Xuge Fan1, Fredrik Forsberg2, Anderson D Smith3, Stephan Schröder1, Stefan Wagner4, Mikael Östling3, Max C Lemme4,3, Frank Niklaus1. 1. Department of Micro and Nanosystems, School of Electrical Engineering and Computer Science , KTH Royal Institute of Technology , SE-10044 Stockholm , Sweden. 2. Scania Tekniskt Centrum , 15148 Södertälje , Sweden. 3. Department of Integrated Devices and Circuits, School of Electrical Engineering and Computer Science , KTH Royal Institute of Technology , SE-164 40 Kista , Sweden. 4. Faculty of Electrical Engineering and Information Technology , RWTH Aachen University , Otto-Blumenthal-Strsse 25 , 52074 Aachen , Germany.
Abstract
Graphene is an atomically thin material that features unique electrical and mechanical properties, which makes it an extremely promising material for future nanoelectromechanical systems (NEMS). Recently, basic NEMS accelerometer functionality has been demonstrated by utilizing piezoresistive graphene ribbons with suspended silicon proof masses. However, the proposed graphene ribbons have limitations regarding mechanical robustness, manufacturing yield, and the maximum measurement current that can be applied across the ribbons. Here, we report on suspended graphene membranes that are fully clamped at their circumference and have attached silicon proof masses. We demonstrate their utility as piezoresistive NEMS accelerometers, and they are found to be more robust, have longer life span and higher manufacturing yield, can withstand higher measurement currents, and are able to suspend larger silicon proof masses, as compared to the previous graphene ribbon devices. These findings are an important step toward bringing ultraminiaturized piezoresistive graphene NEMS closer toward deployment in emerging applications such as in wearable electronics, biomedical implants, and internet of things (IoT) devices.
Graphene is an atomically thin material that features unique electrical and mechanical properties, which makes it an extremely promising material for future nanoelectromechanical systems (NEMS). Recently, basic NEMS accelerometer functionality has been demonstrated by utilizing piezoresistive graphene ribbons with suspended silicon proof masses. However, the proposed graphene ribbons have limitations regarding mechanical robustness, manufacturing yield, and the maximum measurement current that can be applied across the ribbons. Here, we report on suspended graphene membranes that are fully clamped at their circumference and have attached silicon proof masses. We demonstrate their utility as piezoresistive NEMS accelerometers, and they are found to be more robust, have longer life span and higher manufacturing yield, can withstand higher measurement currents, and are able to suspend larger silicon proof masses, as compared to the previous graphene ribbon devices. These findings are an important step toward bringing ultraminiaturized piezoresistive graphene NEMS closer toward deployment in emerging applications such as in wearable electronics, biomedical implants, and internet of things (IoT) devices.
The monitoring
of acceleration
is essential in a broad range of applications such as navigation systems,
automotive crash detection systems, and structural monitoring. Typical
microelectromechanical system (MEMS) accelerometers occupy die areas
of the order of several square millimeters. Further miniaturization
of MEMS accelerometers results in smaller components and packages
and ultimately in reduced costs, which is critical for emerging applications
such as wearable electronics,[1] biomedical
implants,[2] nanoscale robotics,[3] and the internet of things (IoT).[4] However, downscaling of MEMS accelerometers comprises miniaturization
of the electromechanical transducer and the size of the proof mass,
thereby severely reducing device sensitivity.Graphene, as a
two-dimensional material, is atomically thin and
features high carrier mobility,[5] high mechanical
strength,[6,7] and piezoresistive electromechanical transduction.[8,9] At the same time, graphene technology is maturing and generally
compatible with silicon semiconductor fabrication lines.[10] Therefore, graphene is an extremely interesting
functional material for ultrasmall nanoelectromechanical system (NEMS)
devices.[8,11−15] Suspended atomically thin graphene structures that
include doubly clamped graphene beams, fully clamped graphene membranes
and graphene cantilevers have been extensively studied and have been
utilized in electromechanical resonators,[16−20] various types of pressure sensors,[9,21−28] strain sensors,[29,30] high responsivity photodetectors,[31] NEMS switches,[32] earphones,[33] loudspeakers,[34] microphones,[35,36] and other NEMS devices.[7,37−42] NEMS accelerometers and gyroscopes typically require masses that
are attached to suspended membranes, beams, or cantilevers. However,
realizing suspended graphene with large attached proof masses remains
challenging. Although there are reports of atomically thin graphene
membranes with attached masses,[43−45] these masses are limited to extremely
small and thin deposited coatings.Recently, graphene ribbons
with suspended silicon proof masses
have been utilized as piezoresistive electromechanical transducers
in NEMS accelerometers with direct electrical readout.[46] In these devices, an acceleration force acting
on the proof mass caused a deflection of the mass. This in turn caused
a change of the strain in the suspended graphene ribbons, resulting
in a change of the electrical resistances of the graphene ribbons
because of the piezoresistivity of graphene. Although these devices
were very small and sensitive, they had limitations such as relatively
weak robustness, relatively low manufacturing yield, and part of them
that had narrow ribbons did not survive high measurement currents.
