Literature DB >> 24485056

Dosimetric effects of rotational offsets in stereotactic body radiation therapy (SBRT) for lung cancer.

Yun Yang1, Suzanne Catalano1, Chris R Kelsey1, David S Yoo1, Fang-Fang Yin1, Jing Cai2.   

Abstract

To quantitatively evaluate dosimetric effects of rotational offsets in stereotactic body radiation therapy (SBRT) for lung cancer. Overall, 11 lung SBRT patients (8 female and 3 male; mean age: 75.0 years) with medially located tumors were included. Treatment plans with simulated rotational offsets of 1°, 3°, and 5° in roll, yaw, and pitch were generated and compared with the original plans. Both clockwise and counterclockwise rotations were investigated. The following dosimetric metrics were quantitatively evaluated: planning target volume coverage (PTV V100%), max PTV dose (PTV Dmax), percentage prescription dose to 0.35cc of cord (cord D0.35cc), percentage prescription dose to 0.35cc and 5cc of esophagus (esophagus D0.35cc and D5cc), and volume of the lungs receiving at least 20Gy (lung V20). Statistical significance was tested using Wilcoxon signed rank test at the significance level of 0.05. Overall, small differences were found in all dosimetric matrices at all rotational offsets: 95.6% of differences were < 1% or < 1Gy. Of all rotational offsets, largest change in PTV V100%, PTV Dmax, cord D0.35cc, esophagus D0.35cc, esophagus D5cc, and lung V20 was - 8.36%, - 6.06%, 11.96%, 8.66%, 6.02%, and - 0.69%, respectively. No significant correlation was found between any dosimetric change and tumor-to-cord/esophagus distances (R(2) range: 0 to 0.44). Larger dosimetric changes and intersubject variations were observed at larger rotational offsets. Small dosimetric differences were found owing to rotational offsets up to 5° in lung SBRT for medially located tumors. Larger intersubject variations were observed at larger rotational offsets.
© 2014 American Association of Medical Dosimetrists Published by American Association of Medical Dosimetrists All rights reserved.

Entities:  

Keywords:  6D correction; IGRT; Lung SBRT; Rotation

Mesh:

Year:  2014        PMID: 24485056     DOI: 10.1016/j.meddos.2013.11.002

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  4 in total

1.  Dosimetric effects of roll rotational setup errors on lung stereotactic ablative radiotherapy using volumetric modulated arc therapy.

Authors:  Jaegi Lee; Jung-In Kim; Sung-Joon Ye; Hak Jae Kim; Joel Carlson; Jong Min Park
Journal:  Br J Radiol       Date:  2015-09-15       Impact factor: 3.039

2.  Dosimetric impact of uncorrected systematic yaw rotation in VMAT for peripheral lung SABR.

Authors:  Sarah Barrett; Pierre Thirion; Dean Harper; Andrew J Simpkin; Michelle Leech; Kim Hickey; Laoise Ryan; Laure Marignol
Journal:  Rep Pract Oncol Radiother       Date:  2019-09-04

3.  Clinical Study of Orthogonal-View Phase-Matched Digital Tomosynthesis for Lung Tumor Localization.

Authors:  You Zhang; Lei Ren; Irina Vergalasova; Fang-Fang Yin
Journal:  Technol Cancer Res Treat       Date:  2017-04-28

4.  Using previously registered cone beam computerized tomography images to facilitate online computerized tomography to cone beam computerized tomography image registration in lung stereotactic body radiation therapy.

Authors:  Jian Liang; Qiang Liu; Inga Grills; Thomas Guerrero; Craig Stevens; Di Yan
Journal:  J Appl Clin Med Phys       Date:  2022-02-02       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.