Tilman Bostel1,2,3, Ilias Sachpazidis4,5, Mona Splinter6,7, Nina Bougatf1,2,6, Tobias Fechter4,5, Constantinos Zamboglou4,5, Oliver Jäkel6,7, Peter E Huber1,2,6, Dimos Baltas4,5, Jürgen Debus1,2,6, Nils H Nicolay1,4,5.
Abstract
Background and purpose: To analyze deviations of the applied from the planned doses on a voxel-by-voxel basis for definitive prostate cancer radiotherapy depending on anatomic variations and imaging frequency. Materials and methods: Daily in-room CT imaging was performed in treatment position for 10 patients with prostate cancer undergoing intensity-modulated radiotherapy (340 fraction CTs). Applied fraction doses were recalculated on daily images, and voxel-wise dose accumulation was performed using a deformable registration algorithm. For weekly imaging, weekly position correction vectors were derived and used to rigidly register daily scans of that week to the planning CT scan prior to dose accumulation. Applied and prescribed doses were compared in dependence of the imaging frequency, and derived TCP and NTCP values were calculated.Entities:
Keywords: dosimetry; image-guided radiotherapy; organs-at-risk; prostate cancer; tumor control probability
Year: 2019 PMID: 31612106 PMCID: PMC6776888 DOI: 10.3389/fonc.2019.00940
Source DB: PubMed Journal: Front Oncol ISSN: 2234-943X Impact factor: 6.244
Figure 1Relative volumes of the CTV, rectum and bladder of each patient during the course of radiotherapy compared to the planning CT-based volumes. Error bars represent standard deviation.
Figure 2Relative deviation of the geometric center of the CTV between the planning CT and the fractional CTs in all three dimensions and resulting total displacement for each patient included in this analysis. Error bars represent standard deviation.
Figure 3Representative CT slices demonstrating the planned and applied doses using daily or weekly CT-based repositioning.
Figure 4Summary dose-volume histograms for the CTV (blue line), rectum (red line) and bladder (green line) for treatment plans (upper panel) and accumulated doses after daily (middle panel) and weekly (lower panel) repositioning. Lighter-colored bands represent the 95% confidence interval of each dose-volume curve.
Average and standard deviation of differences between applied and planned dose-volume indices for daily or weekly CT-based repositioning.
| CTV | D98 (Gy) | −2.27 ± 5.05 | 0.54 | −4.24 ± 6.00 | 0.19 |
| D50 (Gy) | 0.13 ± 0.74 | 0.26 | 0.01 ± 0.75 | 0.36 | |
| Dmean (Gy) | −0.08 ± 1.05 | 0.61 | −0.47 ± 1.07 | 0.36 | |
| D2 (Gy) | −0.40 ± 0.83 | 0.42 | −0.83 ± 0.90 | ||
| V76.5 (%) | 0.09 ± 0.27 | 0.22 | 0.05 ± 0.26 | 0.36 | |
| EUD (Gy) | −0.39 ± 1.69 | 0.76 | −1.32 ± 2.54 | 0.42 | |
| gEUD (Gy) | −1.15 ± 3.77 | 0.76 | −3.31 ± 6.56 | 0.36 | |
| CI | 0.16 ± 0.61 | 0.54 | −0.35 ± 0.42 | ||
| COIN | 0.06 ± 0.12 | 0.13 | 0.09 ± 0.14 | 0.13 | |
| P+ | 0.00 ± 0.02 | 0.31 | 0.02 ± 0.04 | 0.19 | |
| Bladder | D50 (Gy) | 2.78 ± 5.88 | 0.10 | 1.84 ± 5.67 | 0.08 |
| D70 (Gy) | 1.55 ± 5.90 | 0.10 | 1.18 ± 5.91 | 0.10 | |
| Dmean (Gy) | 1.40 ± 4.60 | 0.19 | 0.15 ± 4.98 | 0.61 | |
| D2 (Gy) | −2.34 ± 6.06 | 0.22 | −4.55 ± 8.48 | ||
| V75 (%) | −0.01 ± 0.04 | 0.68 | −0.04 ± 0.05 | ||
| V70 (%) | 0.00 ± 0.05 | 1.00 | −0.03 ± 0.06 | 0.19 | |
| V55 (%) | 0.01 ± 0.06 | 0.42 | −0.01 ± 0.07 | 0.92 | |
| V45 (%) | 0.01 ± 0.06 | 0.48 | 0.00 ± 0.07 | 1.00 | |
| EUD (Gy) | −0.94 ± 3.95 | 0.68 | −3.43 ± 5.44 | 0.22 | |
| gEUD (Gy) | −1.42 ± 4.76 | 0.68 | −4.65 ± 6.59 | 0.08 | |
| Rectum | D50 (Gy) | 0.41 ± 3.73 | 0.76 | 2.78 ± 4.10 | 0.07 |
| D70 (Gy) | 0.38 ± 2.41 | 0.84 | 0.63 ± 3.55 | 0.48 | |
| Dmean (Gy) | −0.12 ± 3.85 | 0.61 | 0.89 ± 3.58 | 0.42 | |
| D2 (Gy) | −1.54 ± 2.91 | 0.08 | −2.04 ± 2.77 | ||
| V75 (%) | 0.01 ± 0.07 | 0.48 | −0.01 ± 0.06 | 0.76 | |
| V70 (%) | −0.01 ± 0.08 | 0.41 | −0.01 ± 0.09 | 1.00 | |
| V50 (%) | −0.01 ± 0.09 | 0.31 | 0.01 ± 0.09 | 0.84 | |
| V40 (%) | −0.01 ± 0.08 | 0.68 | 0.02 ± 0.07 | 0.22 | |
| EUD (Gy) | −1.32 ± 5.28 | 0.31 | −1.18 ± 5.08 | 0.54 | |
| gEUD (Gy) | −1.75 ± 6.46 | 0.22 | −1.87 ± 6.28 | 0.48 |
Negative values represent decreases in accumulated doses. Bold values indicate statistically significant.
Figure 5Box-plot diagrams for TCP, bladder and rectal NTCP and P+ values derived from the planned and accumulated doses.
Figure 6Box-plot diagram for the gamma analyses regarding daily and weekly imaging.