In the present paper, we report on piezoresistive NEMS accelerometer
devices that are based on fully clamped graphene membranes with suspended
silicon proof masses, featuring several advantages over the previously
demonstrated graphene ribbon devices, including improved mechanical
robustness, suspension of larger silicon proof masses, high manufacturing
yields of up to ∼80%, and the capability to withstand higher
measurement currents.To demonstrate the utility of suspended
graphene membranes with
attached silicon proof masses as piezoresistive NEMS accelerometers,
we have realized several device variations with different membrane
and proof mass dimensions, all consisting of a suspended double-layer
graphene membrane that is clamped at its entire circumference and
that contains an attached silicon proof mass at its center (Figure a). The working principle
of our devices is based on the displacement of the proof mass that
is caused by a force from external acceleration acting on the proof
mass. The proof mass displacement results in a change of the strain
in the suspended sections of the graphene membrane, thereby changing
the resistances of the corresponding suspended sections of graphene
membrane due to the piezoresistivity of graphene (Figure d1). The fabrication of our
graphene NEMS devices is depicted in Figure b with details of device fabrication described
in Methods. Briefly, chemical vapor deposition
(CVD)[47] graphene was transferred from the
original copper substrate to the silicon-on-insulator (SOI) device
substrate, thereby suspending graphene over the 16.4 μm deep
through-etched trenches in the oxidized silicon device layer of the
SOI device substrate (Figure b1 and Supporting Information Figure S1 and S2). The silicon handle layer of the SOI substrate was
removed in the areas below the trenches in the silicon device layer
by deep reactive ion etching (DRIE), prior to graphene transfer and
patterning (Figure b2). The graphene was then lithographically patterned using O2 plasma etching. Thus, the proof masses defined in the silicon
device layer of the SOI substrate were sandwiched between the graphene
membranes and the buried SiO2 (BOX) layer of the SOI substrate
(Figure b3). In a
final step, the BOX layer was sacrificially removed by dry plasma
etching, followed by vapor HF etching to release the silicon proof
masses and suspend them on the graphene membranes (Figure b4). After device fabrication,
the devices were placed in a ceramic chip package and wire-bonded. Figure c shows photographs
of two packaged chips (Figure c1,c2), scanning electron microscope (SEM) images of the two
wire-bonded devices of the two packaged chips (Figure c3,c4), and close-up images of the sensing
regions of the corresponding devices (Figure c5,c6). The two devices shown in Figure c5,c6 represent two
basic device designs with different geometric shapes of the graphene
patch. The device shown in Figure c5 had a narrow graphene patch (we call it “type
a” for short), whereas the device shown in Figure c6 had a wide graphene patch
(we call it “type b” for short). The proof masses of
all fabricated devices were 16.4 μm thick, including a 15 μm
thick silicon layer and a 1.4 μm thick SiO2 layer,
and all proof masses had a quadratic shape with different side lengths
ranging from 10 to 100 μm. The proof mass size of 100 μm
× 100 μm × 16.4 μm was the largest proof mass
that we attempted to realize. The trench widths, that is, the dimension
defining the length of the freely suspended sections of the graphene
membranes, ranged from 2 to 4 μm, depending on the device dimensions.
Figure 1
Suspended
graphene membrane with attached silicon proof mass as
piezoresistive NEMS accelerometers. (a) Three dimensional illustration
of the device design. (b) Schematic of device fabrication. b1: Ti/Au
electrodes are embedded into a 1.4 μm thick SiO2 layer
of an SOI substrate. Trenches were etched in the 15 μm thick
silicon device layer of the SOI substrate to form the silicon proof
mass. b2: The 400 μm thick silicon handle layer of the SOI substrate
was etched by DRIE in the areas below the proof masses, leaving the
silicon proof masses suspended on the BOX layer. b3: Double-layer
graphene was transferred to the SiO2 surface of the SOI
substrate and patterned by photoresist masking and O2 plasma
etching. b4: The silicon proof masses were released by sacrificially
etching the BOX layer in a two-step etching process, using first RIE
etching followed by vapor HF etching. (c) Packaging and wire bonding
of the devices. c1,c2: Photographs of two packaged and wire bonded
dies with type a devices and type b devices, respectively. c3,c5:
SEM images of a type a device from (c1) and the corresponding close-up.
c4,c6: SEM images of a type b device from (c2) and the corresponding
close-up. The trench width in the device in c5 was 3 μm while
the trench width in the device in c6 was 4 μm. The side lengths
of the squared masses in the devices in c5 and c6 were 40 and 100
μm, respectively. (d) Transduction principle and equivalent
resistance model of the graphene devices. d1: Cross-sectional 3D illustration
of a fully clamped graphene membrane with attached proof mass. The
deflection of the proof mass and the resulting strain in the suspended
graphene sections causes resistance changes in the suspended graphene
due to the piezoresistivity of the graphene. d2: Equivalent resistance
model of the graphene devices. The resistances of graphene areas on
the SiO2 surface are represented by R1l and R (R1l = R1r = R1), R3t and R3b (R3t = R3b = R3), and R8 respectively. The resistances of the suspended
graphene sections over the trenches are represented by R5l and R5r (R5l = R5r = R5), and R7t and R7b respectively (R7t = R7b = R7).
Suspended
graphene membrane with attached silicon proof mass as
piezoresistive NEMS accelerometers. (a) Three dimensional illustration
of the device design. (b) Schematic of device fabrication. b1: Ti/Au
electrodes are embedded into a 1.4 μm thick SiO2 layer
of an SOI substrate. Trenches were etched in the 15 μm thick
silicon device layer of the SOI substrate to form the silicon proof
mass. b2: The 400 μm thick silicon handle layer of the SOI substrate
was etched by DRIE in the areas below the proof masses, leaving the
silicon proof masses suspended on the BOX layer. b3: Double-layer
graphene was transferred to the SiO2 surface of the SOI
substrate and patterned by photoresist masking and O2 plasma
etching. b4: The silicon proof masses were released by sacrificially
etching the BOX layer in a two-step etching process, using first RIE
etching followed by vapor HF etching. (c) Packaging and wire bonding
of the devices. c1,c2: Photographs of two packaged and wire bonded
dies with type a devices and type b devices, respectively. c3,c5:
SEM images of a type a device from (c1) and the corresponding close-up.
