Literature DB >> 31546201

Microfluidic smartphone quantitation of Escherichia coli in synthetic urine.

Isabel P Alves1, Nuno M Reis2.   

Abstract

In spite of the clinical need, there is a major gap in rapid diagnostics for identification and quantitation of E. coli and other pathogens, also regarded as the biggest bottleneck in the fight against the spread of antimicrobial resistant bacterial strains. This study reports for the first time an optical, smartphone-based microfluidic fluorescence sandwich immunoassay capable of quantifying E. coli in buffer and synthetic urine in less than 25 min without sample preparation nor concentration. A limit of detection (LoD) up to 240 CFU/mL, comensurate with cut-off for UTIs (103-105 CFUs/mL) was achieved. Replicas of full response curves performed with 100-107 CFUs/mL of E. coli K12 in synthetic urine yielded recovery values in the range 80-120%, assay reproducibility below 30% and precision below 20%, therefore similar to high-performance automated immunoassays. The unrivalled LoD was mainly linked to the 'open fluidics' nature of the 10-bore microfluidic strips used that enabled passing a large volume of sample through the microcapillaries coated with capture antibody. The new smartphone based test has the potential of being as a rapid, point-of-care test for rule-in of E. coli infections that are responsible for around 80% of UTIs, helping to stop the over-prescription of antibiotics and the monitoring of patients with other symptomatic communicable diseases caused by E. coli at global scale.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  E. coli detection; Microcapillary Film; Point-of-care diagnostics; Smartphone readout; Synthetic urine; UTIs

Mesh:

Year:  2019        PMID: 31546201     DOI: 10.1016/j.bios.2019.111624

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  5 in total

Review 1.  Advances in Optical Detection of Human-Associated Pathogenic Bacteria.

Authors:  Andrea Locke; Sean Fitzgerald; Anita Mahadevan-Jansen
Journal:  Molecules       Date:  2020-11-11       Impact factor: 4.411

2.  Gravity-Driven Microfluidic Siphons: Fluidic Characterization and Application to Quantitative Immunoassays.

Authors:  Nuno M Reis; Sarah H Needs; Sophie M Jegouic; Kirandeep K Gill; Sirintra Sirivisoot; Scott Howard; Jack Kempe; Shaan Bola; Kareem Al-Hakeem; Ian M Jones; Tanapan Prommool; Prasit Luangaram; Panisadee Avirutnan; Chunya Puttikhunt; Alexander D Edwards
Journal:  ACS Sens       Date:  2021-12-02       Impact factor: 7.711

3.  Smartphone multiplex microcapillary diagnostics using Cygnus: Development and evaluation of rapid serotype-specific NS1 detection with dengue patient samples.

Authors:  Sarah Helen Needs; Sirintra Sirivisoot; Sophie Jegouic; Tanapan Prommool; Prasit Luangaram; Chatchawan Srisawat; Kanokwan Sriraksa; Wannee Limpitikul; Dumrong Mairiang; Prida Malasit; Panisadee Avirutnan; Chunya Puttikhunt; Alexander Daniel Edwards
Journal:  PLoS Negl Trop Dis       Date:  2022-04-07

Review 4.  Healthy, safe and responsible: the modern female traveller.

Authors:  Irmgard L Bauer
Journal:  Trop Dis Travel Med Vaccines       Date:  2021-06-05

Review 5.  Flow Chemistry in Contemporary Chemical Sciences: A Real Variety of Its Applications.

Authors:  Marek Trojanowicz
Journal:  Molecules       Date:  2020-03-21       Impact factor: 4.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.