Ambulatory measurement of arm orientation.

H J Luinge1, P H Veltink, C T M Baten.   

Abstract

In order to evaluate the impact of neuromuscular disorders affecting the upper extremities, the functional use of the arm need to be evaluated during daily activities. A system suitable for measuring arm kinematics should be ambulatory and not interfere with activities of daily living. A measurement system based on miniature accelerometers and gyroscopes is adequate because the sensors are small and do not suffer from line of sight problems. A disadvantage of such sensors is the cumulative drift around the vertical and the problems with aligning the sensor with the segment. A method that uses constraints in the elbow to measure the orientation of the lower arm with respect to the upper arm is described. This requires a calibration method to determine the exact orientation of each of the sensors with respect to the segment. Some preliminary measurements were analyzed and they indicated a strong reduction in orientation error around the vertical. It seemed that the accuracy of the method is limited by the accuracy of the sensor to segment calibration.

Entities:  

Mesh:

Year:  2006        PMID: 16455089     DOI: 10.1016/j.jbiomech.2005.11.011

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  58 in total

1.  Automatic individual calibration in fall detection--an integrative ambulatory measurement framework.

Authors:  Jian Liu; Thurmon E Lockhart
Journal:  Comput Methods Biomech Biomed Engin       Date:  2011-12-08       Impact factor: 1.763

2.  Real-Time Arm Tracking for HMI Applications.

Authors:  Matthew Masters; Luke Osborn; Nitish Thakor; Alcimar Soares
Journal:  Int Conf Wearable Implant Body Sens Netw       Date:  2015-10-19

3.  Quadrupedal Locomotion-Respiration Entrainment and Metabolic Economy in Cross-Country Skiers.

Authors:  Kevin Boldt; Anthony Killick; Walter Herzog
Journal:  J Appl Biomech       Date:  2015-08-06       Impact factor: 1.833

4.  Ambulatory measurement of shoulder and elbow kinematics through inertial and magnetic sensors.

Authors:  Andrea Giovanni Cutti; Andrea Giovanardi; Laura Rocchi; Angelo Davalli; Rinaldo Sacchetti
Journal:  Med Biol Eng Comput       Date:  2007-12-18       Impact factor: 2.602

5.  Inertial and time-of-arrival ranging sensor fusion.

Authors:  Paul Vasilyev; Sean Pearson; Mahmoud El-Gohary; Mateo Aboy; James McNames
Journal:  Gait Posture       Date:  2017-02-20       Impact factor: 2.840

6.  Validation of inertial measurement units with an optoelectronic system for whole-body motion analysis.

Authors:  Xavier Robert-Lachaine; Hakim Mecheri; Christian Larue; André Plamondon
Journal:  Med Biol Eng Comput       Date:  2016-07-05       Impact factor: 2.602

7.  IMU-based sensor-to-segment multiple calibration for upper limb joint angle measurement-a proof of concept.

Authors:  Mahdi Zabat; Amina Ababou; Noureddine Ababou; Raphaël Dumas
Journal:  Med Biol Eng Comput       Date:  2019-08-30       Impact factor: 2.602

8.  Assessing Shoulder Biomechanics of Healthy Elderly Individuals During Activities of Daily Living Using Inertial Measurement Units: High Maximum Elevation Is Achievable but Rarely Used.

Authors:  Ryan M Chapman; Michael T Torchia; John-Erik Bell; Douglas W Van Citters
Journal:  J Biomech Eng       Date:  2019-04-01       Impact factor: 2.097

9.  Ambulatory human motion tracking by fusion of inertial and magnetic sensing with adaptive actuation.

Authors:  H Martin Schepers; Daniel Roetenberg; Peter H Veltink
Journal:  Med Biol Eng Comput       Date:  2009-12-17       Impact factor: 2.602

10.  A Nonlinear Dynamics-Based Estimator for Functional Electrical Stimulation: Preliminary Results From Lower-Leg Extension Experiments.

Authors:  Marcus Allen; Qiang Zhong; Nicholas Kirsch; Ashwin Dani; William W Clark; Nitin Sharma
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2017-09-07       Impact factor: 3.802

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.