OBJECTIVES: To evaluate the biological and mechanical complications of angulated abutments on full-arch and partial jaw rehabilitations with a follow-up for at least 1 year.
METHODS: Electronic search was carried out in MEDLINE, EMBASE and Web of Science. Studies published between January 2000 and January 2019 were included. The quality of the included studies was assessed. The data extraction was focused on implant loss, marginal bone loss and mechanical complications, and meta-analyses were performed for marginal bone loss, mechanical complications and implant failure.
RESULTS: Nine studies, three prospective and six retrospective cohort studies were included. They reported on 797 patients that received 4127 implants. The total number of abutments was 4079 of which 1673 were angulated, and 2406 were straight. All abutments were prefabricated. Angulated abutments were associated with increased implant failure rates (two studies; RR = 7.30; 95% CI = 2.79-19.08) and an effect that was both statistically significant (P < .001) and clinically relevant. Three studies reported differentiated data for mechanical and technical complications at 1 year of follow-up, being mostly related to the retention screw while screw fracture. Angulated abutments were associated with a statistically significant increase in MBL 1 year after insertion compared to straight abutments (three studies; MD = 0.08 mm; 95% CI = 0.01-0.14 mm; P = .02), which might be, however, clinically negligible.
CONCLUSIONS: The prosthetic complications such as screw loosening and abutment loosening were frequent. After 1 year of follow-up, implants supporting angulated abutments yielded significantly more marginal bone loss than those supporting straight abutments.
© 2019 John Wiley & Sons Ltd.

Entities:  

Keywords:  FDPs; axial load; complications; fixed dental prosthesis; implant dentistry; non-axial load; prosthetic dentistry; systematic review

Mesh:

Substances:

Year:  2019        PMID: 31441527     DOI: 10.1111/joor.12877

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  2 in total

1.  Stress distribution around different abutments on titanium and CFR-PEEK implant with different prosthetic crowns under parafunctional loading: A 3D FEA study.

Authors:  Akanksha Mourya; Rajvi Nahar; Sunil Kumar Mishra; Ramesh Chowdhary
Journal:  J Oral Biol Craniofac Res       Date:  2021-03-16

2.  Er:YAG laser removal of zirconia crowns on titanium abutment of dental implants: an in vitro study.

Authors:  Pingping Cai; Yingying Zhuo; Jie Lin; Zhiqiang Zheng
Journal:  BMC Oral Health       Date:  2022-09-12       Impact factor: 3.747

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.