Literature DB >> 31536645

Defect morphology, bone thickness, exposure settings and examiner experience affect the diagnostic accuracy of standardized digital periapical radiographic images but not of cone beam computed tomography in the detection of peri-implant osseous defects: An in vitro study.

George Pelekos1, Judy M N Tse1, Dominic Ho1, Maurizio S Tonetti1.   

Abstract

AIMS: To investigate the effect of defect morphology, bone thickness and examiner experience on the accuracy to detect the presence, the type and the depth of peri-implant defects with digital periapical radiographs (PAs) and cone beam computed tomography (CBCT) in an in vitro model.
METHODS: Thirty six implants were placed in fresh porcine rib bone with different types of standardized defects while sites with no defect served as control. Fourteen masked examiners evaluated 324 PAs and 108 CBCT images. The presence and type of defect, the location of the bottom of the defect and the location of first bone-to-implant contact were recorded. The sensitivity, specificity, accuracy, positive and negative predictive values were calculated for each type of defect using actual measurements as the gold standard.
RESULTS: The diagnostic accuracy for PAs was affected by defect morphology, exposure time, thickness of bone walls and the level of experience of the examiner. The overall diagnostic accuracy of CBCT was high (>96%) for all types of defects.
CONCLUSION: Cone beam computed tomography showed better diagnostic accuracy in the detection of peri-implant defects, this can be attributed to the fact that CBCT seems to be less affected by variables that contribute to the poorer performance of PAs.
© 2019 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  cone beam computed tomography; diagnostic accuracy; peri-implant defect; peri-implantitis/diagnosis; periapical radiograph

Year:  2019        PMID: 31536645     DOI: 10.1111/jcpe.13200

Source DB:  PubMed          Journal:  J Clin Periodontol        ISSN: 0303-6979            Impact factor:   8.728


  4 in total

1.  Does dose optimisation in digital panoramic radiography affect diagnostic performance?

Authors:  Luciano Augusto Cano Martins; Danieli M Brasil; Laís A Forner; Cassiana Viccari; Francisco Haiter-Neto; Deborah Q Freitas; Matheus L Oliveira
Journal:  Clin Oral Investig       Date:  2020-08-26       Impact factor: 3.573

2.  The influence of initial defect morphology of alveolar ridge on volumetric change of grafted bone following guided bone regeneration in the anterior maxilla region: an exploratory retrospective study.

Authors:  Yuan Li; Xiao-Meng Zhang; Shu-Jiao Qian; Shi-Chong Qiao; Hong-Chang Lai; Jun-Yu Shi
Journal:  Ann Transl Med       Date:  2020-12

Review 3.  Diagnostic accuracy of imaging examinations for peri-implant bone defects around titanium and zirconium dioxide implants: A systematic review and meta-analysis.

Authors:  Mariana Murai Chagas; Solange Kobayashi-Velasco; Thais Gimenez; Marcelo Gusmão Paraiso Cavalcanti
Journal:  Imaging Sci Dent       Date:  2021-11-18

4.  Intra- and inter-observer agreements in detecting peri-implant bone defects between periapical radiography and cone beam computed tomography: A clinical study.

Authors:  Chu-Nan Zhang; Yu Zhu; Lin-Feng Fan; Xiao Zhang; Yin-Hua Jiang; Ying-Xin Gu
Journal:  J Dent Sci       Date:  2020-11-14       Impact factor: 2.080

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.