| Literature DB >> 31450630 |
Shiming Liu1,2,3, Xinxin Ding4,5, Xiaoke Li6,7, Yongjian Liu8, Shunbo Zhao5.
Abstract
This paper studies the effect of high-strength steel fiber reinforced concrete (SFRC) on the axial compression behavior of rectangular-sectional SFRC-filled steel tube columns. The purpose is to improve the integrated bearing capacity of these composite columns. Nine rectangular-sectional SFRC-filled steel tube columns and one normal concrete-filled steel tube column were designed and tested under axial loading to failure. The compressive strength of concrete, the volume fraction of steel fiber, the type of internal longitudinal stiffener and the spacing of circular holes in perfobond rib were considered as the main parameters. The failure modes, axial load-deformation curves, energy dissipation capacity, axial bearing capacity, and ductility index are presented. The results identified that steel fiber delayed the local buckling of steel tube and increased the ductility and energy dissipation capacity of the columns when the volume fraction of steel fiber was not less than 0.8%. The longitudinal internal stiffening ribs and their type changed the failure modes of the local buckling of steel tube, and perfobond ribs increased the ductility and energy dissipation capacity to some degree. The compressive strength of SFRC failed to change the failure modes, but had a significant impact on the energy dissipation capacity, bearing capacity, and ductility. The predictive formulas for the bearing capacity and ductility index of rectangular-sectional SFRC-filled steel tube columns are proposed to be used in engineering practice.Entities:
Keywords: axial compression; bearing capacity; ductility; energy dissipation capacity; perfobond rib; rectangular-sectional concrete-filled steel tube column; steel fiber reinforced concrete; steel plate rib
Year: 2019 PMID: 31450630 PMCID: PMC6747621 DOI: 10.3390/ma12172716
Source DB: PubMed Journal: Materials (Basel) ISSN: 1996-1944 Impact factor: 3.623
Mix proportions of normal concrete and steel fiber reinforced concrete (SFRC).
| Identifier | Cement (kg/m3) | Slag Powder (kg/m3) | Water (kg/m3) | Sand (kg/m3) | Coarse Aggregate (kg/m3) | Steel Fiber (kg/m3) | Water Reducer (kg/m3) |
|---|---|---|---|---|---|---|---|
| CF60/1.2 | 583.3 | 0 | 175 | 754.4 | 865.9 | 94.2 | 5.9 |
| C70/0 | 546.6 | 60.7 | 175 | 605.0 | 1030.2 | 0 | 7.3 |
| CF70/1.2 | 543.1 | 60.3 | 175 | 769.7 | 885.4 | 94.2 | 7.3 |
| CF80/0.8 | 544.0 | 136.0 | 170 | 732.8 | 949.2 | 62.8 | 0.3 |
| CF80/1.2 | 544.0 | 136.0 | 170 | 775.3 | 892.5 | 94.2 | 0.3 |
| CF80/1.6 | 544.0 | 136.0 | 170 | 835.5 | 816.6 | 125.6 | 0.3 |
Figure 1Details of columns with stiffeners (dimensions in mm). (a) Vertical view of perfobond ribs; (b) vertical view of steel plate ribs; (c) cross section of perfobond ribs; (d) cross section of steel plate ribs. Unit: mm.
Mechanical properties and stiffener of the specimens.
| Specimen ID |
| Stiffener Type | Hole Space(mm) | Volume Fraction of Steel Fiber (%) | ||
|---|---|---|---|---|---|---|
| A-120-CF80/1.2 | 88.0 | 54.6 | 0.45 | Perfobond rib | 120 | 1.2 |
| A-90-CF80/1.2 | 82.0 | 51.3 | 0.48 | 90 | 1.2 | |
| A-60-CF80/1.2 | 82.0 | 51.3 | 0.48 | 60 | 1.2 | |
| A-60-CF80/0.8 | 85.3 | 53.2 | 0.47 | 60 | 0.8 | |
| A-60-CF80/1.6 | 83.0 | 51.9 | 0.48 | 60 | 1.6 | |
| A-60-CF60/1.2 | 59.7 | 38.3 | 0.65 | 60 | 1.2 | |
| A-60-CF70/1.2 | 81.7 | 51.2 | 0.49 | 60 | 1.2 | |
| A-60-C70/0 | 71.7 | 45.5 | 0.55 | 60 | 0 | |
| B-0-CF80/1.2 | 75.0 | 47.4 | 0.53 | Steel plate rib | - | 1.2 |
| C-0-CF80/1.2 | 84.3 | 52.6 | 0.47 | No rib | - | 1.2 |
Figure 2Test setup. (a) Photograph; (b) diagrammatic view.
Figure 3Failure modes of typical specimens. (a) A-60-CF70/1.2; (b) B-0-CF80/1.2; (c) C-0-CF80/1.2.
Figure 4Appearances of the responding rectangular-section. (a) Stiffened specimen; (b) unstiffened specimen.
Figure 5Damage degree of concrete core. (a) A-60-CF70/1.2; (b) B-0-CF80/1.2; (c) C-0-CF80/1.2.
Figure 6Axial load-deformation curves with varying hole spacing.
Figure 7Axial load-deformation curves with a varying volume fraction of steel fiber.
Figure 8Axial load-deformation curves with a varying stiffener type.
Main test results of 10 specimens.
| Specimen | ( | ( | ( | |||||
|---|---|---|---|---|---|---|---|---|
| A-120-CF80/1.2 | 7488.3 | 3.1 | 1.927 | 36.77 | 7395.6 | 1.013 | 1.857 | 1.037 |
| A-90-CF80/1.2 | 7040.6 | 3.1 | 1.932 | 34.52 | 6971.5 | 1.010 | 1.868 | 1.034 |
| A-60-CF80/1.2 | 7050.6 | 3.2 | 1.951 | 35.65 | 6971.5 | 1.011 | 1.884 | 1.036 |
| A-60-CF80/0.8 | 7257.6 | 3.3 | 1.858 | 35.43 | 7215.7 | 1.006 | 1.774 | 1.047 |
| A-60-CF80/1.6 | 7121.7 | 3.3 | 1.986 | 37.67 | 7048.8 | 1.010 | 1.976 | 1.005 |
| A-60-CF60/1.2 | 5288.4 | 2.9 | 2.115 | 26.84 | 5300.0 | 0.998 | 2.035 | 1.039 |
| A-60-CF70/1.2 | 7029.1 | 3.2 | 1.951 | 35.53 | 6958.7 | 1.010 | 1.886 | 1.035 |
| A-60-C70/0 | 6212.2 | 3.1 | 1.652 | 24.90 | 6225.3 | 0.998 | 1.669 | 0.990 |
| B-0-CF80/1.2 | 6827.6 | 3.5 | 1.718 | 32.70 | 6663.8 | 1.025 | 1.921 | 0.894 |
| C-0-CF80/1.2 | 6853.9 | 3.4 | 1.749 | 33.63 | 6951.9 | 0.986 | 1.863 | 0.939 |
Figure 9Changes of bearing capacity with concrete strength.
Figure 10Ultimate load changed with the volume fraction of steel fiber.
Figure 11Changes of ductility index with the hole spacing of perfobond ribs.
Figure 12Changes of ductility index with the volume fraction of steel fiber.