Morphologic changes induced by dilation of the pulmonary valve anulus with overlarge balloons in normal newborn lambs.

J C Ring, T J Kulik, B A Burke, J E Lock.   

Abstract

The optimal method for balloon dilation valvuloplasty of congenital pulmonary valve stenosis has not been established. The cardiac damage produced by using a balloon the same size as the pulmonary anulus has not been described. The use of balloons that are larger than the anulus or of a dynamic dilation technique may enhance gradient reduction, but their added risks are not known. The pulmonary valve anuli of 14 normal newborn lambs were dilated with angioplasty balloons 20% smaller to 90% larger than the anulus; in 3 dilations, a dynamic technique was used, consisting of withdrawal of the fully inflated balloon from the anulus into the body of the right ventricle. Twelve lambs were killed immediately after the procedure and 2 were killed later, and detailed gross anatomic and microscopic observations of the heart were made. These observations support the following conclusions: (1) Dilation of the pulmonary valve anulus with overlarge balloons is "clinically" well tolerated in normal newborn lambs. (2) The major damage to the heart from any balloon is not the pulmonary anulus, but to the right ventricular outflow tract and free wall, with mural hemorrhages of varying size. (3) Trauma is minor if the balloon is 30% larger than the anulus, but is considerable when the balloon is 50% larger; (4) Trauma is worst subjacent to the proximal end of the balloon, so that longer balloons may cause greater damage; and (5) Resolution of acute right ventricular hemorrhage occurs with small, patchy areas of fibrosis.

Entities:  

Mesh:

Year:  1985        PMID: 3155589     DOI: 10.1016/0002-9149(85)90330-3

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  17 in total

1.  Effects of nifedipine and diltiazem on pharmacokinetics of cefpodoxime following its oral administration.

Authors:  A Deslandes; F Camus; C Lacroix; C Carbon; R Farinotti
Journal:  Antimicrob Agents Chemother       Date:  1996-12       Impact factor: 5.191

2.  Anatomic features of congenital pulmonary valvar stenosis.

Authors:  B M Gikonyo; R V Lucas; J E Edwards
Journal:  Pediatr Cardiol       Date:  1987       Impact factor: 1.655

3.  Operative balloon dilatation for pulmonary atresia with intact ventricular septum.

Authors:  J R Hamilton; S F Fonseka; N Wilson; D F Dickinson; D R Walker
Journal:  Br Heart J       Date:  1987-10

4.  Balloon dilatation of stenotic lesions of the heart.

Authors:  S Shrivastava
Journal:  Indian J Pediatr       Date:  1988 Jan-Feb       Impact factor: 1.967

5.  Operative findings after percutaneous pulmonary balloon dilatation of the right ventricular outflow tract in tetralogy of Fallot.

Authors:  S A Battistessa; A Robles; M Jackson; S Miyamoto; R Arnold; R McKay
Journal:  Br Heart J       Date:  1990-11

6.  Long-term pulmonary regurgitation following balloon valvuloplasty for pulmonary stenosis risk factors and relationship to exercise capacity and ventricular volume and function.

Authors:  David M Harrild; Andrew J Powell; Trang X Tran; Trang X Trang; Tal Geva; James E Lock; Jonathan Rhodes; Doff B McElhinney
Journal:  J Am Coll Cardiol       Date:  2010-03-09       Impact factor: 24.094

7.  Longitudinal function and ventricular dyssynchrony are restored in children with pulmonary stenosis after percutaneous balloon pulmonary valvuloplasty.

Authors:  Ragab A Mahfouz; Tamer M Moustafa; Mohammad Gouda; Marwa Gad
Journal:  Int J Cardiovasc Imaging       Date:  2016-12-10       Impact factor: 2.357

8.  Balloon dilatation of the pulmonary valve in the first year of life in patients with tetralogy of Fallot: a preliminary study.

Authors:  S A Qureshi; C R Kirk; R K Lamb; R Arnold; J L Wilkinson
Journal:  Br Heart J       Date:  1988-09

9.  The morphology of the right ventricular outflow tract after percutaneous pulmonary valvotomy: long term follow up.

Authors:  M Robertson; L N Benson; J S Smallhorn; N Musewe; R M Freedom; C A Moes; P Burrows; A E Johnston; F A Burrows; R D Rowe
Journal:  Br Heart J       Date:  1987-09

10.  Percutaneous balloon valvuloplasty for pulmonary valve stenosis in infants and children.

Authors:  I D Sullivan; P J Robinson; F J Macartney; J F Taylor; P G Rees; C Bull; J E Deanfield
Journal:  Br Heart J       Date:  1985-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.