Literature DB >> 31564882

Evaluating optic nerve diameter as a possible biomarker for disability in patients with multiple sclerosis.

Noha Abo Koraysha1, Nirmeen Kishk1, Amr Hassan1, Nehal M Samy El Gendy2, Hatem S Shehata1, Salsabil Abo Al-Azayem1, Yasmine Shawki Kamal1.   

Abstract

BACKGROUND AND
PURPOSE: The development of new biomarkers for multiple sclerosis (MS) is of paramount importance to improve our ability to predict disease progression and disability. The aim of this study was to evaluate the potential role of the optic nerve diameter (OND) measured by ultrasonography as a biomarker of early disability in patients with relapsing-remitting multiple sclerosis (RRMS).
METHODS: Forty-nine RRMS patients, 23 with a history of optic neuritis (MS-ON) and 26 without a history of optic neuritis (MS N-ON), and 50 age- and sex-matched healthy control subjects were included in the study. The OND and optic nerve sheath diameter (ONSD) were measured by transorbital sonography (TOS), and the retinal nerve fibre layer (RNFL) and ganglion cell complex (GCC) thicknesses were measured by optical coherence tomography (OCT) using the Optovue RTVue™ system (Optovue, Inc., Fremont, CA, USA).
RESULTS: There was no significant difference between the patient (whether ON or N-ON eyes) and control groups in either the OND (p=0.979) or the ONSD (p=0.911). However, patients with an expanded disability status scale (EDSS) score >2 had a significantly lower OND and RNFL thicknesses (p=0.014, p=0.010 respectively) than patients with an EDSS score ≤2. Statistical logistic regression revealed that OND was an independent predictor of EDSS>2 (p=0.044, OR =0.000, 95% CI=0.000-0.589).
CONCLUSION: The OND, as measured by ultrasonography, could be potentially used as a biomarker for the detection of early disability in RRMS patients.
© 2019 Koraysha et al.

Entities:  

Keywords:  OCT; RNFL; biomarker; multiple sclerosis; transorbital sonography

Year:  2019        PMID: 31564882      PMCID: PMC6735536          DOI: 10.2147/NDT.S216079

Source DB:  PubMed          Journal:  Neuropsychiatr Dis Treat        ISSN: 1176-6328            Impact factor:   2.570


Introduction

Multiple sclerosis (MS) is one of the leading disabling neurological diseases in young adults. Characteristically reliable biomarkers for every independent MS pathogenic factor are extremely important.1 Increasing evidence has demonstrated that neuronal and axonal damage within the central nervous system (CNS) contributes substantially to the development of permanent disability in patients with MS.2 Thus, reliable, economic and easily assessable complementary surrogate biomarkers for axonal degeneration and consequently disability remain to be identified.3 The optic nerve can serve as a useful clinical tool for studying these characteristics and can be used to measure and monitor the pathological process of the disease.4 Optical coherence tomography (OCT) is a non-contact machine that allows precise measurement of retinal layers thickness using infrared waves. Spectral domain (SD) technology has been used in more recent generations of ophthalmic OCT machines. SD-OCT systems are capable of providing more than 100 times faster scan speed with lower acquisition time. SD-OCT systems use an 850 nm wavelength, which provides better depth resolution. The higher speed, deeply penetrating wavelength provided high resolution, which, using special software algorithm allowed RNGL and GCC analysis.5 OCT is a potential tool for monitoring axonal loss in MS patients and is being investigated in several clinical researches.6,7 The most important parameters in OCT studies are the retinal nerve fibre layer (RNFL) thickness, which is a good measure of the axonal thickness at the optic disc, and the ganglion cell complex (GCC) thickness, which allows the quantification of both axonal loss and neuronal degeneration at the macula,8 probably because of retrograde trans-synaptic degeneration and the progressive loss of retinal ganglion cells, in addition to the more pronounced thinning caused by optic neuritis (ON), if present;9 Ganglion Cell Complex (GCC) revealed the summation of macular RNFL, GCL (ganglion cell layer: formed by ganglion cell body), and IPL(inner plexiform layer).10 The optic nerve is most commonly assessed by ophthalmoscopy and magnetic resonance imaging (MRI), but measurement of the optic nerve diameter (OND) by a simple ultrasound examination might permit a rough estimation of the extent of brain parenchymal involvement and the consequent global cerebral atrophy and disability in relapsing-remitting MS (RRMS) patients. The analysis of the diameter of the optic nerve showed that it is possible to detect its atrophy in the affected eyes (with ON) and, to a lesser extent, in the unaffected eyes of MS patients.11 The aim of this study was to evaluate the potential role of the OND determined by ultrasonography as a biomarker of early axonal loss and disability in patients with RRMS.

