Literature DB >> 31542547

Reverse electrodialysis (RED) using a bipolar membrane to suppress inorganic fouling around the cathode.

Ji-Hyung Han1, Namjo Jeong2, Chan-Soo Kim2, Kyo Sik Hwang2, Hanki Kim2, Joo-Youn Nam2, Eunjin Jwa2, SeungCheol Yang3, Jiyeon Choi2.   

Abstract

When operating reverse electrodialysis (RED) with several hundreds of cell pairs, a large stack voltage of more than 10 V facilitates water electrolysis, even when redox couples are employed for the electrode reaction. Upon feeding natural water containing multivalent ions, ion crossover through a shielding membrane causes inorganic scaling around the cathode and the interior of the membrane stack, due to the combination with the hydroxide ions produced via water reduction. In this work, we introduce a bipolar membrane (BPM) as a shielding membrane at the cathode to suppress inorganic precipitation. Water splitting in the bilayer structure of the BPM can block the ions diffusing from the catholyte and the feed solution, maintaining the current density. To evaluate the effect of the BPM on the inorganic precipitates, diluted sea salt solution is allowed to flow through the outermost feed channel near the cathode, in order to maintain as large a stack voltage as possible, which is important to induce water splitting in the BPM when incorporated into an RED stack of 100 cell pairs. We measure the electric power of the RED according to the arrangement of the BPM and compare it with that of conventional RED. The degree of inorganic scaling is also compared according to the kind of shielding membrane used (anion exchange membrane, cation exchange membrane, and BPM (Neosepta or Fumasep)). The BPM (Neosepta) shows the best performance for suppressing the formation of precipitates. It can hence be used to design a highly stable electrode system for long-term operation of a large-scale RED feeding natural water.
Copyright © 2019 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Bipolar membrane; Inorganic fouling; Reverse electrodialysis; Water electrolysis; Water splitting

Mesh:

Substances:

Year:  2019        PMID: 31542547     DOI: 10.1016/j.watres.2019.115078

Source DB:  PubMed          Journal:  Water Res        ISSN: 0043-1354            Impact factor:   11.236


  2 in total

Review 1.  Fouling Prevention in Polymeric Membranes by Radiation Induced Graft Copolymerization.

Authors:  Muhammad Nidzhom Zainol Abidin; Mohamed Mahmoud Nasef; Takeshi Matsuura
Journal:  Polymers (Basel)       Date:  2022-01-04       Impact factor: 4.329

Review 2.  Selectivity of Transport Processes in Ion-Exchange Membranes: Relationship with the Structure and Methods for Its Improvement.

Authors:  Irina Stenina; Daniel Golubenko; Victor Nikonenko; Andrey Yaroslavtsev
Journal:  Int J Mol Sci       Date:  2020-08-01       Impact factor: 5.923

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.