Francesco Zuffetti1, Luca Testarelli2, Pio Bertani3, Spyridon Vassilopoulos4, Tiziano Testori5, Renzo Guarnieri6. 1. Assistant Professor, Section of Implant Dentistry and Oral Rehabilitation, IRCCS Galeazzi Institute, and Private Practice, Milan, Italy. 2. Associate Professor, Department of Oral and Maxillofacial Sciences, La Sapienza University, and Private Practice, Rome, Italy. 3. Private Practice, Parma, Italy. 4. Assistant Professor, Department of Periodontology, National and Kapodistrian University of Athens, and Private Practice, Athens, Greece. 5. Head of Section of Implantology and Oral Rehabilitation, Department of Odontology, IRCCS Galeazzi, University of Milan, Milan, Italy; Adjunct Clinical Associate Professor, Department of Periodontics and Oral Medicine, School of Dentistry, University of Michigan, Ann Arbor, MI; and Private Practice, Como, Italy. 6. Adjunct Professor, Department of Oral and Maxillofacial Sciences, La Sapienza University, Rome, and Private Practice, Treviso, Italy. Electronic address: renzoguarnieri@gmail.com.
Abstract
PURPOSE: We aimed to retrospectively evaluate the radiographic and clinical results and the success rate of short implants with a laser-microgrooved collar (≤7.5 mm) placed in the posterior areas after up to 3 to 5 years of function and the possible influence of several variables-such as gender, periodontitis, smoking habit, location, implant stability at placement, and prosthetic fixation design-on implant marginal bone loss (MBL). MATERIALS AND METHODS: A chart review was used for this multicenter study, which involved 5 private dental clinics. All patients had been treated with short dental implants with a laser-microgrooved collar from January 2012 to December 2015. RESULTS: A total of 174 patients (99 male and 75 female patients; mean age, 51.6 ± 2.8 years) with 254 implants were evaluated. Seven short implants failed. The cumulative success rate was 97.2%, without a statistically significant difference between implants placed in the posterior maxilla and mandible. The mean MBL was 0.18 ± 0.7 mm at the mesial aspect and 0.19 ± 0.6 mm at the distal aspect. No statistical relationships were found between MBL and gender, periodontitis, smoking habit, location, implant stability at placement, and prosthetic fixation design. CONCLUSIONS: At the end of the 3- to 5-year follow-up period, short implants with a laser-microgrooved collar (≤7.5 mm) in the posterior areas yielded a relatively high cumulative success rate. The laser-microgrooved collar implant maintained stable marginal bone levels. No investigated variable was statistically associated with MBL.
PURPOSE: We aimed to retrospectively evaluate the radiographic and clinical results and the success rate of short implants with a laser-microgrooved collar (≤7.5 mm) placed in the posterior areas after up to 3 to 5 years of function and the possible influence of several variables-such as gender, periodontitis, smoking habit, location, implant stability at placement, and prosthetic fixation design-on implant marginal bone loss (MBL). MATERIALS AND METHODS: A chart review was used for this multicenter study, which involved 5 private dental clinics. All patients had been treated with short dental implants with a laser-microgrooved collar from January 2012 to December 2015. RESULTS: A total of 174 patients (99 male and 75 female patients; mean age, 51.6 ± 2.8 years) with 254 implants were evaluated. Seven short implants failed. The cumulative success rate was 97.2%, without a statistically significant difference between implants placed in the posterior maxilla and mandible. The mean MBL was 0.18 ± 0.7 mm at the mesial aspect and 0.19 ± 0.6 mm at the distal aspect. No statistical relationships were found between MBL and gender, periodontitis, smoking habit, location, implant stability at placement, and prosthetic fixation design. CONCLUSIONS: At the end of the 3- to 5-year follow-up period, short implants with a laser-microgrooved collar (≤7.5 mm) in the posterior areas yielded a relatively high cumulative success rate. The laser-microgrooved collar implant maintained stable marginal bone levels. No investigated variable was statistically associated with MBL.