Subjects and methods

Subjects

This cross-sectional case-control study was conducted in 49 patients (17 males and 32 females; mean age: 28.96±9.5 years) diagnosed with RRMS according to the revised McDonald’s criteria with (MS-ON) or without a history of unilateral ON (MS N-ON).12 The patients were recruited from the Kasr Al-Ainy Multiple Sclerosis Unit (KAMSU), Cairo University Hospital, from January 2017 to September 2017. Fifty age- and sex-matched healthy volunteers were recruited from medical students and hospital employees as a control group. We excluded patients with progressive MS (whether primary or secondary), patients with a history of relapse in the last three months prior to enrolment, patients with a history of ocular surgery, glaucoma, diabetes, or hypertension, as these conditions may interfere with OCT findings, patients with a history of alcohol intake or a history of bilateral ON, whether simultaneous or sequential, and patients on Fingolimod for more than 6 months prior to recruitment, as it may cause macular oedema.

Methods

Clinical assessment

All patients had undergone thorough neurological, ophthalmological and disability evaluations using the expanded disability status scale (EDSS).13

Transorbital sonography (TOS)

All examinations were performed at the Neurosonology Unit, Neurology Department, Cairo University Hospital, by a single experienced neurosonographer (certified by the European Society of Neurosonology and Cerebral Haemodynamics “ENSCH”), who was blinded to the subjects’ clinical data throughout the entire study. TOS was performed using a Philips IU22 system with a linear L9 probe at 13 MHz obtained from California, USA. Subjects were examined in the supine position with the upper part of the body and the head elevated 20º to 30º degrees to avoid any pressure on the eye. They were asked to keep their eyes in a mid-position and to suppress eye movements. For safety, the mechanical index was reduced to 0.2. The probe was placed on the temporal part of the closed upper eyelid using a thick layer of sonography gel. The anterior part of the optic nerve was depicted in an axial plane showing the papillae and the optic nerve in its longitudinal course. The measured parameters were the OND and the optic nerve sheath diameter (ONSD), which were measured 3 mm behind the posterior edge of the globe in a horizontal plane.14 The optic nerve was visualized as a hypoechogenic structure beyond the retina surrounded by hyperechoic subarachnoid space and hypoechoic dura mater (Figure 1). In patients with no history of ON, two readings were recorded for one eye, and their mean value was calculated. In patients with a history of ON, the examination was performed twice, and the mean value was calculated. The affected eye in MS-ON group and only one eye from MS N-ON and control groups were included in the statistical analysis.
Figure 1

Sonographic measurement of the optic nerve diameter (black line) and the optic nerve sheath diameter (grey line), calculated by the distance between the two cursors measured 3 mm posterior to the globe (white line).

Sonographic measurement of the optic nerve diameter (black line) and the optic nerve sheath diameter (grey line), calculated by the distance between the two cursors measured 3 mm posterior to the globe (white line).

OCT

Spectral-domain OCT was performed using the Optovue RTVue™ system (Optovue Inc., Fremont, CA, USA). Two different protocols were used in the two eyes: the 1st was the macular map protocol, which allows rapid macular scanning for measurement of the GCC thickness; the 2nd was the peripapillary RNFL protocol. All examinations were performed at the Ophthalmology Department, Cairo University Hospital, by a single experienced ophthalmologist. The study protocols and data collection methods conformed to all local laws and were compliant with the principles of Declaration of Helsinki. The study was approved by the local ethical committee. Informed consent was provided by all patients upon enrolment in the study.