c4,c6: SEM images of a type b device from (c2) and the corresponding
close-up. The trench width in the device in c5 was 3 μm while
the trench width in the device in c6 was 4 μm. The side lengths
of the squared masses in the devices in c5 and c6 were 40 and 100
μm, respectively. (d) Transduction principle and equivalent
resistance model of the graphene devices. d1: Cross-sectional 3D illustration
of a fully clamped graphene membrane with attached proof mass. The
deflection of the proof mass and the resulting strain in the suspended
graphene sections causes resistance changes in the suspended graphene
due to the piezoresistivity of the graphene. d2: Equivalent resistance
model of the graphene devices. The resistances of graphene areas on
the SiO2 surface are represented by R1l and R (R1l = R1r = R1), R3t and R3b (R3t = R3b = R3), and R8 respectively. The resistances of the suspended
graphene sections over the trenches are represented by R5l and R5r (R5l = R5r = R5), and R7t and R7b respectively (R7t = R7b = R7).Because of the complex series-parallel
resistance connection in
fully clamped graphene membranes, we developed a resistance model
to analyze the resistance change of the suspended sections of the
graphene membranes. A schematic of the equivalent resistance model
of our devices is shown in Figure d2, where R is the measured overall
resistance of the graphene device, R1l is the resistance of the nonsuspended graphene section between the
left electrode and the left trench, R1r is the resistance of the nonsuspended graphene section between right
electrode and right trench, R3t is the
resistance of the nonsuspended graphene section above the top trench, R3b is the resistance of the nonsuspended graphene
section below the bottom trench, R5l is
the resistance of the section of the suspended graphene over the left
trench, R5r is the resistance of the section
of the suspended graphene over the right trench, R7t is the resistance of the section of the suspended graphene
over the top trench, R7b is the resistance
of the section of the suspended graphene over the bottom trench, and R8 is the resistance of the section of the nonsuspended
graphene on top of the surface of the proof mass. The top, bottom,
left, and right trenches of a device are depicted in Figure c5. Assuming ideal symmetry
of the device (Figure d2), R1l = R1r = R1, R3t = R3b = R3, and R5l = R5r = R5, R7t = R7b = R7. The sheet resistance of the double-layer graphene patch is defined
as RS, and according to the square shape
of the graphene areas that define R4 and R8 it follows that R4 = R8 = RS. In this configuration, the variable resistances of the suspended
graphene sections are R5 and R7, while R1, R3, and R8 are assumed to be
constant. For a measurement current I that is applied
to a graphene device (Figure d2), the following equations can be derived based on the equivalent
resistance model (see eqs S1–S9 in Supporting Information)The change
of the overall resistance R of the
graphene device as a result of a change in strain of the suspended
graphene sections caused by a deflection of the proof-mass (ΔR) can thus be approximated byFrom eq as well
as eq S3 in the Supporting Information, it can be seen that the influence of the resistance
change in the suspended graphene sections across the top and bottom
trenches (ΔR7t and ΔR7b) on the total resistance change of a graphene
device (ΔR) can be neglected, while the resistance
changes of the suspended graphene sections over the left and right
trenches (ΔR5l and ΔR5r) are the dominant resistances contributing
to the total resistance change of the graphene device (ΔR). Therefore, in the following text we define the resistances
and resistance change of the suspended graphene sections over either
the left or the right trench as RSB and
ΔRSB, respectively, that is RSB = R5 = R5l = R5r and ΔRSB = ΔR5 =
ΔR5 = ΔR5. Equation describes the numerical relationship between
the resistance change of the suspended graphene sections over the
left and right trenches (ΔR5) and
the total resistance change of a graphene device (ΔR) and indicates that ΔR < 2ΔR5. Thus, the resistance change of the suspended
graphene sections over the left or right trenches (ΔRSB = ΔR5 =
ΔR5l = ΔR5r) can be extracted according to the corresponding overall
resistance change of the graphene device (ΔR).To evaluate the viability of our devices for detecting accelerations
we used an air-bearing shaker (PCB 396C11, The Modal Shop) with a
built-in high-precision reference accelerometer to expose our devices
to accelerations at defined frequencies. In all experiments, the devices
were placed with the sensitive axis in the direction of the earth
gravitation, providing a 1 g acceleration bias. The packaged graphene
NEMS devices were connected to signal read-out circuitry. The total
resistance of a graphene device was the input resistance in the measurement
circuit and the corresponding voltage output signal from the amplifier
circuit (amplification factor of approximately 500) was recorded by
a dynamic signal analyzer (HP 35670A, Agilent Technologies Inc.) (Methods and Supporting Information Figure S6). The spectra of the amplified output voltages (amplification
factor of approximately 500) from seven accelerometer devices (devices
a1–a7) and one reference device (reference) exposed to an acceleration
of 1g at a frequency of 160 Hz are shown in Figure a–h. In these
measurements, a bias supply current of 100 μA was supplied to
the graphene device. The reference device consisted of a graphene
patch that was similar to the graphene patches used in the accelerometer
devices, but without etched trenches in the underlying substrate surface.
Thus, no change in strain was introduced in the graphene patch of
the reference device when exposed to accelerations. The output signals
of devices a1 to a7 correlated with the acceleration, while no visible
signal was observed in the output of the reference device. This confirmed
that it was indeed the displacement of the proof mass of the accelerometer
devices that caused the measured resistance change of the graphene
and that there were no significant parasitic noise signals picked
up by the graphene devices. SEM images of devices a1–a7 and
the reference device are shown in Figure i, and detailed information about the dimensions
of each device can be found in Table S1 in the Supporting Information. As can be seen in Figure i, most of the devices contain
one or more defects such as small holes in the suspended graphene
membranes. In-plane tension, shear, and compression of the suspended
graphene, or occasional tears occurring at mechanically weak grain
boundaries of CVD graphene are some possible causes for the holes,
which were difficult to avoid during devices fabrication. Evaporation
of water that could be encapsulated in the trenches after graphene
transfer is another possible cause for rupture of the graphene membranes.
In order to systematically compare the characteristics of devices
a1–a7, they were exposed to an acceleration of 1g at a frequency of 160 Hz. The output voltage (U) and the overall measured resistance changes (ΔR) of devices a1–a7 are shown in Figure a, whereas the resulting calculated resistance
changes of the suspended parts of the graphene membranes over the
left or right trench (ΔRSB = ΔR5) and the relative resistance changes of the
suspended parts of the graphene membranes (ΔRSB/RSB) of devices a1–a7
are shown in Figure b. The absolute resistance change of the suspended graphene sections
over the left or right trenches (ΔRSB) was extracted (see Table S1 in the Supporting
Information) based on eq S9 in the Supporting Information, assuming that all suspended
graphene sections in the graphene devices are ideal (without any defects
and/or holes). Assuming that there are no defects such as holes in
the suspended graphene sections, the device geometry determines that
for an identical trench width, devices that have a smaller proof mass
also have smaller total areas of the suspended graphene sections as
compared to devices with a large proof mass. Interestingly, for device
a1 (proof mass dimension of 10 μm × 10 μm ×
16.4 μm) and device a2 (proof mass dimension of 20 μm
× 20 μm × 16.4 μm), U, ΔR, and ΔRSB were relatively
higher compared to those of device a3 (proof mass dimension of 40
μm × 40 μm × 16.4 μm), device a4 (proof
mass dimension of 40 μm × 40 μm × 16.4 μm),
and device a6 (proof mass dimension of 50 μm × 50 μm
× 16.4 μm) with all devices having 3 μm wide trenches.
