Literature DB >> 31448209

Comparison of three undersampling approaches in computed tomography reconstruction.

Chenyang Shen1, Yifei Lou2, Liyuan Chen1, Tieyong Zeng3, Michael K Ng4, Lei Zhu5, Xun Jia1.   

Abstract

BACKGROUND: Projection data undersampling is an effective approach to reduce X-ray radiation dose in computed tomography (CT). In modern CT technologies, undersampling is also a favorable method to reduce projection data size to facilitate rapid CT scan and imaging. It is an intriguing question that given an undersampling ratio, what is the optimal undersampling approach that enables the best CT image reconstruction. While this is in general a challenging mathematical question, it is the motivation of this paper to compare three types of undersampling operations, which we hope to shed some light to this question.
METHODS: We considered regular view undersampling that acquires X-ray projections at equiangular projection angles, regular ray undersampling that acquires projections at all angles but with X-ray lines blocked within each projection under a periodic pattern, and random ray undersampling that acquires each X-ray line with a certain probability. By representing the undersampling projection operators under the basis of singular vectors of full projection operator, we generated matrix representations of these undersampling operators and numerically perform singular value decomposition (SVD). Singular value spectra and singular vectors were compared.
RESULTS: For a given undersampling ratio, the random ray undersampling approach preserves the properties of the full projection operator better than the other two approaches. This translates to advantages of reconstructing a CT image at a lower error, which has also been demonstrated in the numerical experiments.
CONCLUSIONS: We compared three undersampling strategies and found that random undersampling preserves the most information and outperforms the other two in terms of reconstruction quality.

Entities:  

Keywords:  Computed tomography (CT) reconstruction; dose reduction; iterative reconstruction; singular value decomposition (SVD); undersampling

Year:  2019        PMID: 31448209      PMCID: PMC6685809          DOI: 10.21037/qims.2019.07.07

Source DB:  PubMed          Journal:  Quant Imaging Med Surg        ISSN: 2223-4306


  25 in total

1.  Dose reduction in CT by anatomically adapted tube current modulation. I. Simulation studies.

Authors:  M Gies; W A Kalender; H Wolf; C Suess
Journal:  Med Phys       Date:  1999-11       Impact factor: 4.071

2.  Fast and exact 2D image reconstruction by means of Chebyshev decomposition and backprojection.

Authors:  T Bortfeld; U Oelfke
Journal:  Phys Med Biol       Date:  1999-04       Impact factor: 3.609

3.  Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation.

Authors:  Tobias F Jakobs; Christoph R Becker; Bernd Ohnesorge; Thomas Flohr; Christoph Suess; Uwe J Schoepf; Maximilian F Reiser
Journal:  Eur Radiol       Date:  2002-02-21       Impact factor: 5.315

4.  A prototype table-top inverse-geometry volumetric CT system.

Authors:  Taly Gilat Schmidt; Josh Star-Lack; N Robert Bennett; Samuel R Mazin; Edward G Solomon; Rebecca Fahrig; Norbert J Pelc
Journal:  Med Phys       Date:  2006-06       Impact factor: 4.071

5.  Scatter correction method for X-ray CT using primary modulation: theory and preliminary results.

Authors:  Lei Zhu; N Robert Bennett; Rebecca Fahrig
Journal:  IEEE Trans Med Imaging       Date:  2006-12       Impact factor: 10.048

6.  Scanning-beam digital x-ray (SBDX) technology for interventional and diagnostic cardiac angiography.

Authors:  Michael A Speidel; Brian P Wilfley; Josh M Star-Lack; Joseph A Heanue; Michael S Van Lysel
Journal:  Med Phys       Date:  2006-08       Impact factor: 4.071

7.  Scatter correction for cone-beam CT in radiation therapy.

Authors:  Lei Zhu; Yaoqin Xie; Jing Wang; Lei Xing
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

8.  Dose reduction in CT by anatomically adapted tube current modulation. II. Phantom measurements.

Authors:  W A Kalender; H Wolf; C Suess
Journal:  Med Phys       Date:  1999-11       Impact factor: 4.071

Review 9.  Techniques and applications of automatic tube current modulation for CT.

Authors:  Mannudeep K Kalra; Michael M Maher; Thomas L Toth; Bernhard Schmidt; Bryan L Westerman; Hugh T Morgan; Sanjay Saini
Journal:  Radiology       Date:  2004-10-21       Impact factor: 11.105

10.  Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization.

Authors:  Emil Y Sidky; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2008-08-13       Impact factor: 3.609

View more
  1 in total

1.  A prior image constraint robust principal component analysis reconstruction method for sparse segmental multi-energy computed tomography.

Authors:  Bin Li; Ning Luo; Anni Zhong; Yongbao Li; Along Chen; Linghong Zhou; Yuan Xu
Journal:  Quant Imaging Med Surg       Date:  2021-09
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.