Statistical analysis

Data were coded and entered using the statistical package for the Social Sciences (SPSS) version 25 (IBM Corp., Armonk, NY, USA). Data was summarized using mean and standard deviation for quantitative variables and frequencies (number of cases) and relative frequencies (percentages) for categorical variables. Comparisons between groups were done using unpaired t test in normally distributed quantitative variables while non-parametric Mann-Whitney test was used for non-normally distributed quantitative variables.15 For comparing categorical data, Chi square (χ2) test was performed. Exact test was used instead when the expected frequency is less than 5.15 Correlations between quantitative variables were done using Spearman correlation coefficient.16 A receiver operating characteristic (ROC) curve was constructed, and the area under the curve (AUC) was analysed to detect the best cutoff value for the parameters for EDSS score detection. Logistic regression was done to detect independent predictors of EDSS>2.17 P-values less than 0.05 were considered as statistically significant. Graphs and tables were used to illustrate some information. Logistic regression was done to detect the independent factor reaching EDSS ˃2 as an outcome.

Results

Demographic and clinical characteristics

The patient group included 49 patients; 23 of these patients had a history of ON (MS-ON), and 26 had no history of ON (MS N-ON).Twenty-five patients had an EDSS score ≤2, and 24 patients had an EDSS score >2. An EDSS score of 2 was used as a cutoff value for early disability. The demographic and clinical characteristics of the patients in both groups are shown in Table 1.
Table 1

Summary of demographic and clinical characteristics of the participants

ItemsPatient group (n=49)Control group (n=50)
Age (years)28.96±9.529.86±6.33
Sex
 Male17 (34.7%)18 (36%)
 Female32 (65.3%)32 (64%)
Age at disease onset (years)23.8±7.72
History of unilateral ON
 Yes23 (46.9%)
 No26 (53.1%)
Number of relapses (mean±SD)3.57±1.68
Disease duration (years)5.06±4.64
EDSS score (mean±SD)2.347±1.07
 ≤225 (51.02%)
 >224 (49.98%)

Abbreviations: ON, optic neuritis; EDSS, expanded disability status scale.

Summary of demographic and clinical characteristics of the participants Abbreviations: ON, optic neuritis; EDSS, expanded disability status scale.

Results of TOS and OCT

As shown in Table 2, there was no significant difference between patients and controls in either the OND or ONSD. On the other hand, the RNFL and GCC were significantly thinner in the patient group than in the control group. The clinical and imaging results of the individual patients are summarised in Figure 2.
Table 2

TOS and OCT results in patient and control groups

Patients (n=49)Control (n=50)P-value
Mean ± SDMean ± SD
OND (mm)3±0.43±0.40.979
ONSD (mm)5.5±0.65.4±0.50.911
RNFL thickness (µm)96.53±12.65121.18±2.68<0.001*
GCC thickness (µm)84.10±9.66101.35±7.96<0.001*
OND/ONSD ratio0.56±0.050.56±0.060.882

Note: *P-value <0.05 considered statistically significant.

Abbreviations: OND, optic nerve diameter; ONSD, optic nerve sheath diameter; RNFL, retinal nerve fibre layer; GCC, ganglion cell complex.

Figure 2

Clinical, TOS and OCT data of the patients group.

Abbreviations: EDSS, expanded disability status scale; ON, optic nerve; RNFL, retinal nerve fibre layer.

Clinical, TOS and OCT data of the patients group. Abbreviations: EDSS, expanded disability status scale; ON, optic nerve; RNFL, retinal nerve fibre layer. TOS and OCT results in patient and control groups Note: *P-value <0.05 considered statistically significant. Abbreviations: OND, optic nerve diameter; ONSD, optic nerve sheath diameter; RNFL, retinal nerve fibre layer; GCC, ganglion cell complex.

Comparison between patients with EDSS scores ≤2 and >2

Patients with an EDSS score >2 had significantly a thinner OND and RNFL (p=0.014, p=0.010 respectively) than patients with an EDSS score ≤2 (Table 3).
Table 3

Results of TOS and OCT in the N-ON eyes of patients with EDSS scores ≤2 and >2

ItemsPatients with an EDSS score ≤2 (n=25)Patients with an EDSS score >2 (n=24)P-value
OND (mm)3.2±0.42.9±0.40.014*
ONSD (mm)5.6±0.65.3±0.60.194
RNFL thickness (µm)100.8±12.0191.7±11.80.010*
GCC thickness (µm)85.87±10.1282.1±8.90.175

Note: *P-value <0.05 considered statistically significant.

