Literature DB >> 31602045

Cancer detection rates and inter-examiner variability of MRI/TRUS fusion targeted biopsy and systematic transrectal biopsy.

Miroslav Zalesky1,2, Jiri Stejskal1, Ivo Minarik3, Vanda Adamcova1, Marek Babjuk3, Roman Zachoval1,2.   

Abstract

BACKGROUND: Software-based MRI/TRUS fusion biopsy depends on the coordination of several steps, and inter-examiner differences could influence the results. The aim of this bicentric prospective study was to compare the detection rates of MRI/TRUS fusion targeted biopsy (TG) and systematic biopsy (SB), and the detection rates of examiners with different levels of previous experience in prostate biopsy.
METHODS: A total of 419 patients underwent MRI based on a suspicion of prostate cancer with elevated PSA levels. MRI was positive in 395 patients (221 in the first biopsy group [FB] and 174 in the repeated biopsy group [RB]). A subsequent TG, followed by a SB, was performed on these patients by four different examiners.
RESULTS: In the detection of clinically significant prostate cancer, a significant difference was found for TG+SB against SB in the RB group (35.1% vs. 25.3%, P=0.047). In the detection of clinically insignificant prostate cancer, the SB had a significantly higher detection rate than TG in both subgroups (FB: 11.9% vs. 4.7%, P=0.008; RB: 13.8% vs. 6.9%, P=0.034). A significant difference was found between the four examiners in the FB for TG (P=0.028), SB (P=0.036), and TG+SB (P=0.017).
CONCLUSION: MRI/TRUS TG in combination with SB had significantly higher detection rates than SB in the RB group only. Differences in detection rates between examiners were dependent on the level of previous experience with TRUS guided biopsy.

Entities:  

Keywords:  biopsy; diagnostic imaging; fusion; magnetic resonance; prostate cancer

Mesh:

Year:  2019        PMID: 31602045     DOI: 10.5507/bp.2019.050

Source DB:  PubMed          Journal:  Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub        ISSN: 1213-8118            Impact factor:   1.245


  2 in total

1.  Evidence-based guideline recommendations on multiparametric magnetic resonance imaging in the diagnosis of clinically significant prostate cancer: A Cancer Care Ontario updated clinical practice guideline.

Authors:  Masoom A Haider; Judy Brown; Jospeh L K Chin; Nauthan Perlis; Nicola Schieda; Andrew Loblaw
Journal:  Can Urol Assoc J       Date:  2022-02       Impact factor: 1.862

2.  A prospective study on inter-operator variability in semi-robotic software-based MRI/TRUS-fusion targeted prostate biopsies.

Authors:  Manuel Ritter; Niklas Westhoff; Fabian Derigs; Samuel Doryumu; Fabian Tollens; Dominik Nörenberg; Manuel Neuberger; Jost von Hardenberg; Maurice Stephan Michel
Journal:  World J Urol       Date:  2021-11-26       Impact factor: 4.226

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.