Literature DB >> 3168218

Estradiol-17 beta quantified in serum by isotope dilution-gas chromatography-mass spectrometry: reversed-phase C18 high-performance liquid chromatography compared with immuno-affinity chromatography for sample pretreatment.

L M Thienpont1, P G Verhaeghe, K A Van Brussel, A P De Leenheer.   

Abstract

Here, isotope dilution-gas chromatography-mass spectometry is used as a reference technique for determining the concentration of estradiol-17 beta in candidate human serum Reference Material. The accuracy of assigned concentrations in biologic materials is not only determined by instrumental performance, it also depends greatly on the selectivity of the procedure for isolating the analyte from the biological matrix, an issue which we consider insufficiently addressed in the literature. We introduced reversed-phase C18 high-performance liquid chromatography as a fractionation procedure in addition to the commonly used solvent extraction and column chromatography on Sephadex LH-20. The validity of this approach as part of a Reference Method for measurement of estradiol-17 beta by isotope dilution-gas chromatography-mass spectrometry was investigated by comparison with immuno-affinity chromatography, which on theoretical grounds is generally considered as highly selective.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3168218

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  4 in total

1.  High variability in serum estradiol measurements in men and women.

Authors:  Hubert W Vesper; Julianne C Botelho; Meghan L Vidal; Yasamin Rahmani; Linda M Thienpont; Samuel P Caudill
Journal:  Steroids       Date:  2014-01-06       Impact factor: 2.668

Review 2.  Challenges to the measurement of estradiol: an endocrine society position statement.

Authors:  William Rosner; Susan E Hankinson; Patrick M Sluss; Hubert W Vesper; Margaret E Wierman
Journal:  J Clin Endocrinol Metab       Date:  2013-03-05       Impact factor: 5.958

3.  A Sensitive and Specific ESI-Positive LC-MS/MS Method for the Quantitation of Estrogens in Human Serum in Under Three Minutes.

Authors:  Aaron Stella; Subhakar Dey
Journal:  J Chromatogr Sci       Date:  2021-02-15       Impact factor: 1.618

4.  EStradiol and PRogesterone in In vitro ferTilization (ESPRIT): a multicenter study evaluating third- versus second-generation estradiol and progesterone immunoassays.

Authors:  N P Polyzos; E Anckaert; P Drakopoulos; H Tournaye; J Schiettecatte; H Donner; G Bobba; G Miles; W D J Verhagen-Kamerbeek; E Bosch
Journal:  J Endocrinol Invest       Date:  2020-03-13       Impact factor: 4.256

  4 in total