Literature DB >> 31516398

Dosimetric impact of uncorrected systematic yaw rotation in VMAT for peripheral lung SABR.

Sarah Barrett1, Pierre Thirion2, Dean Harper2, Andrew J Simpkin3, Michelle Leech1, Kim Hickey2, Laoise Ryan2, Laure Marignol1.   

Abstract

AIM: This study aimed to evaluate the dosimetric impact of uncorrected yaw rotational error on both target coverage and OAR dose metrics in this patient population.
BACKGROUND: Rotational set up errors can be difficult to correct in lung VMAT SABR treatments, and may lead to a change in planned dose distributions.
MATERIALS AND METHODS: We retrospectively applied systematic yaw rotational errors in 1° degree increments up to -5° and +5° degrees in 16 VMAT SABR plans. The impact on PTV and OARs (oesophagus, spinal canal, heart, airway, chest wall, brachial plexus, lung) was evaluated using a variety of dose metrics. Changes were assessed in relation to percentage deviation from approved planned dose at 0 degrees.
RESULTS: Target coverage was largely unaffected with the largest mean and maximum percentage difference being 1.4% and 6% respectively to PTV D98% at +5 degrees yaw.Impact on OARs was varied. Minimal impact was observed in oesophagus, spinal canal, chest wall or lung dose metrics. Larger variations were observed in the heart, airway and brachial plexus. The largest mean and maximum percentage differences being 20.77% and 311% respectively at -5 degrees yaw to airway D0.1cc, however, the clinical impact was negligible as these variations were observed in metrics with minimal initial doses.
CONCLUSIONS: No clinically unacceptable changes to dose metrics were observed in this patient cohort but large percentage deviations from approved dose metrics in OARs were noted. OARs with associated PRV structures appear more robust to uncorrected rotational error.

Entities:  

Keywords:  Lung SABR; Rotational error; Setup error; VMAT

Year:  2019        PMID: 31516398      PMCID: PMC6731354          DOI: 10.1016/j.rpor.2019.07.010

Source DB:  PubMed          Journal:  Rep Pract Oncol Radiother        ISSN: 1507-1367


  29 in total

1.  Stereotactic body radiation therapy for inoperable early stage lung cancer.

Authors:  Robert Timmerman; Rebecca Paulus; James Galvin; Jeffrey Michalski; William Straube; Jeffrey Bradley; Achilles Fakiris; Andrea Bezjak; Gregory Videtic; David Johnstone; Jack Fowler; Elizabeth Gore; Hak Choy
Journal:  JAMA       Date:  2010-03-17       Impact factor: 56.272

2.  Critical appraisal of Acuros XB and Anisotropic Analytic Algorithm dose calculation in advanced non-small-cell lung cancer treatments.

Authors:  Antonella Fogliata; Giorgia Nicolini; Alessandro Clivio; Eugenio Vanetti; Luca Cozzi
Journal:  Int J Radiat Oncol Biol Phys       Date:  2012-01-31       Impact factor: 7.038

3.  Evaluation of rotational errors in treatment setup of stereotactic body radiation therapy of liver cancer.

Authors:  Minsong Cao; Foster D Lasley; Indra J Das; Colleen M Desrosiers; Eric D Slessinger; Higinia R Cardenes
Journal:  Int J Radiat Oncol Biol Phys       Date:  2012-06-23       Impact factor: 7.038

4.  Stereotactic radiotherapy for peripheral lung tumors: a comparison of volumetric modulated arc therapy with 3 other delivery techniques.

Authors:  Chin Loon Ong; Wilko F A R Verbakel; Johan P Cuijpers; Ben J Slotman; Frank J Lagerwaard; Suresh Senan
Journal:  Radiother Oncol       Date:  2010-11-11       Impact factor: 6.280

5.  Translational and rotational intra- and inter-fractional errors in patient and target position during a short course of frameless stereotactic body radiotherapy.

Authors:  Mirjana Josipovic; Gitte Fredberg Persson; Ashildur Logadottir; Bob Smulders; Gunnar Westmann; Jens Peter Bangsgaard
Journal:  Acta Oncol       Date:  2012-01-23       Impact factor: 4.089

6.  Dosimetric effects of rotational offsets in stereotactic body radiation therapy (SBRT) for lung cancer.

Authors:  Yun Yang; Suzanne Catalano; Chris R Kelsey; David S Yoo; Fang-Fang Yin; Jing Cai
Journal:  Med Dosim       Date:  2014       Impact factor: 1.482

7.  The dosimetric impact of prostate rotations during electromagnetically guided external-beam radiation therapy.

Authors:  Hanan Amro; Daniel A Hamstra; Daniel L Mcshan; Howard Sandler; Karen Vineberg; Scott Hadley; Dale Litzenberg
Journal:  Int J Radiat Oncol Biol Phys       Date:  2012-05-02       Impact factor: 7.038

8.  Assessment of the robustness of volumetric-modulated arc therapy for lung radiotherapy.

Authors:  K Edmunds; J Bedford
Journal:  Br J Radiol       Date:  2013-02-07       Impact factor: 3.039

Review 9.  Stereotactic body radiation therapy in the re-irradiation situation--a review.

Authors:  Frederick Mantel; Michael Flentje; Matthias Guckenberger
Journal:  Radiat Oncol       Date:  2013-01-05       Impact factor: 3.481

10.  Recommendations for implementing stereotactic radiotherapy in peripheral stage IA non-small cell lung cancer: report from the Quality Assurance Working Party of the randomised phase III ROSEL study.

Authors:  Coen W Hurkmans; Johan P Cuijpers; Frank J Lagerwaard; Joachim Widder; Uulke A van der Heide; Danny Schuring; Suresh Senan
Journal:  Radiat Oncol       Date:  2009-01-12       Impact factor: 3.481

View more
  1 in total

1.  Software simulation of tumour motion dose effects during flattened and unflattened ITV-based VMAT lung SBRT.

Authors:  Marta Adamczyk; Marta Kruszyna-Mochalska; Anna Rucińska; Tomasz Piotrowski
Journal:  Rep Pract Oncol Radiother       Date:  2020-06-11
  1 in total