| Literature DB >> 31666051 |
Cara L Fisher1, Tebyan Rabbani2, Katelyn Johnson2, Rustin Reeves2, Addison Wood2,3.
Abstract
BACKGROUND: Ankle syndesmosis injuries are common and range in severity from subclinical to grossly unstable. Definitive diagnosis of these injuries can be made with plain film radiographs, but are often missed when severity or image quality is low. Computed tomography (CT) and magnetic resonance imaging (MRI) can provide definitive diagnosis, but are costly and introduce the patient to radiation when CT is used. Ultrasonography may circumvent many of these disadvantages by being inexpensive, efficient, and able to detect injuries without radiation exposure. The purpose of this study was to evaluate the ability of ultrasonography to detect early stage supination-external rotation (SER) ankle syndesmosis injuries with a dynamic external rotational stress test.Entities:
Keywords: AITFL; Ankle fracture; Syndesmosis; Ultrasonography
Mesh:
Year: 2019 PMID: 31666051 PMCID: PMC6822462 DOI: 10.1186/s12891-019-2899-z
Source DB: PubMed Journal: BMC Musculoskelet Disord ISSN: 1471-2474 Impact factor: 2.362
Lauge-Hansen SER Stages, where each stage of injury is in addition to the prior
| Stage 1 | AITFL |
| Stage 2 | Fibula Fracture (Fx) |
| Stage 3 | PITFL or Posterior Malleolar Fx |
| Stage 4 | Deltoid or Medial Malleolar Fx |
Fig. 1In vitro simulation ankle rig used for dynamic ultrasonography evaluation
Summary of Bland-Altman analyses of average difference in tibiofibular clear space measurements. AITFL – anterior inferior tibiofibular ligament, PITFL – posterior inferior tibiofibular ligament
| Injury Phase | Observer 1 vs. Observer 2 | Observer 1 vs. Observer 3 | Observer 2 vs. Observer 3 |
| Normal | 3.64 | 2.32 | -1.32 |
| 75 AITFL | 2.47 | 1.90 | -0.40 |
| 100 AITFL | 3.06 | 2.88 | -0.22 |
| Fibula Fracture | 2.96 | 2.79 | -0.17 |
| 75 PITFL | 1.83 | 2.43 | 0.58 |
| 100 PITFL | 1.18 | 1.77 | 0.59 |
| Mean Average (Std. Dev.) | 2.52 (0.89) | 2.35 (0.45) | -0.16 (0.71) |
Fig. 2Tibiofibular clear space measurements at 10 Nm of external rotational torque at each injury level experienced in the experiment. Uninjured injury level (US_Normal); 75% of AITFL cut injury level (US_75A); 100% AITFL cut injury level (US_100A); Fibula fracture 8 cm proximal to plafond injury level (US_Fx); 75% PITFL cut injury level (US_75P); 100% PITFL cut injury level (US_100P)
Fig. 3Ultrasound imaging of the tibiofibular clear space at 10 Nm of external rotational torque. White line indicates tibiofibular clear space. a Intact; (b) 75 AITFL; (c) 100 AITFL; (d) Fibula Fracture; (e) 75 PITFL; (f) 100 PITFL; [T] Tibia; [F] Fibula