Abbreviations: EDSS, expanded disability status scale; OND, optic nerve diameter; ONSD, optic nerve sheath diameter; RNFL, retinal nerve fibre layer; GCC, ganglion cell complex.

Results of TOS and OCT in the N-ON eyes of patients with EDSS scores ≤2 and >2 Note: *P-value <0.05 considered statistically significant. Abbreviations: EDSS, expanded disability status scale; OND, optic nerve diameter; ONSD, optic nerve sheath diameter; RNFL, retinal nerve fibre layer; GCC, ganglion cell complex.

Results of TOS and OCT in ON and N-ON eyes

The RNFL and GCC were significantly thinner in ON eyes than in N-ON eyes (p=0.029, p=0.017, respectively); however, the OND and ONSD showed no significant differences between these subgroups (Table 4).
Table 4

Results of TOS and OCT in ON and N-ON eyes

ItemsON eyes (n=23)N-ON eyes (n=26)P-value
OND (mm)3.1±0.43±0.40.629
ONSD (mm)5.5±0.65.4±0.50.463
RNFL thickness (µm)92.22±14.85100.34±8.990.029*
GCC thickness (µm)80.66±1087.15±8.400.017*

Note: *P-value <0.05 considered statistically significant.

Abbreviations: EDSS, expanded disability status scale; OND, optic nerve diameter; ONSD, optic nerve sheath diameter; RNFL, retinal nerve fibre layer; GCC, ganglion cell complex.

Results of TOS and OCT in ON and N-ON eyes Note: *P-value <0.05 considered statistically significant. Abbreviations: EDSS, expanded disability status scale; OND, optic nerve diameter; ONSD, optic nerve sheath diameter; RNFL, retinal nerve fibre layer; GCC, ganglion cell complex. A receiver operating characteristic (ROC) curve was constructed, as shown in Figure 3, to determine the cutoff values for the RNFL and GCC thickness resulting in the highest sensitivity and specificity for the detection of patients with an EDSS score >2. According to the ROC curve, the cutoff value for the RNFL and GCC were 117.055 and 93.235 mm respectively meaning that patients with lesser values were more likely to have an EDSS score >2; this result indicates subtle progression with a sensitivity and specificity of 98% and 100%, respectively for RNFL; 85.7% and 91.8% respectively for GCC (Table 5).
Figure 3

ROC curve for the sensitivity and specificity of the RNFL and GCC thickness in the detection of an EDSS score >2.

Table 5

Cutoff values for the RNFL and GCC for detecting an EDSS score >2

Area Under the CurveP-value95% Confidence IntervalCut offSensitivity %Specificity %
Lower BoundUpper Bound
RNFL thickness (µm)0.993<0.001*0.9791.000117.05598100
GCC thickness (µm)0.934<0.001*0.8830.98593.23585.791.8

Note: *P-value <0.05 considered statistically significant.

Abbreviations: RNFL, retinal nerve fibre layer; GCC, ganglion cell complex.

ROC curve for the sensitivity and specificity of the RNFL and GCC thickness in the detection of an EDSS score >2. Cutoff values for the RNFL and GCC for detecting an EDSS score >2 Note: *P-value <0.05 considered statistically significant. Abbreviations: RNFL, retinal nerve fibre layer; GCC, ganglion cell complex. Statistical logistic regression was done to detect independent predictors of EDSS>2 among the demographic, clinical and imaging parameters. It had revealed that disease duration (p=0.023, OR=1.204, 95% CI=1.026–1.414), OND (p=0.044, OR=0.000, 95% CI=0.000–0.589) and RNFL thickness (p=0.026, OR=0.934, 95% CI=0.879–0.992) are independent predictors of EDSS>2 as shown in Table 6.
Table 6

Logistic regression to detect independent predictors of EDSS>2

P-valueOR95% Confidence Interval
LowerUpper
EDSS>2Disease Duration0.023*1.2041.0261.414
OND (mm)0.044*0.0000.0000.589
RNFL thickness (µm)0.026*0.9340.8790.992

Note: *P-value <0.05 considered statistically significant.

Abbreviations: OND, optic nerve diameter; GCC, ganglion cell complex.

