Literature DB >> 31613688

The Effect of Aging on Aerosol Bolus Deposition in the Healthy Adult Lung: A 19-Year Longitudinal Study.

Chantal Darquenne1, G Kim Prisk1.   

Abstract

Background: While it is recognized that peripheral lung structure and ventilation heterogeneity change with age, the effects of age on aerosol deposition in the healthy adult lung is largely unknown.
Methods: A series of aerosol bolus inhalations were repeatedly performed in four healthy subjects over a period of 19 years (years = 0, 9, 15 and 19). For each series, a bolus of 1 μm particles was inhaled at penetration volumes (Vp) ranging from 200 to 1200 mL. Aerosol bolus deposition (DE), dispersion (H), and mode shift (MS) were calculated along with the rate of increase in these parameters with increasing Vp (slope-DE, slope-H, and slope-MS).
Results: Slope-DE significantly increased from 0.040 ± 0.014 (mean ± standard deviation) at year 0 to 0.069 ± 0.007%/mL at year 19 (p = 0.02) with no significant difference in DE at shallow depth (Vp = 200 mL; 14% ± 4% at year 0 vs. 15% ± 7% at year 19, p = 0.25). There was no significant effect of age on either slope-H (0.44 ± 0.05 at year 0 vs. 0.47 ± 0.09 mL/mL at year 19, p = 0.6) or dispersion at shallow depth (192 ± 36 mL at year 0 vs. 220 ± 54 mL at year 19, p = 0.2). Slope-MS became significantly more negative with increasing age (-0.096 ± 0.044 at year 0 vs. -0.171 ± 0.027 mL/mL at year 19, p = 0.001) with no significant difference in MS at shallow depth (12 ± 10 at year 0 vs. 7 ± 15 mL at year 19, p = 0.3). Conclusions: These data suggest that (1) peripheral deposition increases with aging in the healthy lung, likely as a result of increasing closing volume with age; (2) alterations in the mechanical properties of healthy adult lungs with age occur uniformly; and (3) the significant increase in the magnitude of MS-slope with age is likely due to the concomitant increase in peripheral deposition and possible alterations in flow sequencing.

Keywords:  aerosol bolus inhalation; aging; human lung; particle deposition

Mesh:

Substances:

Year:  2019        PMID: 31613688      PMCID: PMC7301329          DOI: 10.1089/jamp.2019.1566

Source DB:  PubMed          Journal:  J Aerosol Med Pulm Drug Deliv        ISSN: 1941-2711            Impact factor:   2.849


  19 in total

1.  Dispersion of 0.5- to 2-micron aerosol in microG and hypergravity as a probe of convective inhomogeneity in the lung.

Authors:  C Darquenne; J B West; G K Prisk
Journal:  J Appl Physiol (1985)       Date:  1999-04

2.  Mode shift of an inhaled aerosol bolus is correlated with flow sequencing in the human lung.

Authors:  Christopher N Mills; Chantal Darquenne; G Kim Prisk
Journal:  J Appl Physiol (1985)       Date:  2002-03

Review 3.  Aerosols as diagnostic tools.

Authors:  P J Anderson; M B Dolovich
Journal:  J Aerosol Med       Date:  1994

4.  Deposition of inhaled particles in the human lung is more peripheral in lunar than in normal gravity.

Authors:  Chantal Darquenne; G Kim Prisk
Journal:  Eur J Appl Physiol       Date:  2008-05-17       Impact factor: 3.078

5.  Deposition and dispersion of 1-micrometer aerosol boluses in the human lung: effect of micro- and hypergravity.

Authors:  C Darquenne; J B West; G K Prisk
Journal:  J Appl Physiol (1985)       Date:  1998-10

6.  Variability of fine particle deposition in healthy adults: effect of age and gender.

Authors:  W D Bennett; K L Zeman; C Kim
Journal:  Am J Respir Crit Care Med       Date:  1996-05       Impact factor: 21.405

7.  Convective mixing in human respiratory tract: estimates with aerosol boli.

Authors:  J Heyder; J D Blanchard; H A Feldman; J D Brain
Journal:  J Appl Physiol (1985)       Date:  1988-03

8.  Detection of small airway dysfunction in asymptomatic smokers using aerosol bolus behavior.

Authors:  P J Anderson; K G Hardy; L P Gann; R Cole; F C Hiller
Journal:  Am J Respir Crit Care Med       Date:  1994-10       Impact factor: 21.405

9.  Sensitivity of aerosol bolus behavior to methacholine-induced bronchoconstriction.

Authors:  K G Hardy; L P Gann; K B Tennal; R Walls; F C Hiller; P J Anderson
Journal:  Chest       Date:  1998-08       Impact factor: 9.410

10.  Deposition efficiency of inhaled particles (15-5000 nm) related to breathing pattern and lung function: an experimental study in healthy children and adults.

Authors:  Jenny Rissler; Anders Gudmundsson; Hanna Nicklasson; Erik Swietlicki; Per Wollmer; Jakob Löndahl
Journal:  Part Fibre Toxicol       Date:  2017-04-08       Impact factor: 9.400

View more
  1 in total

1.  Multiscale in silico lung modeling strategies for aerosol inhalation therapy and drug delivery.

Authors:  Pantelis Koullapis; Bo Ollson; Stavros C Kassinos; Josué Sznitman
Journal:  Curr Opin Biomed Eng       Date:  2019-11-13
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.