However, all these devices featured similar relative resistance changes
of the suspended graphene sections (ΔRSB/RSB). This indicates that in
these devices the changes in the strain levels in the suspended graphene
sections were of the same order of magnitude, although it should be
noted that the relative resistance changes of the suspended graphene
sections have a complex dependency of the trench width and the side
length of the proof mass that determines both the mass of the proof
mass and trench length. In addition, the built-in stress in suspended
graphene sections and the number and position of the holes in the
suspended graphene sections will influence the relative resistance
changes of the suspended graphene sections. For devices with identical
proof mass dimension (50 μm × 50 μm × 16.4 μm)
and wider trenches such as device a5 (trench width of 4 μm),
the output voltage (U), the overall resistance change
of the device (ΔR), the resistance change of
the suspended graphene sections over the left or right trenches (ΔRSB) and the relative resistance change of the
suspended graphene sections (ΔRSB/RSB) were higher compared to those devices
with a narrower trench such as device a6 (trench width of 3 μm)
and device a7 (trench width of 2 μm) (Figure a,b). In order to highlight the influence
of the trench width on the output signal of a graphene device, a comparison
of the output voltages of devices a5–a7 when exposed to an
acceleration of 1g at the frequency of 160 Hz are
shown in Figure c.
In this comparison of devices with identical proof mass dimensions,
the devices with wider trenches featured larger output signals. A
similar comparison of the influence of the trench length on the output
signal is not easily possible because changing the trench length directly
also changes the size and mass of the proof mass, thereby altering
the overall device characteristics.
Figure 2
Measured spectra of the output voltages
of graphene devices (type
a). (a–h) Measured spectra of the output voltage of devices
a1–a7 and of the reference device when exposed to an acceleration
of 1g at a frequency of 160 Hz. In devices a1–a7,
the acceleration caused a deflection of the proof masses, and consequently
the strain and resistance changed in the suspended graphene sections.
This dependence on applied acceleration is not observed in the reference
device. (i) Corresponding SEM images of devices a1–a7 and the
reference device. In all devices, there are one or more small holes
in the suspended graphene sections that were caused during devices
fabrication, which could not be avoided.
Figure 3
Comparison of characteristics of the output signals of devices
a1–a7. (a) Comparison of the measured output voltages and overall
resistance changes of devices a1–a7 when exposed to an applied
acceleration of 1g at a frequency of 160 Hz. (b)
Comparison of the calculated resistance changes of the suspended graphene
sections (ΔRSB) across either the
left or the right trench and the corresponding relative resistance
changes (ΔRSB/RSB) of devices a1–a7 when exposed to an applied
acceleration of 1g at a frequency of 160 Hz. (c)
Comparison of the output voltages of devices a5–a7 when exposed
to an applied acceleration of 1g at a frequency of
160 Hz. Devices a5–a7 have proof masses with identical dimensions
(50 μm × 50 μm × 16.4 μm), but different
trench widths (4 μm for device a5, 3 μm for device a6,
and 2 μm for device a7).
Measured spectra of the output voltages
of graphene devices (type
a). (a–h) Measured spectra of the output voltage of devices
a1–a7 and of the reference device when exposed to an acceleration
of 1g at a frequency of 160 Hz. In devices a1–a7,
the acceleration caused a deflection of the proof masses, and consequently
the strain and resistance changed in the suspended graphene sections.
This dependence on applied acceleration is not observed in the reference
device. (i) Corresponding SEM images of devices a1–a7 and the
reference device. In all devices, there are one or more small holes
in the suspended graphene sections that were caused during devices
fabrication, which could not be avoided.Comparison of characteristics of the output signals of devices
a1–a7. (a) Comparison of the measured output voltages and overall
resistance changes of devices a1–a7 when exposed to an applied
acceleration of 1g at a frequency of 160 Hz. (b)
Comparison of the calculated resistance changes of the suspended graphene
sections (ΔRSB) across either the
left or the right trench and the corresponding relative resistance
changes (ΔRSB/RSB) of devices a1–a7 when exposed to an applied
acceleration of 1g at a frequency of 160 Hz. (c)
Comparison of the output voltages of devices a5–a7 when exposed
to an applied acceleration of 1g at a frequency of
160 Hz. Devices a5–a7 have proof masses with identical dimensions
(50 μm × 50 μm × 16.4 μm), but different
trench widths (4 μm for device a5, 3 μm for device a6,
and 2 μm for device a7).To demonstrate the expected linear relation between the measurement
current and the output voltage of our graphene devices, device a6
(proof mass dimensions of 50 μm × 50 μm × 16.4
μm, trench width of 3 μm, one small hole) and device a8
(proof mass dimensions of 20 μm × 20 μm × 16.4
μm, trench width of 3 μm, several larger holes) were chosen
for measurements at 1g acceleration at a frequency
of 160 Hz using different bias currents of 45 and 100 μA. The
output voltages of both devices increased approximately proportionally
with the measurement current, confirming that the measurement circuit
worked as intended, even for the device that contain several holes
in the graphene membrane (Figure a).
Figure 4
Control experiments of device output signals. (a) Measured
output
voltages versus bias currents of devices a6 and a8. The output voltage
increased nearly proportionally with the current bias, confirming
that the measurement setup works as intended. (b) Comparison of the
output voltages of devices a7, a9, and a10 when exposed to an acceleration
of 1g with a frequency of 160 Hz. Devices a7, a9,
and a10 had identical proof mass dimensions of 50 μm ×
50 μm × 16.4 μm and identical trench widths of 2
μm but different numbers and sizes of defects in the suspended
graphene membranes. Device a7 had fewer and smaller holes and featured
a relatively small output voltage while devices a9 and a10 had many
and larger holes and featured higher output voltages. This illustrates
that the number of holes in the suspended areas of the graphene influences
the signal response of a fully clamped graphene device. The large
difference of the output voltages of devices a9 and a10 illustrates
instabilities of devices with a large number of defects in the suspended
sections of the graphene membrane. (c) Comparison of the output voltages
of device a11 when exposed to accelerations at a frequency of 160
Hz for different measurements on different days. The measurement results
illustrate that device a11 with few defects in the graphene membrane
featured good repeatability. (d) Comparison of the output voltages
of device a12 when exposed to applied acceleration of 1g at a frequency of 160 Hz for different measurements on different
days. The measurement results illustrate that device a12 with a larger
number of defects in the graphene membrane featured significantly
lower measurement repeatability but increased output voltages as compared
to device a11 with fewer defects. (e) SEM images of devices a8–a12.
Devices a8–a12 were type a devices (device with narrow graphene
patch). Device a11 had only one defect and has relatively stable device
characteristics. Devices a8, a9, a10, and a12 had a large number of
defects and featured comparably unstable output signals.
