Doppler Ultrasound Technology for Fetal Heart Rate Monitoring: A Review.

Paul Hamelmann, Rik Vullings, Alexander F Kolen, Jan W M Bergmans, Judith O E H van Laar, Piero Tortoli, Massimo Mischi.   

Abstract

Fetal well-being is commonly assessed by monitoring the fetal heart rate (fHR). In clinical practice, the de facto standard technology for fHR monitoring is based on the Doppler ultrasound (US). Continuous monitoring of the fHR before and during labor is performed using a US transducer fixed on the maternal abdomen. The continuous fHR monitoring, together with simultaneous monitoring of the uterine activity, is referred to as cardiotocography (CTG). In contrast, for intermittent measurements of the fHR, a handheld Doppler US transducer is typically used. In this article, the technology of Doppler US for continuous fHR monitoring and intermittent fHR measurements is described, with emphasis on fHR monitoring for CTG. Special attention is dedicated to the measurement environment, which includes the clinical setting in which fHR monitoring is commonly performed. In addition, to understand the signal content of acquired Doppler US signals, the anatomy and physiology of the fetal heart and the surrounding maternal abdomen are described. The challenges encountered in these measurements have led to different technological strategies, which are presented and critically discussed, with a focus on the US transducer geometry, Doppler signal processing, and fHR extraction methods.

Entities:  

Mesh:

Year:  2019        PMID: 31562079     DOI: 10.1109/TUFFC.2019.2943626

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  9 in total

1.  Correction for Hydrophone Spatial Averaging Artifacts for Circular Sources.

Authors:  Keith A Wear; Anant Shah; Christian Baker
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-11-24       Impact factor: 2.725

2.  Spatiotemporal Deconvolution of Hydrophone Response for Linear and Nonlinear Beams-Part II: Experimental Validation.

Authors:  Keith A Wear; Anant Shah; Christian Baker
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2022-03-30       Impact factor: 3.267

3.  New Method for Beat-to-Beat Fetal Heart Rate Measurement Using Doppler Ultrasound Signal.

Authors:  Tomasz Kupka; Adam Matonia; Michal Jezewski; Janusz Jezewski; Krzysztof Horoba; Janusz Wrobel; Robert Czabanski; Radek Martinek
Journal:  Sensors (Basel)       Date:  2020-07-22       Impact factor: 3.576

4.  Ultrasound Doppler fetal heart rate detection algorithm analyzes the correlation between twin selective fetal growth restriction and cord blood SFass fasL level.

Authors:  Qiaohong Cao; Cong Ma; Junbiao Zhu
Journal:  Pak J Med Sci       Date:  2021       Impact factor: 1.088

5.  Beyond research: improved perinatal care through scale-up of a Moyo fetal heart rate monitor coupled with simulation training in northern Tanzania for helping babies breathe.

Authors:  Yuda Munyaw; Joshua Gidabayda; Anita Yeconia; Godfrey Guga; Esto Mduma; Paschal Mdoe
Journal:  BMC Pediatr       Date:  2022-04-11       Impact factor: 2.125

6.  Frequency-Based Maternal Electrocardiogram Attenuation for Fetal Electrocardiogram Analysis.

Authors:  Pooneh Roshanitabrizi; Anita Krishnan; Catherine Ingbar; Tyler Salvador; Anqing Zhang; Mary T Donofrio; Rathinaswamy Govindan
Journal:  Ann Biomed Eng       Date:  2022-04-11       Impact factor: 4.219

7.  Investigation of Methods to Extract Fetal Electrocardiogram from the Mother's Abdominal Signal in Practical Scenarios.

Authors:  Sadaf Sarafan; Tai Le; Amir Mohammad Naderi; Quoc-Dinh Nguyen; Brandon Tiang-Yu Kuo; Tadesse Ghirmai; Huy-Dung Han; Michael P H Lau; Hung Cao
Journal:  Technologies (Basel)       Date:  2020-06-05

Review 8.  A review of fetal cardiac monitoring, with a focus on low- and middle-income countries.

Authors:  Camilo E Valderrama; Nasim Ketabi; Faezeh Marzbanrad; Peter Rohloff; Gari D Clifford
Journal:  Physiol Meas       Date:  2020-12-18       Impact factor: 2.688

9.  Noninvasive Dual-Modality Photoacoustic-Ultrasonic Imaging to Detect Mammalian Embryo Abnormalities after Prenatal Exposure to Methylmercury Chloride (MMC): A Mouse Study.

Authors:  Qi Qiu; Yali Huang; Bei Zhang; Doudou Huang; Xin Chen; Zhongxiong Fan; Jinpei Lin; Wensheng Yang; Kai Wang; Ning Qu; Juan Li; Zhihong Li; Jingyu Huang; Shenrui Li; Jiaxing Zhang; Gang Liu; Gang Rui; Xiaoyuan Chen; Qingliang Zhao
Journal:  Environ Health Perspect       Date:  2022-02-02       Impact factor: 9.031

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.