Literature DB >> 31465366

Coextensive synchronized SLO-OCT with adaptive optics for human retinal imaging.

Mehdi Azimipour, Ravi S Jonnal, John S Werner, Robert J Zawadzki.   

Abstract

We describe the details of a multimodal retinal imaging system which combines adaptive optics (AO) with an integrated scanning light ophthalmoscopy (SLO) and optical coherence tomography (OCT) imaging system. The OCT subsystem consisted of a swept-source, Fourier-domain mode-locked (FDML) laser, with a very high A-scan rate (1.6 MHz), whose beam was raster scanned on the retina by two scanners-one resonant scanner and one galvanometer. The high sweep rate of the FDML permitted the SLO and OCT to utilize the same scanners for in vivo retinal imaging and, unlike existing multimodal systems, concurrently acquired SLO frames and OCT volumes with approximate en face correspondence at a rate of 6 Hz. The AO provided diffraction-limited cellular resolution for both imaging channels.

Entities:  

Year:  2019        PMID: 31465366      PMCID: PMC6887517          DOI: 10.1364/OL.44.004219

Source DB:  PubMed          Journal:  Opt Lett        ISSN: 0146-9592            Impact factor:   3.776


  31 in total

1.  Visualization of wave-guide modes in retinal receptors.

Authors:  J M ENOCH
Journal:  Am J Ophthalmol       Date:  1961-05       Impact factor: 5.258

Review 2.  Maximum permissible exposures for ocular safety (ANSI 2000), with emphasis on ophthalmic devices.

Authors:  François C Delori; Robert H Webb; David H Sliney
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2007-05       Impact factor: 2.129

3.  Adaptive optics parallel spectral domain optical coherence tomography for imaging the living retina.

Authors:  Yan Zhang; Jungtae Rha; Ravi Jonnal; Donald Miller
Journal:  Opt Express       Date:  2005-06-13       Impact factor: 3.894

4.  Adaptive-optics optical coherence tomography for high-resolution and high-speed 3D retinal in vivo imaging.

Authors:  Robert J Zawadzki; Steven M Jones; Scot S Olivier; Mingtao Zhao; Bradley A Bower; Joseph A Izatt; Stacey Choi; Sophie Laut; John S Werner
Journal:  Opt Express       Date:  2005-10-17       Impact factor: 3.894

5.  Imaging individual neurons in the retinal ganglion cell layer of the living eye.

Authors:  Ethan A Rossi; Charles E Granger; Robin Sharma; Qiang Yang; Kenichi Saito; Christina Schwarz; Sarah Walters; Koji Nozato; Jie Zhang; Tomoaki Kawakami; William Fischer; Lisa R Latchney; Jennifer J Hunter; Mina M Chung; David R Williams
Journal:  Proc Natl Acad Sci U S A       Date:  2017-01-03       Impact factor: 11.205

6.  Optical coherence angiography.

Authors:  Shuichi Makita; Youngjoo Hong; Masahiro Yamanari; Toyohiko Yatagai; Yoshiaki Yasuno
Journal:  Opt Express       Date:  2006-08-21       Impact factor: 3.894

7.  Adaptive optics enhanced simultaneous en-face optical coherence tomography and scanning laser ophthalmoscopy.

Authors:  David Merino; Chris Dainty; Adrian Bradu; Adrian Gh Podoleanu
Journal:  Opt Express       Date:  2006-04-17       Impact factor: 3.894

8.  The cellular origins of the outer retinal bands in optical coherence tomography images.

Authors:  Ravi S Jonnal; Omer P Kocaoglu; Robert J Zawadzki; Sang-Hyuck Lee; John S Werner; Donald T Miller
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-10-16       Impact factor: 4.799

9.  A dual-modal retinal imaging system with adaptive optics.

Authors:  Alexander Meadway; Christopher A Girkin; Yuhua Zhang
Journal:  Opt Express       Date:  2013-12-02       Impact factor: 3.894

10.  Intraframe motion correction for raster-scanned adaptive optics images using strip-based cross-correlation lag biases.

Authors:  Mehdi Azimipour; Robert J Zawadzki; Iwona Gorczynska; Justin Migacz; John S Werner; Ravi S Jonnal
Journal:  PLoS One       Date:  2018-10-25       Impact factor: 3.240

View more
  6 in total

Review 1.  Cellular-Scale Imaging of Transparent Retinal Structures and Processes Using Adaptive Optics Optical Coherence Tomography.

Authors:  Donald T Miller; Kazuhiro Kurokawa
Journal:  Annu Rev Vis Sci       Date:  2020-07-01       Impact factor: 6.422

2.  Non-interferometric volumetric imaging in living human retina by confocal oblique scanning laser ophthalmoscopy.

Authors:  Wenjun Shao; Ji Yi
Journal:  Biomed Opt Express       Date:  2022-05-24       Impact factor: 3.562

Review 3.  Toward a clinical optoretinogram: a review of noninvasive, optical tests of retinal neural function.

Authors:  Ravi S Jonnal
Journal:  Ann Transl Med       Date:  2021-08

4.  Optoretinogram: optical measurement of human cone and rod photoreceptor responses to light.

Authors:  Mehdi Azimipour; Denise Valente; Kari V Vienola; John S Werner; Robert J Zawadzki; Ravi S Jonnal
Journal:  Opt Lett       Date:  2020-09-01       Impact factor: 3.776

Review 5.  The Development and Clinical Application of Innovative Optical Ophthalmic Imaging Techniques.

Authors:  Palaiologos Alexopoulos; Chisom Madu; Gadi Wollstein; Joel S Schuman
Journal:  Front Med (Lausanne)       Date:  2022-06-30

Review 6.  Optical Coherence Tomography Findings in Rhegmatogenous Retinal Detachment: A Systematic Review.

Authors:  Carla Danese; Paolo Lanzetta
Journal:  J Clin Med       Date:  2022-09-30       Impact factor: 4.964

  6 in total