Literature DB >> 12812416

Age-related changes in the characteristics of the photoplethysmographic pulse shape at various body sites.

John Allen1, Alan Murray.   

Abstract

It is accepted that older subjects have increasing arterial stiffness resulting in changes in the propagation of the pulse to the periphery, and thereby influencing the peripheral pulse timing and shape characteristics. However, this age association with pulse shape is less clear in younger subjects and for different peripheral measurement sites. The aim of this study was to determine the association between age and changes in pulse shape characteristics at the ears, fingers and toes. Photoplethysmography pulse waveforms were recorded non-invasively from the right and left sides at the ears, index fingers and great toes of 116 normal healthy human subjects. Their median age was 41 years (range 13-72) allowing four distinct age groups to be considered (subjects younger than 30 years, 30-39 years, 40-49 years and 50 years of age or older). Normalized ear, finger and toe pulse shapes were calculated, for the whole subject group, and for the subjects within each age group. The differences in shape, relative to the oldest group, were also calculated for two distinct regions of interest: the systolic rising edge and the dicrotic notch of the pulse. Subtle, gradual and significant changes in the pulse shape were found at all sites with overall elongation of the systolic rising edge (p < 0.05) and damping of the dicrotic notch (p < 0.05) with age. The overall age-related changes in multi-site PPG pulse shape characteristics at the ear, finger and toe sites have been demonstrated and quantified. Age-matched normal ranges must be considered when evaluating pulses from patients with possible vascular disease.

Entities:  

Mesh:

Year:  2003        PMID: 12812416     DOI: 10.1088/0967-3334/24/2/306

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  29 in total

1.  Monitoring of cardiovascular reactivity to cold stress using digital volume pulse characteristics in health and diabetes.

Authors:  Ashok K Jaryal; Nandakumar Selvaraj; Jayashree Santhosh; Sneh Anand; Kishore K Deepak
Journal:  J Clin Monit Comput       Date:  2009-03-24       Impact factor: 2.502

2.  Tracking cerebral blood flow in BOLD fMRI using recursively generated regressors.

Authors:  Yunjie Tong; Blaise deB Frederick
Journal:  Hum Brain Mapp       Date:  2014-06-23       Impact factor: 5.038

3.  Wearable speckle plethysmography (SPG) for characterizing microvascular flow and resistance.

Authors:  Michael Ghijsen; Tyler B Rice; Bruce Yang; Sean M White; Bruce J Tromberg
Journal:  Biomed Opt Express       Date:  2018-07-30       Impact factor: 3.732

4.  Assessment of Subtle Changes in Diabetes-Associated Arteriosclerosis using Photoplethysmographic Pulse Wave from Index Finger.

Authors:  Po-Chun Hsu; Hsien-Tsai Wu; Cheuk-Kwan Sun
Journal:  J Med Syst       Date:  2018-01-24       Impact factor: 4.460

Review 5.  Photoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging.

Authors:  Yu Sun; Nitish Thakor
Journal:  IEEE Trans Biomed Eng       Date:  2015-09-15       Impact factor: 4.538

6.  Photoplethysmographic characterization of vascular tone mediated changes in arterial pressure: an observational study.

Authors:  Gerardo Tusman; Cecilia M Acosta; Sven Pulletz; Stephan H Böhm; Adriana Scandurra; Jorge Martinez Arca; Matías Madorno; Fernando Suarez Sipmann
Journal:  J Clin Monit Comput       Date:  2018-12-15       Impact factor: 2.502

7.  Adaptive network-based fuzzy inference system for assessment of lower limb peripheral vascular occlusive disease.

Authors:  Yi-Chun Du; Chia-Hung Lin
Journal:  J Med Syst       Date:  2010-04-13       Impact factor: 4.460

8.  Comparison of blood volume pulse and skin conductance responses to mental and affective stimuli at different anatomical sites.

Authors:  Azadeh Kushki; Jillian Fairley; Satyam Merja; Gillian King; Tom Chau
Journal:  Physiol Meas       Date:  2011-08-18       Impact factor: 2.833

9.  Sex-Related Differences in Photoplethysmography Signals Measured From Finger and Toe.

Authors:  Seyedmohsen Dehghanojamahalleh; Mehmet Kaya
Journal:  IEEE J Transl Eng Health Med       Date:  2019-08-30       Impact factor: 3.316

10.  Computerized assessment of communication for cognitive stimulation for people with cognitive decline using spectral-distortion measures and phylogenetic inference.

Authors:  Tuan D Pham; Mayumi Oyama-Higa; Cong-Thang Truong; Kazushi Okamoto; Terufumi Futaba; Shigeru Kanemoto; Masahide Sugiyama; Lisa Lampe
Journal:  PLoS One       Date:  2015-03-24       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.