Literature DB >> 31641798

Diagnosis of Candida albicans: conventional diagnostic methods compared to the loop-mediated isothermal amplification (LAMP) assay.

Shirzad Fallahi1,2, Milad Babaei3, Ali Rostami4, Hadi Mirahmadi5, Zahra Arab-Mazar6, Asghar Sepahvand7,8.   

Abstract

Candida species cause a wide range of opportunistic infections in humans and animals. The detection of Candida species by conventional diagnosis methods is costly and time consuming. This study was conducted for the first time to evaluate and compare a relatively new molecular assay and the loop-mediated isothermal amplification (LAMP) technique with conventional methods for detection of Candida albicans. In this study, 70 different species of Candida identified by conventional methods were cultured on Sabouraud chloramphenicol agar medium and then the genomic DNA was extracted. The LAMP technique was performed using specific primers targeting the ITS2 gene of C. albicans. The analytical sensitivity and specificity of LAMP were measured using a tenfold serial dilution prepared from extracted DNA from standard C. albicans strain from 1 ng to 1 fg and the DNA samples of other clinical Candida species and three non-Candida yeast. Out of 70 yeast samples analyzed by LAMP technique, 24 samples (34.3%) were positive for C. albicans. Comparison of the results showed that the CHROMagar Candida and germ tube production methods are quite consistent with the LAMP technique, while the agreement amount between the results of carbohydrate assimilation and chlamydoconidia generation assays and LAMP technique was 98.5% and 72.8%, respectively. The detection limits of the LAMP assay were 10 fg of the DNA from the standard C. albicans strain. No amplification was observed in the DNA samples of other yeast species and only the DNA sample of standard C. albicans strain was amplified. Based on the results, it can be concluded that the LAMP method is as specific and precise as common diagnostic methods, but is faster, easier deployable or more sensitive. Therefore, this method can be used as a suitable complementary assay for Candida diagnosis in medical diagnostic laboratories and field conditions.

Entities:  

Keywords:  Candida albicans; Conventional diagnostic methods; Diagnosis; LAMP technique

Mesh:

Substances:

Year:  2019        PMID: 31641798     DOI: 10.1007/s00203-019-01736-7

Source DB:  PubMed          Journal:  Arch Microbiol        ISSN: 0302-8933            Impact factor:   2.552


  9 in total

Review 1.  The Evolving Landscape of Fungal Diagnostics, Current and Emerging Microbiological Approaches.

Authors:  Zoe Freeman Weiss; Armando Leon; Sophia Koo
Journal:  J Fungi (Basel)       Date:  2021-02-09

2.  Development of loop-mediated isothermal amplification (LAMP) assay using SYBR safe and gold-nanoparticle probe for detection of Leishmania in HIV patients.

Authors:  Toon Ruang-Areerate; Charanyarut Sukphattanaudomchoke; Thanyapit Thita; Saovanee Leelayoova; Phunlerd Piyaraj; Mathirut Mungthin; Patcharapan Suwannin; Duangporn Polpanich; Tienrat Tangchaikeeree; Kulachart Jangpatarapongsa; Kiattawee Choowongkomon; Suradej Siripattanapipong
Journal:  Sci Rep       Date:  2021-06-09       Impact factor: 4.379

3.  Investigation of LAMP Technique in Diagnosis Type of Plasmodium Species in Anopheles Mosquitoes :A Fast and Practical Technique to Detect Malaria Pathogens in the Field.

Authors:  Hadi Mirahmadi; Nadia Kazemipour; Anis Yazdiani; Ahmad Mehravaran; Hamid Reza Basseri; Leili Mohammadi; Ebrahim Alijani
Journal:  Ethiop J Health Sci       Date:  2021-07

4.  Development of a Simple DNA Extraction Method and Candida Pan Loop-Mediated Isothermal Amplification Assay for Diagnosis of Candidemia.

Authors:  Da Hye Lim; Hyunseul Jee; Kyung Chul Moon; Chae Seung Lim; Woong Sik Jang
Journal:  Pathogens       Date:  2022-01-18

5.  Recombinant polymerase amplification combined with lateral flow strips for the detection of deep-seated Candida krusei infections.

Authors:  Mengdi Zhao; Xizhen Wang; Kun Wang; Yuanyuan Li; Yan Wang; Ping Zhou; Lei Wang; Wenjun Zhu
Journal:  Front Cell Infect Microbiol       Date:  2022-07-29       Impact factor: 6.073

6.  Establishment of a rapid diagnosis method for Candida glabrata based on the ITS2 gene using recombinase polymerase amplification combined with lateral flow strips.

Authors:  Kun Wang; Li Huo; Yuanyuan Li; Lihua Zhu; Yan Wang; Lei Wang
Journal:  Front Cell Infect Microbiol       Date:  2022-07-28       Impact factor: 6.073

7.  Distance-based paper device using combined SYBR safe and gold nanoparticle probe LAMP assay to detect Leishmania among patients with HIV.

Authors:  Toon Ruang-Areerate; Natkrittaya Saengsawang; Panthita Ruang-Areerate; Nalin Ratnarathorn; Thanyapit Thita; Saovanee Leelayoova; Suradej Siripattanapipong; Kiattawee Choowongkomon; Wijitar Dungchai
Journal:  Sci Rep       Date:  2022-08-26       Impact factor: 4.996

8.  Accurate and rapid detection of Fasciola hepatica copro-DNA in sheep using loop-mediated isothermal amplification (LAMP) technique.

Authors:  Siamak Amiri; Bahar Shemshadi; Saloomeh Shirali; Farnaz Kheirandish; Shirzad Fallahi
Journal:  Vet Med Sci       Date:  2021-02-24

Review 9.  Molecular Diagnosis of Yeast Infections.

Authors:  P Lewis White; Jessica S Price; Alan Cordey; Matthijs Backx
Journal:  Curr Fungal Infect Rep       Date:  2021-06-18
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.