Literature DB >> 31595320

Effect of different attachment geometries on the mechanical load exerted by PET‑G aligners during derotation of mandibular canines : An in vitro study.

F Elkholy1, B Mikhaiel2, S Repky3, F Schmidt4, B G Lapatki4.   

Abstract

AIM: Derotation of rounded teeth has proved difficult for aligners to achieve. In this study, we investigated the effect of aligner attachment geometry on the three-dimensional (3D) force and moment (F/M) values exerted during derotation of a mandibular canine.
MATERIALS AND METHODS: The experiment setup comprised an acrylic mandibular arch model with a separated right canine (tooth 43) mounted on a hexapod via a 3D F/M sensor. Polyethylene terephthalate glycol (PET‑G) aligners with thicknesses of 0.5, 0.625, and 0.75 mm were tested in combination with quarter-sphere, vertical-ellipsoid, and pyramidal attachments bonded to tooth 43. The experimentally measured movement consisted of mesio- and distorotation of tooth 43 in 1° steps up to ±15° in each direction.
RESULTS: Compared with no attachment, vertical-ellipsoid and quarter-sphere attachments increased the rotational moment by a median factor of 1.5-12.3. Moment increases for pyramidal attachments were significantly smaller (Mann-Whitney U‑test, p < 0.05). Quarter-sphere attachments inhibited the intrusive forces up to 6.07° distorotation, whereas the intrusion prevention range for most aligner attachment combinations was significantly smaller (2.95° for vertical-ellipsoid and 2.88° for pyramidal attachments; Mann-Whitney U‑test, p < 0.05). None of the attachment geometries could completely prevent intrusive forces during mesiorotation.
CONCLUSION: The quarter-sphere geometry had the best overall mechanical properties because it induced relatively high rotational moment increases and counteracted unwanted intrusive forces most effectively of all three geometries. The determined maximum attachment dislodgement and intrusion prevention angles of approximately 6° provide a guide to determining setup increments for mandibular canine derotation.

Entities:  

Keywords:  Attachments; Cuspid; Force; Moment; Orthodontic appliances; Thermoplastic appliance

Mesh:

Substances:

Year:  2019        PMID: 31595320     DOI: 10.1007/s00056-019-00193-7

Source DB:  PubMed          Journal:  J Orofac Orthop        ISSN: 1434-5293            Impact factor:   1.938


  12 in total

1.  Torquing an upper central incisor with aligners--acting forces and biomechanical principles.

Authors:  Wolfram Hahn; Antonia Zapf; Henning Dathe; Julia Fialka-Fricke; Susanne Fricke-Zech; Rudolf Gruber; Dietmar Kubein-Meesenburg; Reza Sadat-Khonsari
Journal:  Eur J Orthod       Date:  2010-05-12       Impact factor: 3.075

2.  Computer-aided analysis of the biomechanics of tooth movements.

Authors:  C Bourauel; L Keilig; A Rahimi; S Reimann; A Ziegler; A Jäger
Journal:  Int J Comput Dent       Date:  2007-01       Impact factor: 1.883

3.  The clear plastic appliance: a biomechanical point of view.

Authors:  Naphtali Brezniak
Journal:  Angle Orthod       Date:  2008-03       Impact factor: 2.079

4.  Dynamic stress relaxation of orthodontic thermoplastic materials in a simulated oral environment.

Authors:  Dongyu Fang; Ning Zhang; Hui Chen; Yuxing Bai
Journal:  Dent Mater J       Date:  2013-11-15       Impact factor: 2.102

5.  Initial forces generated by three types of thermoplastic appliances on an upper central incisor during tipping.

Authors:  Wolfram Hahn; Julia Fialka-Fricke; Henning Dathe; Susanne Fricke-Zech; Antonia Zapf; Rudolf Gruber; Dietmar Kubein-Meesenburg; Reza Sadat-Khonsari
Journal:  Eur J Orthod       Date:  2009-06-12       Impact factor: 3.075

6.  Stress relaxation properties of four orthodontic aligner materials: A 24-hour in vitro study.

Authors:  Luca Lombardo; Elisa Martines; Valentina Mazzanti; Angela Arreghini; Francesco Mollica; Giuseppe Siciliani
Journal:  Angle Orthod       Date:  2016-06-17       Impact factor: 2.079

7.  Mechanical load exerted by PET-G aligners during mesial and distal derotation of a mandibular canine : An in vitro study.

Authors:  F Elkholy; B Mikhaiel; F Schmidt; B G Lapatki
Journal:  J Orofac Orthop       Date:  2017-09       Impact factor: 1.938

8.  How well does Invisalign work? A prospective clinical study evaluating the efficacy of tooth movement with Invisalign.

Authors:  Neal D Kravitz; Budi Kusnoto; Ellen BeGole; Ales Obrez; Brent Agran
Journal:  Am J Orthod Dentofacial Orthop       Date:  2009-01       Impact factor: 2.650

9.  Initial forces and moments delivered by removable thermoplastic appliances during rotation of an upper central incisor.

Authors:  Wolfram Hahn; Benjamin Engelke; Klaus Jung; Henning Dathe; Julia Fialka-Fricke; Dietmar Kubein-Meesenburg; Reza Sadat-Khonsari
Journal:  Angle Orthod       Date:  2010-03       Impact factor: 2.079

10.  Predictability of orthodontic movement with orthodontic aligners: a retrospective study.

Authors:  Luca Lombardo; Angela Arreghini; Fabio Ramina; Luis T Huanca Ghislanzoni; Giuseppe Siciliani
Journal:  Prog Orthod       Date:  2017-11-13       Impact factor: 2.750

View more
  5 in total

1.  Comparative mechanical testing for different orthodontic aligner materials over time - in vitro study.

Authors:  Clara-Marie Nowak; Ahmed Othman; Dragan-Alexander Ströbele; Constantin von See
Journal:  J Clin Exp Dent       Date:  2022-06-01

2.  Performance of Rigid and Soft Transfer Templates Using Viscous and Fluid Resin-Based Composites in the Attachment Bonding Process of Clear Aligners.

Authors:  Cristina Valeri; Angelo Aloisio; Stefano Mummolo; Vincenzo Quinzi
Journal:  Int J Dent       Date:  2022-02-12

3.  In Vitro Comparison of Different Invisalign® and 3Shape® Attachment Shapes to Control Premolar Rotation.

Authors:  Nikolaos Ferlias; Michel Dalstra; Marie A Cornelis; Paolo M Cattaneo
Journal:  Front Bioeng Biotechnol       Date:  2022-03-16

Review 4.  Effects of Composite Attachments on Orthodontic Clear Aligners Therapy: A Systematic Review.

Authors:  Riccardo Nucera; Carolina Dolci; Angela Mirea Bellocchio; Stefania Costa; Serena Barbera; Lorenzo Rustico; Marco Farronato; Angela Militi; Marco Portelli
Journal:  Materials (Basel)       Date:  2022-01-11       Impact factor: 3.623

5.  Predictability of rotational tooth movement with orthodontic aligners comparing software-based and achieved data: A systematic review and meta-analysis of observational studies.

Authors:  Despina Koletsi; Anna Iliadi; Theodore Eliades
Journal:  J Orthod       Date:  2021-06-27
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.