Control experiments of device output signals. (a) Measured
output
voltages versus bias currents of devices a6 and a8. The output voltage
increased nearly proportionally with the current bias, confirming
that the measurement setup works as intended. (b) Comparison of the
output voltages of devices a7, a9, and a10 when exposed to an acceleration
of 1g with a frequency of 160 Hz. Devices a7, a9,
and a10 had identical proof mass dimensions of 50 μm ×
50 μm × 16.4 μm and identical trench widths of 2
μm but different numbers and sizes of defects in the suspended
graphene membranes. Device a7 had fewer and smaller holes and featured
a relatively small output voltage while devices a9 and a10 had many
and larger holes and featured higher output voltages. This illustrates
that the number of holes in the suspended areas of the graphene influences
the signal response of a fully clamped graphene device. The large
difference of the output voltages of devices a9 and a10 illustrates
instabilities of devices with a large number of defects in the suspended
sections of the graphene membrane. (c) Comparison of the output voltages
of device a11 when exposed to accelerations at a frequency of 160
Hz for different measurements on different days. The measurement results
illustrate that device a11 with few defects in the graphene membrane
featured good repeatability. (d) Comparison of the output voltages
of device a12 when exposed to applied acceleration of 1g at a frequency of 160 Hz for different measurements on different
days. The measurement results illustrate that device a12 with a larger
number of defects in the graphene membrane featured significantly
lower measurement repeatability but increased output voltages as compared
to device a11 with fewer defects. (e) SEM images of devices a8–a12.
Devices a8–a12 were type a devices (device with narrow graphene
patch). Device a11 had only one defect and has relatively stable device
characteristics. Devices a8, a9, a10, and a12 had a large number of
defects and featured comparably unstable output signals.In order to analyze the influence of the number
and dimensions
of the holes in the suspended graphene sections on the output signals
of the graphene devices, we compared measurements of devices a7, a9
and a10 when exposed to an acceleration at 1g at
a frequency of 160 Hz. Devices a7, a9, and a10 had identical proof
mass dimensions of 50 μm × 50 μm × 16.4 μm
and trench widths of 2 μm, but different numbers and dimensions
of holes in the graphene membranes, as shown in Figure i and Figure e. The comparison of the output voltage of devices
a7, a9, and a10 when exposed to an acceleration of 1g at a frequency of 160 Hz and a supply current of 100 μA was
shown in Figure b.
The results show that more holes in the graphene membrane and/or holes
with larger dimension resulted in increased resistance changes of
the devices. One possible explanation is that more holes or holes
with larger dimensions result in reduced membrane stiffness and increased
strain in the suspended graphene sections. It should be noted that
no additional holes or visible defects were generated during the acceleration
measurements (0–2g), which was verified by
SEM imaging of the graphene devices before and after the acceleration
measurements.In order to verify the stability and repeatability
of the output
signal of our graphene devices, acceleration measurements of devices
a11 and a12 were performed at different times (time span: 14 days).
These devices had identical proof mass dimensions of 15 μm ×
15 μm × 16.4 μm and an identical trench width of
4 μm but different number of defects in the suspended graphene
sections (device a11 had one hole while device a12 had three holes
as shown in Figure e). Device a11 exhibited good repeatability of the output signals
at applied accelerations (1g, 1.5g, and 2g), as shown in Figure c while device a12 presented a much lower
repeatability of the output voltages at applied accelerations (1g and 2g), as shown in Figure d. This indicates that the
number of defects in the suspended graphene sections can influence
the repeatability and stability of the output signal of a device.
One or two small holes did not significantly influence the stability
of the output signal of the graphene device (e.g., device a11) while
several larger holes had a significant impact on the stability of
the output signal of the device (e.g., device a12). This is expected
as it suggests that the better the quality and integrity of the suspended
graphene membranes, the better the repeatability of the output signals
of the device.In order to compare the influence of the geometric
design of the
graphene patch of a device on the resulting output signal, we performed
corresponding acceleration measurements of type b devices that feature
wider graphene patches than the type a devices (Figure i). Device b1 (proof mass dimensions of 10
μm × 10 μm × 16.4 μm and trench width
of 4 μm), and device b2 (proof mass dimensions of 40 μm
× 40 μm × 16.4 μm and trench width of 4 μm)
are two examples of type b device designs. The spectra of the amplified
output voltages of devices b1 and b2 exposed to an acceleration of
1g at a frequency of 160 Hz are shown in Figure a,b. The corresponding U and ΔR of devices b1 and b2 are
shown in Figure c,
and ΔRSB over the left or right
trenches and the corresponding relative resistance changes (ΔRSB/RSB) of devices
b1 and b2 are shown in Figure d. These results illustrate that type a device designs (devices
a1–a7) featured higher output signals than type b device designs
(devices b1,b2) (Figure e,f). On the basis of our resistance model of the devices, this result
is expected because the fixed resistances that are coupled in parallel
to the variable resistances are significantly larger in the type a
device designs (Figure d2). Figure e shows
the measured output voltages of devices a1 and b1 when exposed to
an acceleration of 1g at a frequency of 160 Hz. Devices
a1 and b1 had identical proof mass dimensions of 10 μm ×
10 μm × 16.4 μm. Although the trench width of device
b1 (4 μm) was larger than the trench width of device a1 (3 μm),
the output voltage of device a1 was significantly larger than that
of device b1. A comparison of the relative resistance changes of the
suspended graphene sections (ΔRSB/RSB) of devices a1 and b1 is shown in Figure f. The measured values
of ΔRSB/RSB of devices a1 and b1 were comparable, which was expected as they
had identical proof mass dimensions and similar trench widths.
Figure 5
Measured output
voltages of type b devices and comparison to type
a devices. (a,b) Measured spectra of the output voltages of devices
b1 and b2 when exposed to an applied acceleration of 1g at a frequency of 160 Hz. (c) Comparison of the output voltages
and overall resistance changes (ΔR) of devices
b1 and b2 when exposed to an applied acceleration of 1g at a frequency of 160 Hz. (d) Comparison of the calculated resistance
change of the suspended graphene section (ΔRSB) in either the left or the right trench and corresponding
relative resistance change (ΔRSB/RSB) of devices b1 and b2 when exposed
to an applied acceleration of 1g with a frequency
of 160 Hz. (e) Comparison of the output voltages of devices a1 and
b1 when exposed to an acceleration of 1g at a frequency
of 160 Hz. Devices a1 and b1 had identical proof mass dimensions of
10 μm × 10 μm × 16.4 μm and similar trench
widths (3 μm for device a1 and 4 μm for device b1), but
device a1 was a type a device design (device with a narrow graphene
patch) while device b1 was a type b device design (device with a wide
graphene patch). The results of (e) illustrate that type a designs
typically featured higher signal responses than type b designs under
identical conditions. (f) Comparison of the calculated relative resistance
changes of the suspended graphene section (ΔRSB/RSB) of devices a1 and
b1 when exposed to an acceleration of 1g at a frequency
of 160 Hz, respectively. (g) SEM images of devices b1 and b2 (type
b).
