Literature DB >> 31452970

Hybrid organosilicon/polyol phantom for photoacoustic imaging.

Fulvio Ratto1, Lucia Cavigli1, Claudia Borri1, Sonia Centi1, Giada Magni1, Marina Mazzoni1, Roberto Pini1.   

Abstract

The rapid development of hardware and software for photoacoustic technologies is urging the establishment of dedicated tools for standardization and performance assessment. In particular, the fabrication of anatomical phantoms for photoacoustic imaging remains an open question, as current solutions have not yet gained unanimous support. Here, we propose that a hybrid material made of a water-in-oil emulsion of glycerol and polydimethylsiloxane may represent a versatile platform to host a broad taxonomy of hydrophobic and hydrophilic dyes and recapitulate the optical and acoustic features of bio tissue. For a full optical parameterization, we refer to Wróbel, et al. [ Biomed. Opt. Express7, 2088 (2016)], where this material was first presented for optical imaging. Instead, here, we complete the picture and find that its speed of sound and acoustic attenuation resemble those of pure polydimethylsiloxane, i.e. respectively 1150 ± 30 m/s and 3.5 ± 0.4 dB/(MHz·cm). We demonstrate its use under a commercial B-mode scanner and a home-made A-mode stage for photoacoustic analysis to retrieve the ground-truth encoded in a multilayer architecture containing indocyanine green, plasmonic particles and red blood cells. Finally, we verify the stability of its acoustic, optical and geometric features over a time span of three months.

Entities:  

Year:  2019        PMID: 31452970      PMCID: PMC6701555          DOI: 10.1364/BOE.10.003719

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  3 in total

Review 1.  Criteria for the design of tissue-mimicking phantoms for the standardization of biophotonic instrumentation.

Authors:  Lina Hacker; Heidrun Wabnitz; Antonio Pifferi; T Joshua Pfefer; Brian W Pogue; Sarah E Bohndiek
Journal:  Nat Biomed Eng       Date:  2022-05-27       Impact factor: 25.671

Review 2.  Review of consensus test methods in medical imaging and current practices in photoacoustic image quality assessment.

Authors:  Jorge Palma-Chavez; T Joshua Pfefer; Anant Agrawal; Jesse V Jokerst; William C Vogt
Journal:  J Biomed Opt       Date:  2021-09       Impact factor: 3.170

3.  Photoacoustic imaging phantoms for assessment of object detectability and boundary buildup artifacts.

Authors:  Jorge Palma-Chavez; Keith A Wear; Yash Mantri; Jesse V Jokerst; William C Vogt
Journal:  Photoacoustics       Date:  2022-03-21
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.