Logistic regression to detect independent predictors of EDSS>2 Note: *P-value <0.05 considered statistically significant. Abbreviations: OND, optic nerve diameter; GCC, ganglion cell complex.

Discussion

Large numbers of biomarkers have been tested in the past few years for their ability to predict the response to therapy, disease course and progression, and outcome of MS. Axonal loss has been found to be a promising biomarker for MS. Axonal loss is the most important pathological factor that contributes to permanent disability in MS. Assessing axonal loss could be useful for monitoring disease evolution.18 RNFL thinning, as detected by OCT, has been established in many studies as a reliable biomarker of axonal loss, correlating adequately with brain atrophy measures.18–21 Numerous studies have found thinning of the RNFL not only in eyes with a previous episode of ON but also in the presumably asymptomatic contralateral eye of MS patients who had an episode of ON, as well as in MS patients who never had clinical acute ON.22–26 Moreover, several cross-sectional studies have reported these significant correlations between thinner RNFL and GCC values and higher EDSS scores in both RRMS and secondary progressive MS (SPMS) groups.27–29 Therefore, the presence of a significant correlation between both the RNFL thickness and the EDSS score supports the hypothesis that axonal damage occurs early in the disease course. However, TOS can be used as an alternative tool to OCT in the evaluation of optic nerves, especially with increasing numbers of experienced neurosonographers worldwide over the past few years. TOS has mainly been used to evaluate intracranial hypertension and has shown a correlation between an increased ONSD and increased intracranial pressure.30–32 One of the main advantages of TOS over OCT is its low cost, high accessibility and reproducibility, with minimal inter- and intra-observer variability.30–33 TOS also offers a sensitive, user-friendly, and reliable technique for detecting the ONSD. Many studies have demonstrated the utility of TOS in evaluating ON, showing increased an OND in the acute phase of MS.34–38 TOS was able to detect a significant thickening of the OND and ONSD in acute ON, which is probably due to inflammation with a subsequent increase in perineural subarachnoid fluid early in the disease course. A recent study has demonstrated that TOS is a reliable method for measuring ON atrophy in MS. However, the author recommended further studies to compare TOS with visual evoked potentials (VEPs) and OCT to confirm its usefulness in routine clinical practice.9 Our aim was to study the potential role of the OND and ONSD determined using ultrasound as early markers of axonal loss and disability in RRMS patients compared to metrics determined by OCT as well-established axonal loss biomarkers. Our results showed no significant difference in the OND or ONSD between RRMS patients (with or without a past history of ON) and healthy controls. These results are contradictory to those of a previous study that detected OND atrophy in eyes with ON and, to a lesser extent, in the unaffected eyes of MS patients compared to those of controls.39 This difference could be attributed to the fact that the OND measurement Carraro et al used was more proximal to detect the maximum diameter of the nerve. However, in our study, we measured the OND 3 mm from the retinal plane, where the optic nerve is thinner and less myelinated; as such, we might not be able to distinguish small differences in nerve thickness between MS patients and controls. Our sample size might have also been insufficient to reveal statistically significant differences. Additionally, some of our patients in the MSN-ON group could have had an attack of silent or unreported ON. Another possibility is that our subjects might have had mild ON that would not have affected the OND or caused only minimal atrophy.39 However, we found that patients with an EDSS score >2 had significantly smaller ONDs than those with an EDSS score ≤2. Statistical logistic regression was done to detect independent predictors of EDSS>2 among the demographic, clinical and imaging parameters. It had revealed that disease duration OND (p=0.044, OR=0.000, 95% CI=0.000–0.589) is an independent predictors of achieving EDSS>2. Collectively, our data may represent an indirect indicator for the potential role of the OND determined by sonography as a marker of detection of early disability in MS. To the best of our knowledge, there have been no published studies addressing the role of the sonographic OND as a potential marker of early disability in MS in comparison to OCT metrics. A recent multicentre study of 59 patients with RRMS confirmed our results, as it showed that the thickness of the optic nerve measured with TOS was correlated with the EDSS score and the duration of the disease without interference from a previous history of ON; however, they did not compare the TOS and OCT results.9 Our study had some limitations. First, there was a lack of normative values for the OND. Second, the use of TOS and OCT can only detect structural lesions; therefore, it would have been more beneficial to combine these methods with VEPs for better correlation between structural lesions and functional impairment (VEPs were determined but not at the same time of our study). In conclusion, the OND, as determined by ultrasonography, could be used as a potential biomarker for the detection of early disability in RRMS patients. Further studies may be needed to confirm our findings and to support this hypothesis. The early detection of disability can facilitate early interventions and consequently better outcomes and prognoses.
  35 in total