Measured output
voltages of type b devices and comparison to type
a devices. (a,b) Measured spectra of the output voltages of devices
b1 and b2 when exposed to an applied acceleration of 1g at a frequency of 160 Hz. (c) Comparison of the output voltages
and overall resistance changes (ΔR) of devices
b1 and b2 when exposed to an applied acceleration of 1g at a frequency of 160 Hz. (d) Comparison of the calculated resistance
change of the suspended graphene section (ΔRSB) in either the left or the right trench and corresponding
relative resistance change (ΔRSB/RSB) of devices b1 and b2 when exposed
to an applied acceleration of 1g with a frequency
of 160 Hz. (e) Comparison of the output voltages of devices a1 and
b1 when exposed to an acceleration of 1g at a frequency
of 160 Hz. Devices a1 and b1 had identical proof mass dimensions of
10 μm × 10 μm × 16.4 μm and similar trench
widths (3 μm for device a1 and 4 μm for device b1), but
device a1 was a type a device design (device with a narrow graphene
patch) while device b1 was a type b device design (device with a wide
graphene patch). The results of (e) illustrate that type a designs
typically featured higher signal responses than type b designs under
identical conditions. (f) Comparison of the calculated relative resistance
changes of the suspended graphene section (ΔRSB/RSB) of devices a1 and
b1 when exposed to an acceleration of 1g at a frequency
of 160 Hz, respectively. (g) SEM images of devices b1 and b2 (type
b).In summary, we have demonstrated
that proof masses with dimensions
of at least up to 100 μm × 100 μm × 16.4 μm
can be suspended on membranes made of double-layer graphene. These
devices can be utilized as piezoresistive NEMS accelerometer devices,
where there exist trade-offs between device miniaturization (proof
mass dimensions and trench widths), resulting output signal, device
robustness, and measurable acceleration range. AFM indentation experiments
demonstrated that a device with a 3 μm wide trench and a proof
mass size of 10 μm × 10 μm × 16.4 μm was
able to withstand an indentation force at the proof mass center of
up to 4070 nN and ruptured at an indentation force of 5051 nN (Supporting
Information Figure S7 and Table S2). For reference, this can be compared to the resulting
force of about 0.039 nN resulting from an acceleration of 1g on a proof mass of the size of 10 μm × 10 μm
× 16.4 μm. We hypothesize that device designs with annular
graphene membranes and proof masses may feature even higher mechanical
robustness by avoiding corners that are prone to stress concentrations.
In addition, annular device design would feature uniform strain distribution
in all suspended graphene sections. Furthermore, it should be noted
that the adhesion between a graphene sheet and a SiO2 surface
is known to be ultrastrong.[48] Thus, any
realistic acceleration force we do in our devices do not expect delamination
of the graphene from the substrate or the proof mass. Compared to
state-of-the-art silicon MEMS accelerometers, our NEMS accelerometer
structures feature at least 3 orders of magnitude smaller proof masses,[49−54] while still providing useful output signals. Consequently, our devices
occupy at least 2 orders of magnitude small die areas, thereby demonstrating
the huge potential of this approach for device scaling and cost reduction.
In addition, there is further potential for reducing dimensions in
our graphene devices by minimizing the electrical contact areas and
by using state-of-the-art device packaging strategies.[55] Compared to our recent study on devices based
on graphene ribbons with suspended silicon proof masses,[46] the fully clamped graphene membrane devices
feature improved fabrication yield, improved robustness, a potentially
longer life span, and the potential to measure higher accelerations,
and they can suspend larger proof masses and have the capability to
withstand higher measurement currents. We have applied measurement
currents of up to 200 μA to our graphene membrane devices and
we did not observe failure of any of the devices caused by the measurement
currents. The capability to withstand higher measurement currents
of devices made of fully clamped graphene membranes is presumably
a result of lower current densities for a given bias voltage in the
graphene membranes compared to the graphene ribbons. However, the
signal response of the devices with fully clamped graphene membranes
is generally lower than that of devices with doubly clamped graphene
ribbons for devices with identical proof masses and trench width.
One reason for this is that for exposure to a given acceleration,
significantly larger strain changes will be generated in narrow graphene
ribbons with a proof mass as compared to suspending the identical
proof mass on a graphene membrane that is fully clamped at its circumference.
Another important reason is that the unavoidable parallel connected
fixed graphene resistances in devices with fully clamped graphene
membranes significantly reduces the overall resistance response of
these designs as compared to the simple series connection of the variable
graphene resistances in devices based on graphene ribbons with a suspended
proof mass.[46] Although the piezoresistivity
of graphene is most likely the dominant transduction mechanism in
our devices, it is possible that changes of the interlayer interaction
in double-layer graphene, such as sliding of individual graphene layers
with respect to each other, can contribute to the measured resistance
changes in our devices.[56] However, this
effect is not likely to cause significant resistance changes in our
graphene membranes because the required forces and membrane displacements
indicated by Benameur et al.[56] to cause
measurable resistance changes by this effect are much larger than
the forces occurring in our acceleration.In conclusion, the
proposed fully clamped graphene membranes with
attached silicon proof masses for use in piezoresistive NEMS accelerometers
feature excellent characteristics, including improved robustness,
improved manufacturing yield, longer lifetime, the capability to withstand
higher measurement currents and the potential to suspend larger proof
masses than similar structures previously reported. These characteristics
will contribute to bringing ultraminiaturized piezoresistive graphene
NEMS closer toward deployment in potential applications, spanning
several important scientific and technological areas, such as IoT,
biomedical implants, nanoscale robotics, and wearable electronics.
Methods
Device
Fabrication
Devices were fabricated from a SOI
wafer in which the silicon device layer was 15 μm thick, the
BOX layer was 2 μm thick, and the handle substrate was 400 μm
thick (Figure a).
First, a 1.4 μm thick layer of SiO2 was thermally
grown on both the front and the backside of the SOI wafer (Figure a). Next, a photoresist
layer was spin-coated on the SiO2 surface of the silicon
device layer and patterned to define the metal electrodes. The pattern
was transferred into the 1.4 μm thick SiO2 layer
by etching 300 nm deep cavities using reactive ion etching (RIE).
The cavities were filled with a 50 nm thick layer of titanium (Ti)
followed by a 270 nm thick layer of gold (Au) using metal evaporation.
