Literature DB >> 31611499

Stable Hemodynamics within "No-Touch" Saphenous Vein Graft.

Qin Jiang1,2, Yan Yang2, Hansong Sun2, Yue Tang2, Feng Lv2, Shengshou Hu2.   

Abstract

PURPOSE: To investigate the hemodynamics characteristics of the "no-touch" saphenous vein graft (SVG) conduits by nicardipine intraluminal administration in vivo experiment.
METHODS: A total of 59 consecutive patients were enrolled and underwent a sequential SVG to three non-left anterior descending (LAD) targets with the average runoff ≤2 mm, 30 with "no-touch" harvest technique (group A) and 29 with conventional preparation (group B). The patients were subject to nicardipine intraluminal injection during off-pump coronary artery bypass grafting (CABG) procedure. The intraoperative flow was measured with the ultrasonic transit time flow meter (TTFM), and the graft patency testified by multi-detector computed tomography (MDCT) angiography, respectively.
RESULTS: The baseline blood flow was higher in group A than that in group B (p <0.05). However, the increases in blood flow of SVG conduits in group A were lower than those in group B with 19.7 ± 5.9 vs. 35.4 ± 9.2 mL/min, 14.8 ± 5.6 vs. 23.1 ± 6.8 mL/min, 6.6 ± 2.1 vs. 11.2 ± 4.3 mL/min before the first, second, and third anastomose after nicardipine intraluminal administration, respectively (all p <0.01).
CONCLUSIONS: No-touch SVGs were associated with higher baseline blood flow and less rises after nicardipine intraluminal administration during off-pump CABG procedure compared with conventional preparation. The no-touch SVGs seemed to be less spastic and well-tolerated on flow dilatation.

Entities:  

Keywords:  nicardipine; no-touch technique; off-pump coronary artery bypass; saphenous vein

Mesh:

Substances:

Year:  2019        PMID: 31611499      PMCID: PMC7184034          DOI: 10.5761/atcs.oa.19-00156

Source DB:  PubMed          Journal:  Ann Thorac Cardiovasc Surg        ISSN: 1341-1098            Impact factor:   1.520


  24 in total

1.  The "no-touch" harvesting technique for vein grafts in coronary artery bypass surgery preserves an intact vasa vasorum.

Authors:  Mats Dreifaldt; Domingos S R Souza; Andrzej Loesch; John R Muddle; Mats G Karlsson; Derek Filbey; Lennart Bodin; Lars Norgren; Michael R Dashwood
Journal:  J Thorac Cardiovasc Surg       Date:  2010-04-09       Impact factor: 5.209

2.  The impact of sequential versus single anastomoses on flow characteristics and mid-term patency of saphenous vein grafts in coronary bypass grafting.

Authors:  Hee Jung Kim; Taek Yeon Lee; Joon Bum Kim; Won Chul Cho; Sung Ho Jung; Cheol Hyun Chung; Jae Won Lee; Suk Jung Choo
Journal:  J Thorac Cardiovasc Surg       Date:  2010-07-02       Impact factor: 5.209

3.  Remote ischaemic preconditioning ameliorates sinus rhythm restoration rate through Cox maze radiofrequency procedure associated with inflammation reaction reduction.

Authors:  Qin Jiang; Bo Xiang; Haitao Wang; Keli Huang; Hong Kong; Shengshou Hu
Journal:  Basic Res Cardiol       Date:  2019-03-05       Impact factor: 17.165

Review 4.  Saphenous vein graft failure after coronary artery bypass surgery: pathophysiology, management, and future directions.

Authors:  Ralf E Harskamp; Renato D Lopes; Clinton E Baisden; Robbert J de Winter; John H Alexander
Journal:  Ann Surg       Date:  2013-05       Impact factor: 12.969

5.  Slower progression of atherosclerosis in vein grafts harvested with 'no touch' technique compared with conventional harvesting technique in coronary artery bypass grafting: an angiographic and intravascular ultrasound study.

Authors:  Benny L Johansson; Domingos S R Souza; Lennart Bodin; Derek Filbey; Andrzej Loesch; Håkan Geijer; Leif Bojö
Journal:  Eur J Cardiothorac Surg       Date:  2010-04-01       Impact factor: 4.191

6.  Comparison of conventional and no-touch techniques in harvesting saphenous vein for coronary artery bypass grafting in view of endothelial damage.

Authors:  Onur Sen; Suheyla Gonca; Seyhun Solakoglu; Hakki Dalcik; Cannur Dalcik; Ahmet Ozkara
Journal:  Heart Surg Forum       Date:  2013-08-01       Impact factor: 0.676

Review 7.  The saphenous vein as a bypass conduit: the potential role of vascular nerves in graft performance.

Authors:  Michael R Dashwood; Andrzej Loesch
Journal:  Curr Vasc Pharmacol       Date:  2009-01       Impact factor: 2.719

8.  The no-touch saphenous vein for coronary artery bypass grafting maintains a patency, after 16 years, comparable to the left internal thoracic artery: A randomized trial.

Authors:  Ninos Samano; Håkan Geijer; Mats Liden; Stephen Fremes; Lennart Bodin; Domingos Souza
Journal:  J Thorac Cardiovasc Surg       Date:  2015-07-15       Impact factor: 5.209

9.  The Risk Factor Analysis for the Late Graft Failure of Radial Artery Graft in Coronary Artery Bypass Grafting.

Authors:  Mitsuharu Hosono; Takashi Murakami; Hidekazu Hirai; Yasuyuki Sasaki; Shigefumi Suehiro; Toshihiko Shibata
Journal:  Ann Thorac Cardiovasc Surg       Date:  2018-08-17       Impact factor: 1.520

Review 10.  Role of PVAT in coronary atherosclerosis and vein graft patency: friend or foe?

Authors:  M S Fernández-Alfonso; M Gil-Ortega; I Aranguez; D Souza; M Dreifaldt; B Somoza; M R Dashwood
Journal:  Br J Pharmacol       Date:  2017-03-02       Impact factor: 8.739

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.