Literature DB >> 31655019

Use of the metal artefact reduction tool in the identification of fractured endodontic instruments in cone-beam computed tomography.

E D Costa1, D M Brasil1, P M Queiroz1, F S Verner2, R B Junqueira3, D Q Freitas1.   

Abstract

AIM: To evaluate the influence of the metal artefact reduction (MAR) tool in the diagnosis of fractured instruments in root canals of extracted mandibular molars, with or without root canal fillings.
METHODOLOGY: The root canals of 31 mandibular molars were divided into four groups: (i) the control group, without root fillings; (ii) the fracture group, without fillings and with fractured files; (iii) the fill group, with root filling; and (iv) the fill/fracture group, root filled and with fractured files. The following instruments were used as fractured endodontic instruments: stainless steel hand files, NiTi reciprocating files and NiTi rotary files. Each tooth was inserted in a dry mandible to obtain cone-beam computed tomography (CBCT) images using a CBCT OP300 3D Maxio (Instrumentarium Dental, Tuusula, Finland) and Picasso Trio (Vatech, Hwaseong, Republic of Korea), with and without application of the MAR tool. All images were evaluated by three radiologists for the presence or absence of fractured files on a 5-point scale. The diagnostic accuracy (area under ROC curve) was calculated. Image noise was measured in regions of trabecular and cortical bone and soft tissue. The comparison between the ROC curve values with the MAR tool enabled or disabled was performed using a t-test. A t-test was also employed for comparing image noise when the MAR tool was enabled and disabled. The significance level was set at 5%.
RESULTS: The use of the MAR tool did not influence the diagnostic accuracy for identifying fractured endodontic instruments in root canals with and without fillings in both CBCT systems (P > 0.05), nor did it influence the image noise (P > 0.05).
CONCLUSIONS: The MAR tool on these two devices did not increase the detection of fractured endodontic instruments and did not reduce image noise using extracted mandibular molars. Therefore, the MAR tool is not recommended for evaluation of fractured endodontic instruments in teeth with and without root fillings in mandibular molars.
© 2019 International Endodontic Journal. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  cone-beam computed tomography; endodontics; instrumentation

Year:  2019        PMID: 31655019     DOI: 10.1111/iej.13242

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  5 in total

1.  Do the number of basis images and metal artifact reduction affect the production of artifacts near and far from zirconium dental implants in CBCT?

Authors:  Eduarda Helena Leandro Nascimento; Hugo Gaêta-Araujo; Rocharles Cavalcante Fontenele; Nicolly Oliveira-Santos; Christiano Oliveira-Santos; Deborah Queiroz Freitas
Journal:  Clin Oral Investig       Date:  2021-02-24       Impact factor: 3.573

2.  CBCT image artefacts generated by implants located inside the field of view or in the exomass.

Authors:  Husniye Demirturk Kocasarac; Lisa J Koenig; Gulbahar Ustaoglu; Matheus Lima Oliveira; Deborah Queiroz Freitas
Journal:  Dentomaxillofac Radiol       Date:  2021-07-29       Impact factor: 2.419

3.  Influence of CBCT-based volumetric distortion and beam hardening artefacts on the assessment of root canal filling quality in isthmus-containing molars.

Authors:  Clarissa Teles Rodrigues; Reinhilde Jacobs; Karla Faria Vasconcelos; Paul Lambrechts; Izabel Regina Fisher Rubira-Bullen; Hugo Gaêta-Araujo; Christiano Oliveira-Santos; Marco Antonio Hungaro Duarte
Journal:  Dentomaxillofac Radiol       Date:  2021-01-05       Impact factor: 3.525

4.  The Effect of Cone-Beam Computed Tomography (CBCT) Evaluation on Treatment Planning after Endodontic Instrument Fracture.

Authors:  Konstantinos Kalogeropoulos; Alexandra Xiropotamou; Despina Koletsi; Giorgos N Tzanetakis
Journal:  Int J Environ Res Public Health       Date:  2022-03-30       Impact factor: 3.390

5.  Influence of windowing and metal artefact reduction algorithms on the volumetric dimensions of five different high-density materials: a cone-beam CT study.

Authors:  Fernanda Coelho-Silva; Luciano Augusto Cano Martins; Daniela Azeredo Braga; Eliana Zandonade; Francisco Haiter-Neto; Sergio Lins de-Azevedo-Vaz
Journal:  Dentomaxillofac Radiol       Date:  2020-06-25       Impact factor: 2.419

  5 in total