Literature DB >> 31570950

Effect of differences in serum creatinine estimation methodologies on estimated glomerular filtration rate.

Su-Chu Lee1, Lee-Moay Lim1,2, Eddy-Essen Chang1, Yi-Wen Chiu1,3, Shang-Jyh Hwang1,3, Hung-Chun Chen1,3.   

Abstract

INTRODUCTION: Serum creatinine is crucial in glomerular filtration rate (GFR) estimation. Various methods of measuring GFR have been developed, which vary in their ability to estimate the prevalence of chronic kidney disease (CKD) and predict consequences associated with CKD. The use of different laboratory devices also results in uncertainty in estimated GFR (eGFR). The purpose of our study was to discuss the effect of differences in laboratory devices on eGFR when performing serum creatinine measurements.
METHODS: 163 participants aged 51.22 ± 18.66 years were enrolled during a community health screening programme conducted on 18 June 2011. Samples were sent to four different hospitals using four different devices to check serum creatinine by the Jaffe and enzymatic creatinine methods.
RESULTS: Using Roche Cobas Integra 400, Beckman LX20, Hitachi 7180 and Toshiba TBA - c8000, the proportion of the population with eGFR < 60 mL/min/1.73 m2 was 11.04%, 6.75%, 20.25% and 20.86%, respectively. Moreover, 3.68% of the participants had eGFR < 60 mL/min/1.73 m2 in the laboratory when Roche Cobas Integra 400 was used with the enzymatic creatinine method and compensated Jaffe method.
CONCLUSION: Although standardisation of serum creatinine measurement has been achieved by using isotope dilution mass spectrometry, differences in measurement devices still cause substantial bias in the overall results. This affects the application of GFR in the estimation of CKD progression and outcomes associated with CKD. Copyright: © Singapore Medical Association.

Entities:  

Keywords:  glomerular filtration rate; laboratory devices; measurement; serum creatinine

Mesh:

Substances:

Year:  2019        PMID: 31570950      PMCID: PMC7911078          DOI: 10.11622/smedj.2019115

Source DB:  PubMed          Journal:  Singapore Med J        ISSN: 0037-5675            Impact factor:   1.858


  17 in total

1.  K/DOQI clinical practice guidelines for chronic kidney disease: evaluation, classification, and stratification.

Authors: 
Journal:  Am J Kidney Dis       Date:  2002-02       Impact factor: 8.860

2.  Chronic kidney disease as a risk factor for cardiovascular disease and all-cause mortality: a pooled analysis of community-based studies.

Authors:  Daniel E Weiner; Hocine Tighiouart; Manish G Amin; Paul C Stark; Bonnie MacLeod; John L Griffith; Deeb N Salem; Andrew S Levey; Mark J Sarnak
Journal:  J Am Soc Nephrol       Date:  2004-05       Impact factor: 10.121

Review 3.  Overview: increased cardiovascular risk in patients with minor renal dysfunction: an emerging issue with far-reaching consequences.

Authors:  Eberhard Ritz; William M McClellan
Journal:  J Am Soc Nephrol       Date:  2004-03       Impact factor: 10.121

4.  'United States Renal Data System 2011 Annual Data Report: Atlas of chronic kidney disease & end-stage renal disease in the United States.

Authors:  Allan J Collins; Robert N Foley; Blanche Chavers; David Gilbertson; Charles Herzog; Kirsten Johansen; Bertram Kasiske; Nancy Kutner; Jiannong Liu; Wendy St Peter; Haifeng Guo; Sally Gustafson; Brooke Heubner; Kenneth Lamb; Shuling Li; Suying Li; Yi Peng; Yang Qiu; Tricia Roberts; Melissa Skeans; Jon Snyder; Craig Solid; Bryn Thompson; Changchun Wang; Eric Weinhandl; David Zaun; Cheryl Arko; Shu-Cheng Chen; Frank Daniels; James Ebben; Eric Frazier; Christopher Hanzlik; Roger Johnson; Daniel Sheets; Xinyue Wang; Beth Forrest; Edward Constantini; Susan Everson; Paul Eggers; Lawrence Agodoa
Journal:  Am J Kidney Dis       Date:  2012-01       Impact factor: 8.860

5.  Comparison between ADVIA Chemistry systems Enzymatic Creatinine_2 method and ADVIA Chemistry systems Creatinine method (kinetic Jaffe method) for determining creatinine.

Authors:  Fernando J Hermida; María J Lorenzo; Aida Pérez; María Fernández; Olatz Sagastagoia; Concepción Magadán
Journal:  Scand J Clin Lab Invest       Date:  2014-07-02       Impact factor: 1.713

6.  Chronic kidney disease and automatic reporting of estimated glomerular filtration rate: a position statement.

Authors:  Timothy H Mathew
Journal:  Med J Aust       Date:  2005-08-01       Impact factor: 7.738

7.  Using standardized serum creatinine values in the modification of diet in renal disease study equation for estimating glomerular filtration rate.

Authors:  Andrew S Levey; Josef Coresh; Tom Greene; Lesley A Stevens; Yaping Lucy Zhang; Stephen Hendriksen; John W Kusek; Frederick Van Lente
Journal:  Ann Intern Med       Date:  2006-08-15       Impact factor: 25.391

8.  Cefoxitin falsely elevates creatinine levels.

Authors:  A J Saah; T R Koch; G L Drusano
Journal:  JAMA       Date:  1982-01-08       Impact factor: 56.272

9.  Spurious serum creatinine elevations in ketoacidosis.

Authors:  M E Molitch; E Rodman; C A Hirsch; E Dubinsky
Journal:  Ann Intern Med       Date:  1980-08       Impact factor: 25.391

Review 10.  Glomerular filtration rate measurement and prediction equations.

Authors:  Ariana Aguiar Soares; Tatiana Falcão Eyff; Raquel Barth Campani; Luciana Ritter; Joíza Lins Camargo; Sandra Pinho Silveiro
Journal:  Clin Chem Lab Med       Date:  2009       Impact factor: 3.694

View more
  2 in total

1.  Widespread kidney anomalies in children with Down syndrome.

Authors:  Lavinia Postolache; Afshin Parsa; Paolo Simoni; Grammatina Boitsios; Khalid Ismaili; Thierry Schurmans; Anne Monier; Georges Casimir; Adelin Albert; Cameron F Parsa
Journal:  Pediatr Nephrol       Date:  2022-02-03       Impact factor: 3.651

2.  Low-Osmolality Carbohydrate-Electrolyte Solution Ingestion Avoid Fluid Loss and Oxidative Stress After Exhaustive Endurance Exercise.

Authors:  Wen-Ching Huang; Yu-Tang Tung; Mai-Szu Wu; Ming-Che Liu; Tsai-Jung Lin; Ming-Ta Yang
Journal:  Antioxidants (Basel)       Date:  2020-04-20
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.