect of low-level laser therapy on the time needed for leveling and alignment of mandibular anterior crowding.

Authors:  Yasmine Khaled Abdel Ghaffar; Fouad A El Sharaby; Ibrahim Mazen Negm
Journal:  Angle Orthod       Date:  2022-07-01       Impact factor: 2.684

3.  Effect of 808 nm Semiconductor Laser on the Stability of Orthodontic Micro-Implants: A Split-Mouth Study.

Authors:  Jacek Matys; Rafał Flieger; Tomasz Gedrange; Krzysztof Janowicz; Bartosz Kempisty; Kinga Grzech-Leśniak; Marzena Dominiak
Journal:  Materials (Basel)       Date:  2020-05-14       Impact factor: 3.623

4.  Effectiveness of low-level laser therapy and chewing gum in reducing orthodontic pain: A randomized controlled trial.

Authors:  Fatih Celebi; Ali Altug Bicakci; Ufuk Kelesoglu
Journal:  Korean J Orthod       Date:  2021-09-25       Impact factor: 1.372

5.  Pain Perception Associated with Mini-Implants and Interventions for Pain Management: A Cross-Sectional Questionnaire-Based Survey.

Authors:  Swapna Sreenivasagan; Aravind Kumar Subramanian; Abirami Selvaraj; Anand Marya
Journal:  Biomed Res Int       Date:  2021-11-29       Impact factor: 3.411

Review 6.  The Protocol of Low-level Laser Therapy in Orthodontic Practice: A Scoping Review of Literature.

Authors:  Rochaya Chintavalakorn; Nuntinee Nanthavanich Saengfai; Kawin Sipiyaruk
Journal:  J Int Soc Prev Community Dent       Date:  2022-04-13

7.  Nonpharmacological Interventions for Pain in Patients with Temporomandibular Joint Disorders: A Systematic Review.

Authors:  Liliana Argueta-Figueroa; Luis Angel Flores-Mejía; Beatriz Xóchitl Ávila-Curiel; Blanca Irma Flores-Ferreyra; Rafael Torres-Rosas
Journal:  Eur J Dent       Date:  2022-03-08

8.  Low-Level Laser Therapy with a 635 nm Diode Laser Affects Orthodontic Mini-Implants Stability: A Randomized Clinical Split-Mouth Trial.

Authors:  Rafał Flieger; Tomasz Gedrange; Kinga Grzech-Leśniak; Marzena Dominiak; Jacek Matys
Journal:  J Clin Med       Date:  2019-12-31       Impact factor: 4.241

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.