The photoresist layer was removed in a lift-off process by wet etching,
leaving the patterned Au electrodes to protrude by about 20 nm above
the SiO2 surface. A new photoresist layer was spin-coated
on the SiO2 surface and lithographically patterned for
defining the trenches surrounding the proof masses. RIE was used to
etch through the 1.4 μm thick SiO2 layer and DRIE
was used to etch through the 15 μm thick silicon device layer
(Figure b1). After
the DRIE, photoresist residues were removed by O2 plasma
etching. Next, a photoresist layer was spin-coated and patterned on
the SiO2 surface of the backside of the SOI wafer, defining
squares with dimensions of 150 μm × 150 μm placed
in the same areas that define the proof masses in the silicon device
layer. Using this mask, the 1.4 μm thick SiO2 layer
was etched by RIE. Next, the handle substrate was etched by DRIE until
reaching the BOX, using both the photoresist and the SiO2 as masking layers, thereby forming the channel to release the proof
mass in a later process step. Photoresist residues were removed by
O2 plasma etching, which finalized the preprocessing of
the SOI device substrate (Figure b2). The device substrate was then diced in 8 mm ×
8 mm large chips, each containing 64 devices.Commercially available
CVD single-layer graphene on copper foil (Graphenea, Spain) was used
in this work. Double-layer graphene was obtained by transferring a
single-layer graphene to another single-layer graphene on a copper
foil. Therefore, a poly(methyl methacrylate) (PMMA) solution (AR-P
649.04, ALLRESIST, Germany) was spin-coated on the front-side of the
first graphene/copper foils at 500 rpm for 5 s and at 1800 rpm for
30 s and then baked for 5 min at 85 °C on a hot plate to evaporate
the solvent and cure the PMMA, resulting in a PMMA film thickness
of about 200 nm. Carbon residues on the backside of the copper foil
were removed using O2 plasma etching at low power (50–80
W). In order to release the graphene/PMMA stack from the copper, the
foil was placed onto the surface of an iron chloride (FeCl3) solution with the graphene side facing away from the liquid, resulting
in wet etching of the copper. After 2 h, the PMMA/graphene stack was
transferred onto the surface of deionized (DI) water, then diluted
HCl solution, and then back to DI water for cleaning, removing the
iron(III) residues, and removing chloride residues, respectively.
A silicon wafer was used for handling and picking up the PMMA/graphene
stack from the liquids. A second graphene on copper foil was used
and the PMMA/graphene stack floating on the DI water was transferred
to the second graphene on copper foil and subsequently put on a hot
plate at 45 °C to increase the adhesion between the two graphene
layers. Carbon residues on the backside of the copper foil were removed
using O2 plasma etching. Again, the same processes were
performed to remove the copper substrate from the double-layer graphene
and transfer the final PMMA/double-layer graphene stack to the preprocessed
SOI device substrate. The SOI device substrate was then baked for
∼10 min at ∼45 °C in order to dry it and to increase
the bond strength between the double-layer graphene and the SiO2 surface. Next, the SOI device substrate was placed in acetone
to remove the PMMA and subsequently in isoproponal to remove acetone
residues. It should be noted that even after an exhaustive rinse with
organic solvents, there are some PMMA residues (long-chain molecules)
remaining on the graphene (Figure S1 in
Supporting Information) due to the strong dipole interactions between
PMMA and the chemical groups on graphene.[57] After the graphene transfer, a photoresist layer was spin-coated
on the graphene at 1000 rpm for 5 s and 4000 rpm for 60 s and then
baked on a hot plate for 30–60 s at 90 °C. Optical lithography
and photoresist development were done using a standard developer for
15 s and DI water for 10 s for rinsing, and then the SOI substrate
was dried in air. Next, the graphene was etched by O2 plasma
at 50 W for 120 s to define the outline of the patches with graphene
membranes. In order to remove the photoresist residues, the device
substrate was placed in acetone for 20 min and then in isopropanol
for 5 min, followed by baking at 45 °C for 10 min on a hot plate
(Figure b3).In order to release the proof masses and suspend them on the double-layer
graphene membranes, the BOX layer (2 μm thick SiO2) was partly etched from the backside of the SOI substrate by RIE,
followed by vapor HF etch to remove the remaining SiO2 layer
(Figure b4). This
two-step etching process was employed to minimize the risk of damaging
the graphene. For etching the BOX layer, the device substrate was
attached to a 100 mm diameter silicon carrier wafer and the four edges
on the sides of the device substrate were sealed with a tape. Then
RIE etching was employed to etch approximately 1.9 μm of the
BOX layer, leaving an ∼100 nm thin BOX layer that was suspending
the silicon proof masses. Vapor HF was then used to etch the remaining
BOX layer using a custom-built vapor HF etching setup. Twenty-five
percent of HF was used in the vapor HF chamber and the temperature
was set to 40 °C. The etching of the ∼100 nm thick BOX
layer typically took 5–10 min. Once the device fabrication
was complete, the chips were glued in a ceramic chip package with
an open cavity. Next, gold wire bonding was used to connect the electrode
pads on the device substrate to the bond pads in the chip package
as shown in Figure c. Our fabrication process resulted in a fabrication yield of about
80% of fully clamped double-layer graphene membranes with attached
silicon proof masses that were electrically active. Our graphene devices
(both type a and type b devices) were functioning after elaborate
acceleration measurements and most of the time even after exposure
to shocks during device handling. Only in very rare cases were devices
damaged when exposed to excessive shocks during handling. This illustrates
the increased robustness, fracture toughness,[58] and life-span of the devices compared to devices based on doubly
clamped graphene ribbons that were in many cases damaged when exposed
to shocks during handling. It should be noted that our fabrication
yield was very low (on the order of 1%) when we attempted to realize
membranes made of single-layer graphene with attached silicon proof
masses, and it was very difficult to manually handle these devices
without breaking them. Although CVD graphene intrinsically comprises
grains and grain boundaries that might influence the mechanical strength
and fracture toughness of CVD graphene, our experimental results illustrate
that for a suspended structure made of CVD graphene, the addition
of a second layer of CVD graphene on top of a first CVD graphene layer
disproportionally increases the fracture toughness of the resulting
structure. This is consistent with literature reports showing that
suspended membranes made of double-layer CVD graphene have a better
overall mechanical resilience compared to suspended membranes made
of single-layer CVD graphene.[58] However,
if single-layer graphene devices can be successfully fabricated they
potentially would feature higher output signals as compared to double-layer
graphene devices due to the reduced stiffness of single-layer graphene
membranes. We also hypothesize that trilayer or multilayer graphene
membranes in our devices would further increase the fabrication yield
but likely result in reduced output signals.
