Literature DB >> 3168192

Transesophageal two-dimensional echocardiography and color Doppler flow velocity mapping in the evaluation of cardiac valve prostheses.

U Nellessen1, I Schnittger, C P Appleton, T Masuyama, A Bolger, T A Fischell, T Tye, R L Popp.   

Abstract

To determine the value of transesophageal ultrasound in the assessment of cardiac valve prostheses, 14 patients with clinically suspected mitral prosthesis malfunction were studied by transthoracic and transesophageal two-dimensional imaging as well as by color Doppler flow velocity mapping (color Doppler). Patients underwent left ventricular angiography (n = 13), surgery (n = 11), or both angiography and surgery (n = 10). Nine patients had only mitral valve replacement, four patients had both mitral and aortic valve replacement, and one patient had mitral, aortic, and tricuspid valve replacement. There were 16 biological and four mechanical prostheses. The degree of mitral regurgitation was graded by both transthoracic and transesophageal color Doppler according to the area of the regurgitant jet visualized and was compared with a three-point classification of mitral regurgitation by left ventricular angiography judged by observers blinded to the echocardiographic results. All transesophageal studies were performed without complication and were well tolerated. The pathological morphology of the mitral prosthesis was additionally or more clearly visualized by transesophageal two-dimensional imaging and subsequently proven at surgery in three patients with flail leaflets and one patient with a vegetation compared with images obtained by the transthoracic approach. Valvular regurgitation was graded by the transthoracic approach as absent in four patients, mild in two patients, moderate in five patients, and severe in only three patients. The transesophageal assessment showed absence of mitral regurgitation in two patients, moderate regurgitation in two patients, and severe regurgitation in 10 patients.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1988        PMID: 3168192     DOI: 10.1161/01.cir.78.4.848

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  6 in total

1.  Update on echocardiography in the management of infective endocarditis.

Authors:  John Francis Sedgwick; Darryl John Burstow
Journal:  Curr Infect Dis Rep       Date:  2012-08       Impact factor: 3.725

2.  Detection of acute thrombosis of mitral tilting disk prosthesis by transesophageal echocardiography.

Authors:  P Ius; A Giacomin; A Cavarzerani; C Valfré
Journal:  Int J Card Imaging       Date:  1994-12

3.  Echocardiographic assessment of artificial heart valves: British Society of Echocardiography position paper.

Authors:  J Chambers; A Fraser; P Lawford; P Nihoyannopoulos; I Simpson
Journal:  Br Heart J       Date:  1994-04

4.  Assessment of severity of mechanical prosthetic mitral regurgitation by transoesophageal echocardiography.

Authors:  A Vitarelli; Y Conde; E Cimino; T Leone; I D'Angeli; S D'Orazio; S Stellato
Journal:  Heart       Date:  2004-05       Impact factor: 5.994

5.  Role of transoesophageal echocardiography in the diagnosis and management of aortic root abscess.

Authors:  D Y Leung; G B Cranney; A P Hopkins; W F Walsh
Journal:  Br Heart J       Date:  1994-08

6.  Novel imaging strategies for the detection of prosthetic heart valve obstruction and endocarditis.

Authors:  W Tanis; R P J Budde; I A C van der Bilt; B Delemarre; G Hoohenkerk; J-K van Rooden; A M Scholtens; J Habets; S Chamuleau
Journal:  Neth Heart J       Date:  2016-02       Impact factor: 2.380

  6 in total