Literature DB >> 31667026

Sex-Related Differences in Photoplethysmography Signals Measured From Finger and Toe.

Seyedmohsen Dehghanojamahalleh1, Mehmet Kaya1.   

Abstract

Sex plays an important role in the normal cardiovascular system function including resting heart rate and arterial blood pressure. In addition, it has been reported that men and women are at different levels of risk for cardiovascular diseases. The aim of this study was to evaluate and compare the temporal and morphological features of both finger and toe photoplethysmography (PPG), and anthropometric and biological parameters with respect to sex. A customized PPG and electrocardiography (ECG) combo device was developed to measure the signals of interest. ECG/PPG features in addition to subjects' information were compared regarding finger and toe PPGs. Eighty-eight subjects participated in the study. Linear regression and Student's t-test were used for statistical analysis. Our results revealed that pulse arrival time (PAT), pulse transit time (PTT), systolic pulse transit time (SPTT), and the ratio of areas under the PPG waveform from the onset to the inflection point and the inflection point to the end of the waveform (S2/S1), are dependent on sex. The highest dependence was shown for the finger PTT while the toe PTT did not indicate any significant dependence on sex. This is the first study that evaluates the effect of sex on cardiovascular system function using finger and toe PPG based features which can help to understand sex-based risk factors for cardiovascular diseases and to improve related disease management and treatments. This work is licensed under a Creative Commons Attribution 4.0 License. For more information, see http://creativecommons.org/licenses/by/4.0/.

Entities:  

Keywords:  PPG; PTT; Sex; Toe; finger

Year:  2019        PMID: 31667026      PMCID: PMC6752633          DOI: 10.1109/JTEHM.2019.2938506

Source DB:  PubMed          Journal:  IEEE J Transl Eng Health Med        ISSN: 2168-2372            Impact factor:   3.316


  25 in total

Review 1.  Relation between heart rate and pulse transit time during paced respiration.

Authors:  M J Drinnan; J Allen; A Murray
Journal:  Physiol Meas       Date:  2001-08       Impact factor: 2.833

2.  Pulse wave transit time for monitoring respiration rate.

Authors:  A Johansson; C Ahlstrom; T Lanne; P Ask
Journal:  Med Biol Eng Comput       Date:  2006-05-31       Impact factor: 2.602

3.  Blood flow measurements at different depths using photoplethysmography and laser Doppler techniques.

Authors:  Sara Bergstrand; Lars Göran Lindberg; Anna-Christina Ek; Maria Lindén; Margareta Lindgren
Journal:  Skin Res Technol       Date:  2009-05       Impact factor: 2.365

4.  Comparison of pulse wave velocity derived from accelerometer and reflective photo-plethysmography signals placed at the carotid and femoral artery.

Authors:  Jens Muehlsteff; Erik Bresch; Lars Schmitt; Jos Gelissen; Peter Bingley
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2016-08

5.  Photoplethysmography detection of lower limb peripheral arterial occlusive disease: a comparison of pulse timing, amplitude and shape characteristics.

Authors:  John Allen; Crispian P Oates; Timothy A Lees; Alan Murray
Journal:  Physiol Meas       Date:  2005-07-06       Impact factor: 2.833

6.  Sex differences in vascular dysfunction and cardiovascular outcomes: The cardiac, endothelial function, and arterial stiffness in ESRD (CERES) study.

Authors:  Isabella Guajardo; Amrita Ayer; Alexander D Johnson; Peter Ganz; Claire Mills; Catherine Donovan; Rebecca Scherzer; Sanjiv J Shah; Carmen A Peralta; Ruth F Dubin
Journal:  Hemodial Int       Date:  2017-03-08       Impact factor: 1.812

7.  Continuous blood pressure measurement by using the pulse transit time: comparison to a cuff-based method.

Authors:  Heiko Gesche; Detlef Grosskurth; Gert Küchler; Andreas Patzak
Journal:  Eur J Appl Physiol       Date:  2011-05-10       Impact factor: 3.078

8.  Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice.

Authors:  Ramakrishna Mukkamala; Jin-Oh Hahn; Omer T Inan; Lalit K Mestha; Chang-Sei Kim; Hakan Töreyin; Survi Kyal
Journal:  IEEE Trans Biomed Eng       Date:  2015-06-05       Impact factor: 4.538

9.  Age-related changes in the characteristics of the photoplethysmographic pulse shape at various body sites.

Authors:  John Allen; Alan Murray
Journal:  Physiol Meas       Date:  2003-05       Impact factor: 2.833

10.  Changes in arterial stiffness and wave reflection with advancing age in healthy men and women: the Framingham Heart Study.

Authors:  Gary F Mitchell; Helen Parise; Emelia J Benjamin; Martin G Larson; Michelle J Keyes; Joseph A Vita; Ramachandran S Vasan; Daniel Levy
Journal:  Hypertension       Date:  2004-05-03       Impact factor: 10.190

View more
  2 in total

1.  Recommendations for determining the validity of consumer wearable heart rate devices: expert statement and checklist of the INTERLIVE Network.

Authors:  Jan M Mühlen; Julie Stang; Esben Lykke Skovgaard; Pedro B Judice; Pablo Molina-Garcia; William Johnston; Luís B Sardinha; Francisco B Ortega; Brian Caulfield; Wilhelm Bloch; Sulin Cheng; Ulf Ekelund; Jan Christian Brønd; Anders Grøntved; Moritz Schumann
Journal:  Br J Sports Med       Date:  2021-01-04       Impact factor: 13.800

2.  Quality Assessment and Morphological Analysis of Photoplethysmography in Daily Life.

Authors:  Serena Moscato; Luca Palmerini; Pierpaolo Palumbo; Lorenzo Chiari
Journal:  Front Digit Health       Date:  2022-07-07
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.