1.  Observer variation in the sonographic measurement of optic nerve sheath diameter in normal adults.

Authors:  S A Ballantyne; G O'Neill; R Hamilton; A S Hollman
Journal:  Eur J Ultrasound       Date:  2002-10

2.  Intra- and interobsever reliability of sonographic assessment of the optic nerve sheath diameter in healthy adults.

Authors:  Jochen Bäuerle; Piergiorgio Lochner; Manfred Kaps; Max Nedelmann
Journal:  J Neuroimaging       Date:  2010-12-01       Impact factor: 2.486

3.  Biostatistics 104: correlational analysis.

Authors:  Y H Chan
Journal:  Singapore Med J       Date:  2003-12       Impact factor: 1.858

Review 4.  B-mode transorbital ultrasononography for the diagnosis of acute optic neuritis. A systematic review.

Authors:  Piergiorgio Lochner; Maurizio A Leone; Lorenzo Coppo; Raffaele Nardone; Maria Luisa Zedde; Roberto Cantello; Francesco Brigo
Journal:  Clin Neurophysiol       Date:  2015-05-11       Impact factor: 3.708

5.  Optical coherence tomography reflects brain atrophy in multiple sclerosis: A four-year study.

Authors:  Shiv Saidha; Omar Al-Louzi; John N Ratchford; Pavan Bhargava; Jiwon Oh; Scott D Newsome; Jerry L Prince; Dzung Pham; Snehashis Roy; Peter van Zijl; Laura J Balcer; Elliot M Frohman; Daniel S Reich; Ciprian Crainiceanu; Peter A Calabresi
Journal:  Ann Neurol       Date:  2015-10-01       Impact factor: 10.422

6.  Non-invasive assessment of intracranial pressure using ocular sonography in neurocritical care patients.

Authors:  Thomas Geeraerts; Sybille Merceron; Dan Benhamou; Bernard Vigué; Jacques Duranteau
Journal:  Intensive Care Med       Date:  2008-05-29       Impact factor: 17.440

7.  Sub-clinical atrophy of the retinal nerve fibre layer in multiple sclerosis.

Authors:  Victoria Pueyo; Jose Ramon Ara; Carmen Almarcegui; Jesus Martin; Noemi Güerri; Elena García; Luis Emilio Pablo; Francisco Manuel Honrubia; Francisco Javier Fernandez
Journal:  Acta Ophthalmol       Date:  2010-11       Impact factor: 3.761

8.  Relationship of optic nerve and brain conventional and non-conventional MRI measures and retinal nerve fiber layer thickness, as assessed by OCT and GDx: a pilot study.

Authors:  Elliot M Frohman; Michael G Dwyer; Teresa Frohman; Jennifer L Cox; Amber Salter; Benjamin M Greenberg; Sara Hussein; Amy Conger; Peter Calabresi; Laura J Balcer; Robert Zivadinov
Journal:  J Neurol Sci       Date:  2009-05-12       Impact factor: 3.181

9.  Ultrasonographic investigation of optic neuritis.

Authors:  C Dees; R Buimer; A D Dick; H R Atta
Journal:  Eye (Lond)       Date:  1995       Impact factor: 3.775

10.  Comparison of accuracy of optic nerve ultrasound for the detection of intracranial hypertension in the setting of acutely fluctuating vs stable intracranial pressure: post-hoc analysis of data from a prospective, blinded single center study.

Authors:  Venkatakrishna Rajajee; Jeffrey James Fletcher; Lauryn Renee Rochlen; Teresa Lee Jacobs
Journal:  Crit Care       Date:  2012-05-11       Impact factor: 9.097

View more
  1 in total

Review 1.  Outcome measures assisting treatment optimization in multiple sclerosis.

Authors:  Gabriel Pardo; Samantha Coates; Darin T Okuda
Journal:  J Neurol       Date:  2021-08-02       Impact factor: 4.849

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.