Literature DB >> 31542569

Carbon-fibre-reinforced PEEK: An alternative material for flexion bushings of rotating hinged knee joints?

Stefan Schroeder1, Steffen Braun2, Ulrike Mueller3, Matthias Vogel4, Robert Sonntag5, Sebastian Jaeger6, Jan Philippe Kretzer7.   

Abstract

BACKGROUND: For prosthetic knee joints of the hinged type, typically polyethylene (PE) flexion bushings are used between axis and femoral component to prevent metallic wear. Nevertheless, PE-wear can lead to periprosthetic osteolysis followed by aseptic loosening of the implant. Based on high creep and wear resistance carbon-fibre-reinforced polyether ether ketones (CFR-PEEKs) could provide an alternative material to ultra-high-molecular-weight polyethylene (UHMWPE) for this bearing type.
METHODS: Flexion bushings of four different materials were investigated (CFR-PEEK pitch fibres, CFR-PEEK PAN fibres, virgin PEEK without carbon fibres and UHMWPE) using a bushing tester. For determination of the polymeric and metallic wear, gravimetric measurements and particle analyses were performed.
RESULTS: The polymeric wear rates of CFR-PEEK PAN (6.657 ± 0.714 mg/106 cycles) and CFR-PEEK pitch (32.085 ± 2.748 mg/106 cycles) were significantly higher compared to the polymeric wear rates of virgin PEEK (0.764 ± 0.283 mg/106 cycles) or UHMWPE (-0.015 ± 0.011 mg/106 cycles) (p < .001). In addition, the metallic wear rates were significantly higher when using bushings made of CFR-PEEK PAN (3.373 ± 0.214 mg/106 cycles) and CFR-PEEK pitch (3.604 ± 0.355 mg/106 cycles), than when using bushings made of virgin PEEK (0.177 ± 0.049 mg/106 cycles) or UHMWPE (0.031 ± 0.011 mg/106 cycles) (p < .001). The mean particle size of the two CFR-PEEK groups was significantly smaller compared to the virgin PEEK and UHMWPE group (p < .001).
CONCLUSION: According to these results, the clinical use of CFR-PEEK in combination with CoCr could lead to higher wear rates and this should be avoided. Virgin PEEK may still be considered as an alternative to UHMWPE to use it for flexion bushings in a hinged knee joint.
Copyright © 2019 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Bushings; CFR-PEEK; CoCr; Rotating hinged knee; Wear

Mesh:

Substances:

Year:  2019        PMID: 31542569     DOI: 10.1016/j.jmbbm.2019.103434

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  1 in total

1.  Bioinspired nacre-like PEEK material with superior tensile strength and impact toughness.

Authors:  Shu Zhu; Tianwen Yan; Xinlin Huang; Elwathig A M Hassan; Jianfeng Zhou; Sen Zhang; Mengyun Xiong; Muhuo Yu; Zhaomin Li
Journal:  RSC Adv       Date:  2022-05-23       Impact factor: 4.036

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.