| Literature DB >> 31443221 |
Cancan Zhu1,2, Anzhong Hu1, Junsheng Cui1, Ke Yang1, Xinchao Zhu1,2, Yong Liu1, Guoqing Deng1, Ling Zhu3.
Abstract
Point-of-care (POC) molecular diagnostics play a crucial role in the prevention and treatment of infectious diseases. It is necessary to develop portable, easy-to-use, inexpensive and rapid molecular diagnostic tools. In this study, we proposed a lab-on-a-chip device that integrated DNA extraction, solid-phase PCR and genotyping detection. The ingenious design of the pneumatic microvalves enabled the fluid mixing and reagent storage to be organically combined, significantly reducing the size of the chip. The solid oligonucleotide array incorporated into the chip allowed the spatial separation of the primers and minimized undesirable interactions in multiplex amplification. As a proof-of-concept for POC molecular diagnostics on the device, five genotypes of high-risk human papillomavirus (HPV) (HPV16/HPV18/HPV31/HPV33/HPV58) were examined. Positive quality control samples and HPV patient cervical swab specimens were analyzed on the integrated microdevice. The platform was capable of detection approximately 50 copies of HPV virus per reaction during a single step, including DNA extraction, solid-phase PCR and genotype detection, in 1 h from samples being added to the chip. This simple and inexpensive microdevice provided great utility for the screening and monitoring of HPV genotypes. The sample-to-result platform will pave the way for wider application of POC molecular testing in the fields of clinical diagnostics, food safety, and environmental monitoring.Entities:
Keywords: Lab-on-a-chip device; POC; high-risk HPV genotypes; molecular diagnosis
Year: 2019 PMID: 31443221 PMCID: PMC6722547 DOI: 10.3390/mi10080537
Source DB: PubMed Journal: Micromachines (Basel) ISSN: 2072-666X Impact factor: 2.891
Figure 1A schematic of the microdevice chip: (a) Top view of the chip; (b) The on-chip peristaltic pump consisted of three valves; (c) Solenoid valves for controlling the air circuit (on-off); (d) A photograph of the chip fabricated with polydimethylsiloxane (PDMS).
Figure 2A schematic of the integrated microfluidic chip used for genotyping high-risk human papillomavirus (HPV) strains from clinical samples.
Figure 3DNA was extracted on the integrated chip from different concentrations of the positive quality control HPV58 by real-time PCR.
Figure 4The sensitivity of the integrated chip for the detection of the five positive control HPV genotypes. (a) The fluorescence intensities of the different concentrations obtained by gradient dilution of the positive control sample HPV31 on the integrated chip for DNA extraction and SP-PCR. (b) Serial 10-fold dilutions of the five positive HPV genotypes at specific concentrations were used as templates for on-chip DNA extraction and SP-PCR.
Figure 5The specificity of the integrated chip for the genotyping of HPV16, 18, 31, 33, and 58.
Figure 6Multiplex detection of HPV genotypes from twenty clinical cervical swabs by the integrated array chip.
The HPV genotypes of twenty clinical samples detected by the chip and by real-time PCR.
| Sample | HPV Genotype on Integrated Chip | HPV Genotype by Real-Time PCR (Ct/LightCycle96) | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| HPV16 | HPV18 | HPV31 | HPV33 | HPV58 | HPV16 | HPV18 | HPV31 | HPV33 | HPV58 | |
| 1 | + | − | − | − | − | 32.91 | − | − | − | − |
| 2 | + | − | − | − | − | 36.97 | − | − | − | − |
| 3 | − | + | − | − | − | − | 24.98 | − | − | − |
| 4 | − | + | − | − | − | − | 27.57 | − | − | − |
| 5 | − | − | + | − | − | − | − | 33.65 | − | − |
| 6 | − | − | + | − | − | − | − | 35.79 | − | − |
| 7 | − | − | + | − | − | − | − | 19.47 | − | − |
| 8 | − | − | + | − | − | − | − | 25.37 | − | − |
| 9 | − | − | + | − | − | − | − | 33.68 | − | − |
| 10 | − | − | − | + | − | − | − | − | 22.10 | − |
| 11 | − | − | − | + | − | − | − | − | 27.66 | − |
| 12 | − | − | − | + | − | − | − | − | 36.92 | − |
| 13 | − | − | − | + | − | − | − | − | 33.27 | − |
| 14 | − | − | − | + | − | − | − | − | 32.91 | − |
| 15 | − | − | − | − | + | − | − | − | − | 27.98 |
| 16 | − | − | − | − | + | − | − | − | − | 33.89 |
| 17 | − | − | − | − | − | − | − | − | − | − |
| 18 | − | − | − | − | − | − | − | − | − | − |
| 19 | − | − | − | − | − | − | − | − | − | − |
| 20 | − | − | − | − | − | − | − | − | − | − |