The effect different substrates have on the trueness and precision of eight different intraoral scanners.

Ethan Dutton1, Mark Ludlow2, Anthony Mennito2, Abigail Kelly3, Zachary Evans3, Alexander Culp4, Raymond Kessler3, Walter Renne2.   

Abstract

OBJECTIVE: This in vitro study compares the newest generation of intraoral scanners to their older counterparts, and tests whether material substrates affect the trueness and precision of intraoral scanners (IOS).
MATERIAL AND METHODS: A custom model, used as the reference standard, was fabricated with teeth composed of different dental materials. The reference standard scan was obtained using a three-dimensional (3D) optical scanner, the ATOS III. Experimental scans were obtained using eight different IOS, operated by experienced clinicians, using the manufacturer's recommended scanning strategy. A comprehensive metrology program, Geomagic Control X, was used to compare the reference standard scan with the experimental scans.
RESULTS: For all scanners tested, except Trios3, the substrate does influence the trueness and precision of the scan. Furthermore, differences exist when comparing the same substrate across different scanners with some of the latest generation scanners clearly leaping ahead of the older generation regarding both trueness and precision.
CONCLUSIONS: Substrate type affects the trueness and precision of a scan. Active Triangulation scanners are more sensitive to substrate differences than their parallel confocal counterparts. Some scanners scan certain substrates better, but in general the new generation of scanners outperforms the old, across all substrates. CLINICAL SIGNIFICANCE: The substrates being scanned play an import role in the trueness and precision of the 3D model. The new generation of scanners is remarkably accurate across all substrates and for complete-arch scanning.
© 2019 Wiley Periodicals, Inc.

Keywords:  accuracy; dental materials; digital dentistry; intraoral scanner; precision

Year:  2019        PMID: 31568660     DOI: 10.1111/jerd.12528

Source DB:  PubMed          Journal:  J Esthet Restor Dent        ISSN: 1496-4155            Impact factor:   2.843


  5 in total

Review 1.  Comparison of the Accuracy of 3D Images Obtained fromDifferent Types of Scanners: A Systematic Review.

Authors:  Dorota Kustrzycka; Tim Marschang; Marcin Mikulewicz; Wojciech Grzebieluch
Journal:  J Healthc Eng       Date:  2020-12-14       Impact factor: 2.682

2.  In-vitro evaluation of marginal and internal fit of 3-unit monolithic zirconia restorations fabricated using digital scanning technologies.

Authors:  Çise Özal; Mutahhar Ulusoy
Journal:  J Adv Prosthodont       Date:  2021-12-22       Impact factor: 1.904

3.  The Effect of Scanning Strategy on Intraoral Scanner's Accuracy.

Authors:  Nikolaos A Gavounelis; Chrysoula-Maria C Gogola; Demetrios J Halazonetis
Journal:  Dent J (Basel)       Date:  2022-07-04

4.  Marginal and internal fit and intaglio surface trueness of interim crowns fabricated from tooth preparation of four finish line locations.

Authors:  Keunbada Son; Young-Tak Son; Ji-Min Lee; Kyu-Bok Lee
Journal:  Sci Rep       Date:  2021-07-06       Impact factor: 4.379

Review 5.  Ceramic Materials and Technologies Applied to Digital Works in Implant-Supported Restorative Dentistry.

Authors:  Se-Wook Pyo; Dae-Joon Kim; Jung-Suk Han; In-Sung Luke Yeo
Journal:  Materials (Basel)       Date:  2020-04-22       Impact factor: 3.623