Literature DB >> 11842063

Mode shift of an inhaled aerosol bolus is correlated with flow sequencing in the human lung.

Christopher N Mills1, Chantal Darquenne, G Kim Prisk.   

Abstract

We studied the effects on aerosol bolus inhalations of small changes in convective inhomogeneity induced by posture change from upright to supine in nine normal subjects. Vital capacity single-breath nitrogen washout tests were used to determine ventilatory inhomogeneity change between postures. Relative to upright, supine phase III slope was increased 33 +/- 11% (mean +/- SE, P < 0.05) and phase IV height increased 25 +/- 11% (P < 0.05), consistent with an increase in convective inhomogeneity likely due to increases in flow sequencing. Subjects also performed 0.5-microm-particle bolus inhalations to penetration volumes (V(p)) between 150 and 1,200 ml during a standardized inhalation from residual volume to 1 liter above upright functional residual capacity. Mode shift (MS) in supine posture was more mouthward than upright at all V(p), changing by 11.6 ml at V(p) = 150 ml (P < 0.05) and 38.4 ml at V(p) = 1,200 ml (P < 0.05). MS and phase III slope changes correlated positively at deeper V(p). Deposition did not change at any V(p), suggesting that deposition did not cause the MS change. We propose that the MS change results from increased sequencing in supine vs. upright posture.

Entities:  

Keywords:  NASA Discipline Cardiopulmonary; Non-NASA Center

Mesh:

Substances:

Year:  2002        PMID: 11842063     DOI: 10.1152/japplphysiol.00655.2001

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  3 in total

1.  Aerosol deposition in the human lung periphery is increased by reduced-density gas breathing.

Authors:  Jonathan B Peterson; G Kim Prisk; Chantal Darquenne
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2008-06       Impact factor: 2.849

2.  Comparative Risks of Aldehyde Constituents in Cigarette Smoke Using Transient Computational Fluid Dynamics/Physiologically Based Pharmacokinetic Models of the Rat and Human Respiratory Tracts.

Authors:  Richard A Corley; Senthil Kabilan; Andrew P Kuprat; James P Carson; Richard E Jacob; Kevin R Minard; Justin G Teeguarden; Charles Timchalk; Sudhakar Pipavath; Robb Glenny; Daniel R Einstein
Journal:  Toxicol Sci       Date:  2015-04-08       Impact factor: 4.849

3.  The Effect of Aging on Aerosol Bolus Deposition in the Healthy Adult Lung: A 19-Year Longitudinal Study.

Authors:  Chantal Darquenne; G Kim Prisk
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2019-10-15       Impact factor: 2.849

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.