Literature DB >> 31471328

Automated anterior chamber angle pigmentation analyses using 360° gonioscopy.

Masato Matsuo1, Simone Pajaro2, Andrea De Giusti2, Masaki Tanito3.   

Abstract

PURPOSE: To assess the pigmentation distribution in the iridocorneal angle using an established algorithm with gonioscopically obtained images.
METHODS: Manual and automatically modified Scheie's pigmentation grading (ie, 0/I=0, II=1 and III/IV=2) of trabecular meshwork was performed using an established algorithm on the 75 open-angle eyes of 75 subjects obtained by automated gonioscopy. All images were collected at the Matsue Red Cross Hospital in 2016. The differences in the pigmentation density were compared statistically between the automated and manual techniques and among the four sectors (ie, inferior, superior, temporal and nasal) and the four quadrants.
RESULTS: There was substantial agreement between both grading methods (kappa value=0.70). There was no significant difference between the automated and manual grading in any sectors except for the superior (p=0.0004). The automated pigmentation grade was significantly (p<0.05) higher in the inferior sector (mean grade, 1.43) than in the others (mean grade, 0.48~0.76), and it was also significantly (p<0.05) higher in the inferior quadrant (mean grade, 3.56) than in the others (mean grade, 1.64~2.24). The findings were similar for manual grading.
CONCLUSIONS: The entire distribution of the pigmentation in the anterior chamber angle was classified successfully using the algorithm, and the automated versus manual grading comparison showed good agreement. The automated pigmentation grading scores in the inferior sector and inferior quadrant were significantly higher than in the others as previously reported. Similar findings also were seen for manual grading. © Author(s) (or their employer(s)) 2020. No commercial re-use. See rights and permissions. Published by BMJ.

Entities:  

Keywords:  angle; anterior chamber; diagnostic tests/investigation; glaucoma; imaging

Mesh:

Year:  2019        PMID: 31471328     DOI: 10.1136/bjophthalmol-2019-314320

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  4 in total

1.  Intraobserver and interobserver agreement among anterior chamber angle evaluations using automated 360-degree gonio-photos.

Authors:  Masato Matsuo; Shiro Mizoue; Koji Nitta; Yasuyuki Takai; Kazunobu Sugihara; Masaki Tanito
Journal:  PLoS One       Date:  2021-05-06       Impact factor: 3.240

2.  Characterization of Peripheral Anterior Synechiae Formation After Microhook Ab-interno Trabeculotomy Using a 360-Degree Gonio-Camera.

Authors:  Masato Matsuo; Yuina Inomata; Nana Kozuki; Masaki Tanito
Journal:  Clin Ophthalmol       Date:  2021-04-19

3.  Automated Focal Plane Merging From a Stack of Gonioscopic Photographs Using a Focus-Stacking Algorithm.

Authors:  Masato Matsuo; Nana Kozuki; Yuina Inomata; Yoshiki Kumagai; Ryosuke Shiba; Koji Hamaguchi; Masaki Tanito
Journal:  Transl Vis Sci Technol       Date:  2022-04-01       Impact factor: 3.048

Review 4.  Moving beyond the Slit-Lamp Gonioscopy: Challenges and Future Opportunities.

Authors:  Carlo Alberto Cutolo; Chiara Bonzano; Riccardo Scotto; Michele Iester; Alessandro Bagnis; Chiara Pizzorno; Carlo Catti; Carlo Enrico Traverso
Journal:  Diagnostics (Basel)       Date:  2021-12-06
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.