Mitsuhiro Kimura1, Hidetake Yabuuchi2, Ryoji Matsumoto3, Koji Kobayashi3, Yasuo Yamashita3, Kazuya Nagatomo1, Ryoji Mikayama1, Takeshi Kamitani4, Koji Sagiyama4, Yuzo Yamasaki4. 1. Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan. 2. Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan. h-yabu@med.kyushu-u.ac.jp. 3. Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan. 4. Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
Abstract
OBJECTIVES: It is necessary to standardize the examination procedure and diagnostic criteria of diffusion tensor imaging (DTI). Thus, the purpose of this study was to examine the reproducibility of measurements using a standardization phantom composed of different fibre materials with different fibre densities (FDs) for the evaluation of fractional anisotropy (FA) derived from DTI. MATERIALS AND METHODS: Two types of fibre materials wrapped in heat-shrinkable tubes were used as fibre phantoms. We designed fibre phantoms with three different FDs of each fibre material. The standardization phantom was examined using DTI protocol six times a day, and each examination session was repeated once a month for 7 consecutive months. Fibre tracking was performed by setting regions of interest in the FA map, and FA was measured in each fibre phantom. Coefficients of variation (CVs) were used to evaluate the inter-examination reproducibility of FA values. Furthermore, Bland-Altman plots were used to evaluate the intra-operator reproducibility of FA measurements. RESULTS: All CVs for each fibre phantom were within 2% throughout the 7-month study of repeated DTI sessions. The high intra-operator reproducibility of the FA measurement was confirmed. DISCUSSION: High reproducibility of measurements using a standardization phantom for the evaluation of FA was achieved.
OBJECTIVES: It is necessary to standardize the examination procedure and diagnostic criteria of diffusion tensor imaging (DTI). Thus, the purpose of this study was to examine the reproducibility of measurements using a standardization phantom composed of different fibre materials with different fibre densities (FDs) for the evaluation of fractional anisotropy (FA) derived from DTI. MATERIALS AND METHODS: Two types of fibre materials wrapped in heat-shrinkable tubes were used as fibre phantoms. We designed fibre phantoms with three different FDs of each fibre material. The standardization phantom was examined using DTI protocol six times a day, and each examination session was repeated once a month for 7 consecutive months. Fibre tracking was performed by setting regions of interest in the FA map, and FA was measured in each fibre phantom. Coefficients of variation (CVs) were used to evaluate the inter-examination reproducibility of FA values. Furthermore, Bland-Altman plots were used to evaluate the intra-operator reproducibility of FA measurements. RESULTS: All CVs for each fibre phantom were within 2% throughout the 7-month study of repeated DTI sessions. The high intra-operator reproducibility of the FA measurement was confirmed. DISCUSSION: High reproducibility of measurements using a standardization phantom for the evaluation of FA was achieved.
Authors: Qian Dong; Robert C Welsh; Thomas L Chenevert; Ruth C Carlos; Pia Maly-Sundgren; Diana M Gomez-Hassan; Suresh K Mukherji Journal: J Magn Reson Imaging Date: 2004-01 Impact factor: 4.813
Authors: Ezequiel Farrher; Joachim Kaffanke; A Avdo Celik; Tony Stöcker; Farida Grinberg; N Jon Shah Journal: Magn Reson Imaging Date: 2012-01-27 Impact factor: 2.546
Authors: Els Fieremans; Yves De Deene; Steven Delputte; Mahir S Ozdemir; Yves D'Asseler; Jelle Vlassenbroeck; Karel Deblaere; Eric Achten; Ignace Lemahieu Journal: J Magn Reson Date: 2007-11-01 Impact factor: 2.229
Authors: P S Tofts; D Lloyd; C A Clark; G J Barker; G J Parker; P McConville; C Baldock; J M Pope Journal: Magn Reson Med Date: 2000-03 Impact factor: 4.668
Authors: Ryckie G Wade; Steven F Tanner; Irvin Teh; John P Ridgway; David Shelley; Brian Chaka; James J Rankine; Gustav Andersson; Mikael Wiberg; Grainne Bourke Journal: Front Surg Date: 2020-04-16
Authors: Timothy T Griffiths; Robert Flather; Irvin Teh; Hamied A Haroon; David Shelley; Sven Plein; Grainne Bourke; Ryckie G Wade Journal: Sci Rep Date: 2021-07-22 Impact factor: 4.379