Literature DB >> 31610396

On-line in-tube solid phase microextraction coupled to capillary liquid chromatography-diode array detection for the analysis of caffeine and its metabolites in small amounts of biological samples.

H D Ponce-Rodríguez1, A A García-Robles2, P Sáenz-González2, J Verdú-Andrés3, P Campíns-Falcó4.   

Abstract

In-tube solid phase microextraction (IT-SPME) coupled on-line to capillary liquid chromatography with diode array detection provides a simple and fast analytical methodology for the simultaneous quantitation of caffeine and its three primary metabolites (theobromine, paraxanthine and theophylline) in micro samples of serum, saliva and urine matrices. The sample amount required for one analysis was only 2.5 μL of saliva, 6.25 μL of serum or 40 μL of urine, a requirement for its implementation in a hospital laboratory for preterm newborns, where sample availability is a major problem. In standard conditions, 25 μL of diluted saliva or serum (or 100 μL of urine) were processed by IT-SPME in 30 cm of commercially available capillary GC column coated with ZB-FFAP (100% nitroterephthalic modified polyethylene glycol). The retained compounds were desorbed from the IT-SPME capillary by the mobile phase (a gradient mixture of water and methanol) and the separation was carried out in a C18 column (150 mm × 0.5 mm i.d., 5 μm particle size). Analytes eluted before 14 min, at a flow rate of 15 μL min-1, and were detected by absorbance at 275 nm. The calibration graphs presented good linearity (R2 > 0.99), without the presence of matrix effect, and recoveries between 84 and 112% were obtained. Limits of detection (S/N = 3) were 0.1 μg·mL-1 in serum and 0.5 μg·mL-1 in saliva and urine samples, for all compounds, and the intra- and inter-day variation coefficients (n = 3) were between 3 and 17%. Analytical figures of merit were similar to those proposed by other methodologies, but using lower sample volume and a faster and simpler sample treatment and analysis. Paired samples of serum and saliva from preterm newborns treated with caffeine at the pediatric intensive care unit were analyzed by the method, with statistically equivalent results for caffeine concentrations.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Biological samples; Capillary liquid chromatography; In-tube solid-phase microextraction; Trimethylxanthines

Mesh:

Substances:

Year:  2019        PMID: 31610396     DOI: 10.1016/j.jpba.2019.112914

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  4 in total

1.  The association of salivary caffeine levels with serum concentrations in premature infants with apnea of prematurity.

Authors:  Ana García-Robles; Álvaro Solaz-García; Jorge Verdú-Andrés; José Luis Poveda Andrés; Antonio José Cañada-Martínez; Consuelo Cháfer Pericás; Henry Daniel Ponce-Rodriguez; Máximo Vento; Pilar Sáenz González
Journal:  Eur J Pediatr       Date:  2022-09-28       Impact factor: 3.860

2.  New Potentiometric Screen-Printed Platforms Modified with Reduced Graphene Oxide and Based on Man-Made Imprinted Receptors for Caffeine Assessment.

Authors:  Hisham S M Abd-Rabboh; Abdel El-Galil E Amr; Abdulrahman A Almehizia; Ahmed M Naglah; Ayman H Kamel
Journal:  Polymers (Basel)       Date:  2022-05-10       Impact factor: 4.967

Review 3.  Bioanalytical HPLC Applications of In-Tube Solid Phase Microextraction: A Two-Decade Overview.

Authors:  Natalia Manousi; Paraskevas D Tzanavaras; Constantinos K Zacharis
Journal:  Molecules       Date:  2020-04-30       Impact factor: 4.411

Review 4.  Innovations in Extractive Phases for In-Tube Solid-Phase Microextraction Coupled to Miniaturized Liquid Chromatography: A Critical Review.

Authors:  Henry Daniel Ponce-Rodríguez; Jorge Verdú-Andrés; Rosa Herráez-Hernández; Pilar Campíns-Falcó
Journal:  Molecules       Date:  2020-05-25       Impact factor: 4.411