Characterizations and Measurements
Optical microscopy,
white light interferometry (Wyko NT9300, Veeco), and SEM imaging were
used to observe and characterize the morphology of the devices during
and after device fabrication (Figures S1–S4 in Supporting Information). SEM imaging was used to evaluate graphene
membranes and suspended proof masses after they were released by sacrificial
etching of the BOX layer (Figure S1 and S2 in Supporting Information). White light interferometry was used
to detect SiO2 residues inside the trenches to verify that
the masses were fully released and to measure the deflection of the
silicon proof masses in relation to the substrate surface after release
of the proof masses (Figures S3 and S4 in
Supporting Information). Raman spectrometry (alpha300 R, WITec) was
used to verify the presence and quality of the double-layer graphene
of a fabricated device (Figure S5 in Supporting
Information). An atomic force microscope (AFM) (Dimension Icon, Bruker)
with a cantilever (Olympus AC240TM) and an AFM tip (tip radius = 15
nm) was used to load defined forces at the center of a proof mass
of a graphene device to measure the force versus proof mass displacement
as well as the maximum force that the suspended graphene membrane
can withstand without rupture (Figure S7 and Table S2 in Supporting Information).
A probe-station connected to a parameter analyzer (Keithley SCS4200,
Tektronix) was used for preliminary electrical characterization of
graphene devices. A special box with a complete low-frequency electromagnetic
shielding was designed to shield the graphene devices from mechanical
and electrical noise interferences of the measurement system and the
environment. Both the device package and the electronic measurement
circuits were encapsulated in this box but were separated by ferromagnetic
alloy inside the box to reduce crosstalk between the graphene devices
and the measurement circuit. The air-bearing shaker and the dynamic
signal analyzer were controlled by a computer interface to apply a
defined acceleration for the packaged devices and to read out the
sensing signal in the form of an output voltage, respectively. In
all experiments we used an acceleration frequency of 160 Hz with a
1 g gravitation bias. The acceleration frequency of 160 Hz was used
because on one hand, this frequency is sufficiently high to obtain
relatively low 1/f-noise and is sufficiently close
to 159.2 Hz, which is a commonly used frequency for accelerometer
calibrators and is equivalent to a radian frequency of 1000 rad/s
(equivalent to 2 × π × 159.2),[59] and on the other hand it is well below the intrinsic resonance
frequencies of the spring-mass systems of our devices. In addition,
160 Hz avoids the commonly known 50 Hz noise sources and its multiples.
The measurement circuits consisted of a first-order high-pass filter
with a cut off frequency of 0.079 Hz and a preamplifier (LT1001OP,
Linear Technology) with an amplification factor of approximately 500.
The resistance of the graphene patch of a device was used as the input
resistance of the first-order high-pass filter, supplied with an adjustable
direct current (dc). Unless stated differently, in all experiments
a bias current of 100 μA was used and the measurements were
performed in atmospheric conditions. When the proof mass was displaced,
the suspended sections of the graphene membrane were strained and
their resistances changed due to the piezoresistivity of graphene.
The output voltage induced by the change of the graphene resistance
was read by the first-order high-pass filter with a cutoff frequency
of 0.079 Hz to filter any dc drift observed in the graphene resistors,
amplified by the amplifier, read by a first-order high-pass filter
with a cutoff frequency of 15 Hz and then recorded by a dynamic signal
analyzer (HP 35670A), and finally recorded through the computer interface
(Figure S6 in Supporting Information).
According to U, the corresponding resistance change
of graphene devices can be directly extracted by ΔR = U/(500 × I). Before and
after each measurement, a multimeter was used to measure the resistance
of the graphene patch in order to confirm that the graphene membrane
with the suspended mass was intact before and after the measurements.
In addition, optical microscopy and SEM imaging were used to confirm
the mechanical integrity of the devices after the measurements. All
characterizations and measurements were performed in air at atmospheric
pressure.
Authors: J Scott Bunch; Arend M van der Zande; Scott S Verbridge; Ian W Frank; David M Tanenbaum; Jeevak M Parpia; Harold G Craighead; Paul L McEuen Journal: Science Date: 2007-01-26 Impact factor: 47.728
Authors: Matthias Goldsche; Jens Sonntag; Tymofiy Khodkov; Gerard Jan Verbiest; Sven Reichardt; Christoph Neumann; Taoufiq Ouaj; Nils von den Driesch; Dan Buca; Christoph Stampfer Journal: Nano Lett Date: 2018-02-16 Impact factor: 11.189
Authors: Dejan Davidovikj; Paul H Scheepers; Herre S J van der Zant; Peter G Steeneken Journal: ACS Appl Mater Interfaces Date: 2017-11-30 Impact factor: 9.229
Authors: Robin J Dolleman; Dejan Davidovikj; Santiago J Cartamil-Bueno; Herre S J van der Zant; Peter G Steeneken Journal: Nano Lett Date: 2015-12-29 Impact factor: 11.189
Authors: Muhammed M Benameur; Fernando Gargiulo; Sajedeh Manzeli; Gabriel Autès; Mahmut Tosun; Oleg V Yazyev; Andras Kis Journal: Nat Commun Date: 2015-10-20 Impact factor: 14.919
Authors: Dejan Davidovikj; Menno Poot; Santiago J Cartamil-Bueno; Herre S J van der Zant; Peter G Steeneken Journal: Nano Lett Date: 2018-04-17 Impact factor: 11.189
Authors: D Davidovikj; F Alijani; S J Cartamil-Bueno; H S J van der Zant; M Amabili; P G Steeneken Journal: Nat Commun Date: 2017-11-01 Impact factor: 14.919
Authors: Arne Quellmalz; Xiaojing Wang; Simon Sawallich; Burkay Uzlu; Martin Otto; Stefan Wagner; Zhenxing Wang; Maximilian Prechtl; Oliver Hartwig; Siwei Luo; Georg S Duesberg; Max C Lemme; Kristinn B Gylfason; Niclas Roxhed; Göran Stemme; Frank Niklaus Journal: Nat Commun Date: 2021-02-10 Impact factor: 14.919
Authors: Battulga Munkhbat; Andrew B Yankovich; Denis G Baranov; Ruggero Verre; Eva Olsson; Timur O Shegai Journal: Nat Commun Date: 2020-09-14 Impact factor: 14.919